Neutron collimator design of neutron radiography based on the BNCT facility

被引:0
|
作者
杨晓鹏 [1 ]
俞伯祥 [2 ]
李义国 [3 ]
彭旦 [3 ]
鲁谨 [3 ]
张高龙 [1 ]
赵航 [2 ]
章爱武 [2 ]
李春阳 [4 ]
刘万金 [2 ]
胡涛 [2 ]
吕军光 [2 ]
机构
[1] School of Physics and Nuclear Energy Engineering, Beihang University
[2] State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences
[3] China Institute of Atomic Energy
[4] University of South China
基金
中国国家自然科学基金;
关键词
neutron radiography; ICCD camera; thermal neutron collimator; thermal neuron flux; collimation ratio(L/D;
D O I
暂无
中图分类号
O571.56 [中子衍射及其应用];
学科分类号
0827 ; 082701 ;
摘要
For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [11] Design of a mobile neutron radiography installation based on a compact sealed tube neutron generator
    Ma Wei Chao 1
    2Department of Physics
    NuclearScienceandTechniques, 1997, (01) : 53 - 55
  • [12] Design of the thermal neutron beam for neutron radiography at the Syrian MNSR
    Shaaban, Ismail
    ANNALS OF NUCLEAR ENERGY, 2010, 37 (11) : 1588 - 1594
  • [13] Upgrading the Neutron Radiography Facility in South Africa (SANRAD): Concrete Shielding Design Characteristics
    de Beer, F. C.
    Radebe, M. J.
    Schillinger, B.
    Nshimirimana, R.
    Ramushu, M. A.
    Modise, T.
    PROCEEDINGS OF THE 10TH WORLD CONFERENCE ON NEUTRON RADIOGRAPHY (WCNR-10), 2015, 69 : 115 - 123
  • [14] Simulation and design of a fast neutron radiography detector based on MCP
    Ma, Z. -W.
    Li, W. -M.
    Ran, J. -L.
    Huang, Z. -W.
    Zhang, S. -J.
    Li, K. -J.
    Yao, Z. -E.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [15] A transportable neutron radiography system based on a SbBe neutron source
    Fantidis, J. G.
    Nicolaou, G. E.
    Tsagas, N. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03): : 806 - 810
  • [16] Development of a Small-Aperture Slit System for a High Collimator Ratio at the Thermal Neutron Radiography Facility in JRR-3
    Yasuda, Ryo
    Nojima, Takehiro
    Iikura, Hiroshi
    Sakai, Takuro
    Matsubayashi, Masahito
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2011, 48 (07) : 1094 - 1101
  • [17] Neutron radiography and tomography facility at IBR-2 reactor
    Kozlenko D.P.
    Kichanov S.E.
    Lukin E.V.
    Rutkauskas A.V.
    Belushkin A.V.
    Bokuchava G.D.
    Savenko B.N.
    Physics of Particles and Nuclei Letters, 2016, 13 (3) : 346 - 351
  • [18] Thermal N eutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor
    Soltes, Jaroslav
    Viererbl, Ladislav
    Lahodova, Zdena
    Koleska, Michal
    Vins, Miroslav
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [19] Conceptual design of a thermal neutron radiography facility in the cyclotron 30 LC using the MCNPX code
    Shaaban, Ismail
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2017, 55 (02) : 135 - 144
  • [20] Conceptual design of the INER cyclotron based neutron radiograph facility
    Chia, WM
    Chen, CS
    Yeh, TR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 27 - 31