Sawtooth Activity in Ohmically Heated Plasma on HT-7 Tokamak

被引:1
作者
胡立群
石跃江
曾立
卫明生
刘胜侠
机构
关键词
ICRF; LHCD; Sawtooth Activity in Ohmically Heated Plasma on HT-7 Tokamak; HT; MHD; very;
D O I
暂无
中图分类号
TL631 [磁约束装置];
学科分类号
082701 ;
摘要
Sawtooth activity on HT-7 tokamak has been investigated experimentally mainly by using soft x-ray diode array and magnetic probes. Their behaviors and occurrences are correlated closely to the discharge conditions: the electron density Ne, the electron temperature Te, the safety factor qa on plasma boundary and wall condition etc. When central line-averaged electron density Ne(0) is over 2.0×1013cm-3 , major sawtooth activity emerges with a period of up to 6.5 ms and a fluctuation amplitude of up to 2-30 % of SXR radiation signal. In some cases such as the safety factor between 4.2-4.7 and Zeff=3.0-6.0, a monster sawtooth activity often emerges without apparent deterioration of plasma confinement and without major disruption. During these events, abundant MHD phenomena are observed including partial sawtooth oscillations. In this paper, the observed sawtooth behaviors and their dependence on the and their dependence density Ne and wall condition in ohmically heated plasma are introduced, the results are discussed and presented.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 2 条
[1]   Soft x-ray Diode-array Diagnostic System for HT-7 Superconducting Tokamak [J].
胡立群 ;
卫明生 ;
凌必利 ;
方自深 ;
曾立 .
Plasma Science & Technology, 2000, (06) :515-521
[2]  
J. Wesson. Plasma Physics and Controlled Fusion . 1986