Oral purgative and simethicone before small bowel capsule endoscopy

被引:0
作者
Bruno Joel Ferreira Rosa [1 ]
Mara Barbosa [1 ]
Joana Magalhes [1 ]
Ana Rebelo [1 ]
Maria Joo Moreira [1 ]
José Cotter [1 ]
机构
[1] Gastroenterology Department,Alto Ave Hospital Center-Guimar es,4835-044 Guimar es,Portugal
关键词
Small bowel capsule endoscopy; Bowel preparation; Polyethylene glycol; Simethicone;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
1002 ; 100201 ;
摘要
AIM:To evaluate small bowel cleansing quality,diagnostic yield and transit time,comparing three cleansing protocols prior to capsule endoscopy.METHODS:Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols:patients in Group A underwent a 24 h liquid diet and overnight fasting;patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol(PEG) the evening before the procedure;patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion.Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor,fair,good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization.When there was no agreement between the two endoscopists,the images were reviewed and discussed until a consensus was reached.The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition.The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images.Positive endoscopic findings,gastric emptying time(GET) and small bowel transit time(SBTT) were recorded for each examination.RESULTS:There was a trend favoring Group B in achieving an acceptable(including fair,good or excellent) level of cleansing(Group A:65%;Group B:83.3%;Group C:68.4%) [P = not significant(NS)] and favoring Group C in attaining an excellent level of cleansing(Group A:10%;Group B:16.7%;Group C:21.1%)(P = NS).The number of patients with an adequate cleansing of the small bowel,corresponding to an excellent or good classification,was 5(25%) in Group A,5(27.8%) in Group B and 4(21.1%) in Group C(P = 0.892).Conversely,7 patients(35%) in Group A,3 patients(16.7%) in Group B and 6 patients(31.6%) in Group C were considered to have poor small bowel cleansing(P = 0.417),with significant fluid or debris such that the examination was unreliable.The proportion of patients with a significant amount of bubbles was 50% in Group A,27.8% in Group B and 15.8% in Group C(P = 0.065).This was significantly lower in Group C when compared to Group A(P = 0.026).The mean GET was 27.8 min for Group A,27.2 min for Group B and 40.7 min for Group C(P = 0.381).The mean SBTT was 256.4 min for Group A,256.1 min for Group B and 258.1 min for Group C(P = 0.998).Regarding to the rate of complete examinations,the capsule reached the cecum in 20 patients(100%) in Group A,16 patients(88.9%) in Group B and 17 patients(89.5%) in Group C(P = 0.312).A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A(12 patients),44.4% in Group B(8 patients) and 57.8% in Group C(11 patients)(P = 0.587).CONCLUSION:Preparation with 2 L of PEG before small bowel capsule endoscopy(SBCE) may improve small bowel cleansing and the quality of visualization.Simethicone may further reduce intraluminal bubbles.No significant differences were found regarding GET,SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 18 条
[1]  
Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy[J]. Takafumi Ito,Ken Ohata,Akiko Ono,Hideyuki Chiba,Yosuke Tsuji,Hajime Sato,Nobuyuki Matsuhashi.World Journal of Gastroenterology. 2012(15)
[2]  
A novel cleansing score system for capsule endoscopy[J]. Sung Chul Park,Bora Keum,Jong Jin Hyun,Yeon Seok Seo,Yong Sik Kim,Yoon Tae Jeen,Hoon Jai Chun,Soon Ho Um,Chang Duck Kim,Ho Sang Ryu.World Journal of Gastroenterology. 2010(07)
[3]  
Effect of small bowel preparation with simethicone on capsule endoscopy[J]. You-hong FANG1, Chun-xiao CHEN2, Bing-ling ZHANG2 (1The Children’s Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, China) (2Department of Gastroenterology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, China).Journal of Zhejiang University(Science B:An International Biomedicine & Biotechnology Journal). 2009(01)
[4]   Efficiency of bowel preparation for capsule endoscopy examination:A meta-analysis [J].
Yaron Niv .
World Journal of Gastroenterology, 2008, (09) :1313-1317
[5]   Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility [J].
Wu, Liucheng ;
Cao, Yunfei ;
Liao, Cun ;
Huang, Jiahao ;
Gao, Feng .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2011, 46 (02) :227-235
[6]  
Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey[J] . Emanuele Rondonotti,Marco Soncini,Carlo Girelli,Giovanni Ballardini,Guglielmo Bianchi,Sergio Brunati,Laura Centenara,Pietro Cesari,Claudio Cortelezzi,Simona Curioni,Claudio Gozzini,Renzo Gullotta,Marco Lazzaroni,Marta Maino,Giovanna Mandelli,Nicola Mantovani,Elisabetta Morandi,Carlo Pansoni,Walter Piubello,Rocco Putignano,Renzo Schalling,Maria Tatarella,Federica Villa,Pasquale Vitagliano,Antonio Russo,Dario Cont
[7]  
Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review[J] . Zhuan Liao,Rui Gao,Can Xu,Zhao-Shen Li.Gastrointestinal Endoscopy . 2010 (2)
[8]  
European Society of Gastrointestinal Endoscopy (ESGE): Recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases[J] . S. Ladas,K. Triantafyllou,C. Spada,M. Riccioni,J.-F. Rey,Y. Niv,M. Delvaux,R. de Franchis,G. Costamagna.Endoscopy . 2010 (03)
[9]  
Bowel preparation before small bowel capsule endoscopy: what is the optimal approach?[J] . Jan J. Koornstra.European Journal of Gastroenterology & Hepatology . 2009 (10)
[10]  
Comparison of two schemes of small bowel preparation for capsule endoscopy with polyethylene glycol: a prospective, randomized single-blind study[J] . Alexandros Kantianis,Stephanos Karagiannis,Christos Liatsos,Petros Galanis,Dimitrios Psilopoulos,Roxane Tenta,Nikolaos Kalantzis,Christos Mavrogiannis.European Journal of Gastroenterology & Hepatology . 2009 (10)