Plastic scintillation detectors for precision Time-of-Flight measurements of relativistic heavy ions

被引:0
|
作者
林文健 [1 ]
赵建伟 [1 ]
孙保华 [1 ]
何鎏春 [1 ]
林炜平 [2 ]
刘传业 [1 ]
谷畑勇夫 [1 ]
寺嶋知 [1 ]
田怡 [1 ]
王枫 [1 ]
王萌 [1 ]
张广鑫 [1 ]
章学恒 [2 ]
竺礼华 [1 ]
段利敏 [2 ]
胡荣江 [2 ]
刘忠 [2 ]
鲁辰桂 [2 ]
任培培 [2 ]
盛丽娜 [2 ]
孙志宇 [2 ]
王世陶 [2 ]
王涛峰 [1 ]
徐治国 [2 ]
郑勇 [2 ]
机构
[1] School of Physics and Nuclear Energy Engineering, Beihang University
[2] Institute of Modern Physics, Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
plastic scintillator; Time-of-Flight; time resolution; walk effect correction;
D O I
暂无
中图分类号
TL812 [闪烁探测技术和仪器];
学科分类号
082704 ;
摘要
Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3;mm;and 80×100×3;mm;have been set up at the External Target Facility(ETF), Institute of Modern Physics(IMP). Their time, energy and position responses are measured with the;O primary beam at 400 Me V/nucleon. After off-line corrections for walk effect and position, the time resolutions of the two detectors are determined to be 27 ps(σ) and 36 ps(σ), respectively. Both detectors have nearly the same energy resolution of3.1%(σ) and position resolution of about 3.4 mm(σ). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading the RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [41] A Feasible and Accurate Technique for Determining the Time-of-Flight in Ultrasonic Distance Measurements
    Namas, Tarik
    Dogruel, Murat
    PROCEEDINGS ELMAR-2008, VOLS 1 AND 2, 2008, : 337 - 340
  • [42] Nanocrystalline Lead Halide Perovskites to Boost Time-of-Flight Performance of Medical Imaging Detectors
    Pagano, Fiammetta
    Kral, Jan
    Decka, Katerina
    Pizzichemi, Marco
    Mihokova, Eva
    Cuba, Vaclav
    Auffray, Etiennette
    ADVANCED MATERIALS INTERFACES, 2024, 11 (10)
  • [43] Development of Time-of-flight Measurement System for Carrier Transport Characterization of TlBr Semiconductor Detectors
    Sugai, Yusuke
    Watanabe, Kenichi
    Hasegawa, Sota
    Hitomi, Keitaro
    Nogami, Mitsuhiro
    SENSORS AND MATERIALS, 2024, 36 (01) : 155 - 161
  • [44] Correlating photodetector with current carrying photogate for time-of-flight distance measurements
    Nemecek, A.
    Zach, G.
    Zimmemann, H.
    OPTICAL SENSORS 2008, 2008, 7003
  • [45] Estimation of Timing Resolution for Very Fast Time-Of-Flight Detectors in Monte Carlo Simulations
    Efthimiou, Nikos
    Emond, Elise
    Cawthorne, Chris
    Tsoumpas, Charalampos
    Thielemans, Kris
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [46] Picosecond pulsed beams of light and heavy keV ions at the Time-of-Flight Medium energy ion scattering system at Uppsala University
    Ntemou, Eleni
    Holenak, Radek
    Wessman, Dan
    Primetzhofer, Daniel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 556
  • [47] STRUCTURAL MEASUREMENTS ON SEVERAL ALAMETHICIN PEPTIDES BY THE TIME-OF-FLIGHT CORRELATION TECHNIQUE
    POPPESCHRIEMER, N
    ENS, W
    ONEIL, JD
    SPICER, V
    STANDING, KG
    WESTMORE, JB
    YEE, AA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 143 : 65 - 85
  • [48] Time-of-Flight Measurements in the Jet of a High-Current Vacuum Arc Thruster
    Michaux, Etienne
    Mazouffre, Stephane
    AEROSPACE, 2023, 10 (12)
  • [49] Time-of-flight spin-echo small-angle neutron measurements
    Plomp, J.
    de Haan, V. O.
    Dalgliesh, R. M.
    Langridge, S.
    van Well, A. A.
    PHYSICA B-CONDENSED MATTER, 2007, 397 (1-2) : 76 - 78
  • [50] High sensitivity probe absorption technique for time-of-flight measurements on cold atoms
    A. K. Mohapatra
    C. S. Unnikrishnan