We introduced the hydrophilic groups to acrylic bone cement to improve compliance and achieve more interdigitation between the bone and the acrylic bone cement in order to create better substrates for immediate loading. FTIR-ATR, contact angle, and maximum breach torque were employed for measurement. The results reveal that the introduction of hydrophilic functional groups has increased PMMA’s surface hydrophilicity after contact angle test. FTIR-ATR results suggest the hydrophilic groups participate in the polymerization reactions, and maximum breach torque of the hydrophilic acrylic bone cements is near 110 Ncm torque. Those effects make it possible for conventional acrylic bone cement application in immediate loading of dental implant.
引用
收藏
页码:627 / 633
页数:7
相关论文
共 11 条
[1]  
Effect of hydrophilic–hydrophobic balance on biocompatibility of poly(methyl methacrylate) (PMMA)–hydroxyapatite (HA) composites[J] . Teodora Gratiela Tihan,Mioara Daniela Ionita,Roxana Gabriela Popescu,Dana Iordachescu.Materials Chemistry and Physics . 2009 (2)
[2]   Polymethylmethacrylate particles inhibit osteoblastic differentiation of MC3T3-E1 osteoprogenitor cells [J].
Chiu, Richard ;
Ma, Ting ;
Smith, R. Lane ;
Goodman, Stuart B. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (07) :932-936
[3]  
A Pilot Study of Complete Edentulous Rehabilitation with Immediate Function Using a New Implant Design: Case Series[J] . PauloMaló,MiguelDe Araújo Nobre,UlrikaPetersson,StinaWigren.Clinical Implant Dentistry and Related Research . 2006 (4)
[4]   Current concepts and techniques in percutaneous vertebroplasty [J].
Heran, Manraj K. S. ;
Legiehn, Gerald M. ;
Munk, Peter L. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2006, 37 (03) :409-+
[5]   Significance of primary stability for osseointegration of dental implants [J].
Lioubavina-Hack, N ;
Lang, NP ;
Karring, T .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (03) :244-250
[6]  
Predicting osseointegration by means of implant primary stability[J] . RabahNedir,MarkBischof,SergeSzmukler‐Moncler,Jean‐PierreBernard,JackySamson.Clinical Oral Implants Research . 2004 (5)
[7]  
Influence of the material constitutive models on the adiabatic shear band spacing: MTS, power law and Johnson–Cook models[J] . L. Daridon,O. Oussouaddi,S. Ahzi.International Journal of Solids and Structures . 2004 (11)
[8]  
Early loading of endosseous implants in the augmented maxilla: a 1‐year prospective study[J] . Gerry M.Raghoebar,PieterSchoen,Henny J. A.Meijer,KeesStellingsma,ArjanVissink.Clinical Oral Implants Research . 2003 (6)
[9]   Effect of γ-ray irradiated poly(L-lactide) on the differentiation of mouse osteoblast-like MC3T3-E1 cells [J].
Isama, K ;
Tsuchiya, T .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2002, 13 (02) :153-166
[10]   Biological and mechanical properties of PMMA-based bioactive bone cements [J].
Mousa, WF ;
Kobayashi, M ;
Shinzato, S ;
Kamimura, M ;
Neo, M ;
Yoshihara, S ;
Nakamura, T .
BIOMATERIALS, 2000, 21 (21) :2137-2146