Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials

被引:0
作者
Hanadi ALamfon [1 ]
Ibrahim MHamouda [2 ,3 ]
机构
[1] Maxillofacial and Oral Rehabilitation Department, Umm Al-Qura University
[2] Conservative Dentistry, Faculty of Dentistry, Umm Al-Qura University
[3] Dental Biomaterials, Faculty of Dentistry, Mansoura University
关键词
denture distortion; flange discrepancy; acrylic resin; occlusal discrepancies; denture base;
D O I
暂无
中图分类号
R783.1 [牙科材料学];
学科分类号
080502 ;
摘要
This study was conducted to investigate the maxillary denture bases and occlusal discrepancies using the Vertex Thermosens in comparison with the conventional polymethyl-methacrylate materials. Twenty maxillary denture bases were prepared from the Vertex ThermoSens and a conventional heat-cured denture base materials. Acrylic maxillary second molars were arranged in their respective positions on the ridge. After curing of both types of denture bases, they were deflasked with their respective master casts. Reference points were prepared for measurements of the antero-posterior and cross-arch dimensions at the denture borders using caliper device. Furthermore, the teeth discrepancies were measured between reference points in the ligual aspect of the second maxillary molars. The recorded data was analyzed using SPSS statistical software version 20. The results showed initial shrinkage of both denture bases in the antero-posterior and cross-arch dimensions immediately after decasting. This contraction was compensated gradually during storage in water up to 2 weeks. Regarding the variable time, there was a significant difference between the tested materials. Moreover, the results revealed occlusal discrepancies and shifting of teeth inward immediately after decasting, followed by outward movement after storage in water for 2 weeks. Regarding the variables time and materials, there were significant differences. Both materials exhibited inward shrinkage in the antero-posterior and cross-arch dimensions immediately after decasting. Both denture bases showed inward shifting of teeth immediately after decasting, followed by outward movement after storage in water up to 2 weeks.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 18 条
[11]  
Influence of storage period and effect of different brands of acrylic resin on the dimensional accuracy of the maxillary denture base. Miéssi Ana Carolina,Goiato Marcelo Coelho,dos Santos Daniela Micheline,Dekon Stefan Fiúza de Carvalho,Okida Ricardo Coelho. Brazilian dental journal . 2008
[12]  
Color stability water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture. Jang DE,Lee JY,Jang HS et al. J Adv Prosthodont . 2015
[13]  
The comparison of denture-base processing techniques. Part I. Material characteristics. Curtis M. Becker,Dale E. Smith,Jack I. Nicholls. The Journal of Prosthetic Dentistry . 1977
[14]  
Effect of different curing temperatures on the distortion at the posterior peripheral seal: an in vitro study. Pasam Nirmala,Hallikerimath R B,Arora Aman,Gilra Shilpi. Indian journal of dental research : official publication of Indian Society for Dental Research . 2012
[15]  
Phillip’’s science of dental materials. Anusavice KJ. . 2006
[16]  
Craig’’s restorative dental materials. Craig RG. . 2006
[17]  
Effect of arch form and water sorption on the palatal base adaptation of probase hot versus the conventional heat cured acrylic resin. Hamouda IM,El-Shokouki AH,Gomaa AM, et al. Int J Dentistry Oral Sci . 2016
[18]  
The Netherlands. Vertex Dental BV. www.vertexthermosens.com .