Automatic ocular artifact removal from EEG data using a hybrid CAE-RLS approach

被引:0
作者
Wang Zhongmin [1 ,2 ]
Tian Meng [1 ]
Liang Chen [1 ,2 ]
Song Hui [1 ,2 ]
机构
[1] School of Computer Science and Technology,Xi'an University of Posts and Telecommunications
[2] Shaanxi Key Laboratory of Network Data Analysis and Intelligent Processing,Xi'an University of Posts and Telecommunications
基金
中国国家自然科学基金;
关键词
electroencephalography(EEG); electrooculogram(EOG); ocular artifacts(OAs); recursive least squares(RLS); convolutional autoencoder(CAE);
D O I
10.19682/j.cnki.1005-8885.2020.0008
中图分类号
TN911.7 [信号处理]; R318.1 [人工脏器与器官];
学科分类号
0711 ; 080401 ; 080402 ; 080502 ;
摘要
Traditional methods for removing ocular artifacts(OAs) from electroencephalography(EEG) signals often involve a large number of EEG electrodes or require electrooculogram(EOG) as the reference, these constraints make subjects uncomfortable during the acquisition process and increase the complexity of brain-computer interfaces(BCI). To address these limitations, a method combining a convolutional autoencoder(CAE) and a recursive least squares(RLS) adaptive filter is proposed. The proposed method consists of offline and online stages. In the offline stage, the peak and local mean of the four-channel EOG signals are automatically extracted to obtain the CAE model. Once the model is trained, the EOG channels are no longer needed. In the online stage, by using the CAE model to identify the OAs from a single-channel raw EEG signal, the identified OAs and the given raw EEG signal are used as the reference and input for an RLS adaptive filter. Experiments show that the root mean square error(RMSE) of the CAE-RLS algorithm and independent component analysis(ICA) are 1.253 3 and 1.254 6 respectively, and the power spectral density(PSD) curve for the CAE-RLS is similar to the original EEG signal. These experimental results indicate that by using only a couple of EEG channels, the proposed method can effectively remove OAs without parallel EOG records and accurately reconstruct the EEG signal. In addition, the processing time of the CAE-RLS is shorter than that of ICA, so the CAE-RLS algorithm is very suitable for BCI system.
引用
收藏
页码:81 / 91
页数:11
相关论文
共 13 条
[1]  
Two-stage wavelet shrinkage and EEG-EOG signal contamination model to realize quantitative validations for the artifact removal from multiresource biosignals[J] . Balbir Singh,Hiroaki Wagatsuma.Biomedical Signal Processing and Control . 2019
[2]  
Prescription patterns for routine EEG ordering in patients with intracranial hemorrhage admitted to a neurointensive care unit[J] . Mehdi Ghasemi,Muhammad Umer Azeem,Susanne Muehlschlegel,Felicia Chu,Nils Henninger.Journal of Critical Care . 2019
[3]  
Using a multichannel Wiener filter to remove eye-blink artifacts from EEG data[J] . Adam Borowicz.Biomedical Signal Processing and Control . 2018
[4]  
Visual EEG reviewing times with SCORE EEG[J] . Jan Brogger,Tom Eichele,Eivind Aanestad,Henning Olberg,Ina Hjelland,Harald Aurlien.Clinical Neurophysiology Practice . 2018
[5]   Clinical utility of EEG in diagnosing and monitoring epilepsy in adults [J].
Tatum, W. O. ;
Rubboli, G. ;
Kaplan, P. W. ;
Mirsatari, S. M. ;
Radhakrishnan, K. ;
Gloss, D. ;
Caboclo, L. O. ;
Drislane, F. W. ;
Koutroumanidis, M. ;
Schomer, D. L. ;
Trenite, D. Kastelijn-Nolst ;
Cook, Mark ;
Beniczky, S. .
CLINICAL NEUROPHYSIOLOGY, 2018, 129 (05) :1056-1082
[6]  
Automatic ocular artifacts removal in EEG using deep learning[J] . Banghua Yang,Kaiwen Duan,Chengcheng Fan,Chenxiao Hu,Jinlong Wang.Biomedical Signal Processing and Control . 2018
[7]  
Music induced emotion using wavelet packet decomposition—An EEG study[J] . Geethanjali Balasubramanian,Adalarasu Kanagasabai,Jagannath Mohan,N.P. Guhan Seshadri.Biomedical Signal Processing and Control . 2018
[8]  
Decreased Synchronization in Alcoholics Using EEG[J] . R. Cao,H. Deng,Z. Wu,G. Liu,H. Guo,J. Xiang.IRBM . 2017
[9]   Common Methodology for Cardiac and Ocular Artifact Suppression from EEG Recordings by Combining Ensemble Empirical Mode Decomposition with Regression Approach [J].
Patel, Rajesh ;
Gireesan, K. ;
Sengottuvel, S. ;
Janawadkar, M. P. ;
Radhakrishnan, T. S. .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (02) :201-208
[10]  
Real-time EEG artifact correction during fMRI using ICA[J] . Ahmad Mayeli,Vadim Zotev,Hazem Refai,Jerzy Bodurka.Journal of Neuroscience Methods . 2016