Neutron collimator design of neutron radiography based on the BNCT facility

被引:0
|
作者
杨晓鹏 [1 ]
俞伯祥 [2 ]
李义国 [3 ]
彭旦 [3 ]
鲁谨 [3 ]
张高龙 [1 ]
赵航 [2 ]
章爱武 [2 ]
李春阳 [4 ]
刘万金 [2 ]
胡涛 [2 ]
吕军光 [2 ]
机构
[1] School of Physics and Nuclear Energy Engineering, Beihang University
[2] State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences
[3] China Institute of Atomic Energy
[4] University of South China
基金
中国国家自然科学基金;
关键词
neutron radiography; ICCD camera; thermal neutron collimator; thermal neuron flux; collimation ratio(L/D;
D O I
暂无
中图分类号
O571.56 [中子衍射及其应用];
学科分类号
0827 ; 082701 ;
摘要
For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [1] Neutron collimator design of neutron radiography based on the BNCT facility
    Yang Xiao-Peng
    Yu Bo-Xiang
    Li Yi-Guo
    Peng Dan
    Lu Jin
    Zhang Gao-Long
    Zhao Hang
    Zhang Ai-Wu
    Li Chun-Yang
    Liu Wan-Jin
    Hu Tao
    Lu Jun-Guang
    CHINESE PHYSICS C, 2014, 38 (02)
  • [2] Design of moderator and collimator for compact neutron radiography systems
    Li, Huanyu
    Zhao, Chenyi
    Qiao, Shuang
    Zhang, Tian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 959 (959):
  • [3] Design of a neutron radiography facility at the spallation source SINQ
    Lehmann, E
    Pleinert, H
    Wiezel, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 11 - 15
  • [4] Thermal Neutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor
    Soltes, Jaroslav
    Viererbl, Ladislav
    Lahodova, Zdena
    Koleska, Michal
    Vins, Miroslav
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1640 - 1644
  • [5] Optimization study of some neutron imaging parameters in a reactor based neutron radiography facility
    Rezazadeh, M.
    Jafari, H.
    Feghhi, S. A. H.
    Omidi, Z.
    Gholamzadeh, Z.
    PROGRESS IN NUCLEAR ENERGY, 2016, 87 : 20 - 25
  • [6] A Monte Carlo evaluation of neutron images quality in a research reactor based neutron radiography facility
    Jafari, H.
    Dastjerdi, M. H. Choopan
    Moghadam, S. Rajabi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976
  • [7] Design of a novel compact neutron collimator
    Bedogni, R.
    Costa, M.
    Durisi, E.
    Grazzi, F.
    Lega, A.
    Mafucci, E.
    Menzio, L.
    Monti, V.
    Planell, O. Sans
    Visca, L.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08)
  • [8] Neutron collimator for neutron radiography applications at tangential port of the TRIGA RC-1 reactor
    Rosa, R.
    Andreoli, F.
    Mattoni, M.
    Palomba, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 605 (1-2): : 57 - 61
  • [9] Computational analysis supporting the design of a new beamline for the mines neutron radiography facility
    Wilson, C.
    King, J.
    NEUTRON IMAGING FOR APPLICATIONS IN INDUSTRY AND SCIENCE, 2017, 88 : 331 - 339
  • [10] Moderator-collimator-shielding design for neutron radiography systems using 252Cf
    da Silva, AX
    Crispim, VR
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (02) : 217 - 225