A Monte Carlo simulation and setup optimization of output ef f iciency to PGNAA thermal neutron using 252Cf neutrons

被引:0
作者
张金钊 [1 ]
庹先国 [1 ]
机构
[1] Applied Nuclear Techniques in Geoscience Key Laboratory, Chengdu University of Technology
基金
中国国家自然科学基金;
关键词
PGNAA; neutron source; thermal neutron; moderation; reflection;
D O I
暂无
中图分类号
O571.5 [中子物理];
学科分类号
0827 ; 082701 ;
摘要
We present the design and optimization of a prompt γ-ray neutron activation analysis(PGNAA) thermal neutron output setup based on Monte Carlo simulations using MCNP5 computer code. In these simulations, the moderator materials, reflective materials, and structure of the PGNAA252 Cf neutrons of thermal neutron output setup are optimized. The simulation results reveal that the thin layer paraffin and the thick layer of heavy water moderating effect work best for the252 Cf neutron spectrum. Our new design shows a significantly improved performance of the thermal neutron flux and flux rate, that are increased by 3.02 times and 3.27 times, respectively,compared with the conventional neutron source design.
引用
收藏
页码:145 / 149
页数:5
相关论文
共 8 条
  • [1] A compact neutron beam generator system designed for prompt gamma nuclear activation analysis[J] . J. Ghassoun,D. Mostacci.Applied Radiation and Isotopes . 2010 (8)
  • [2] Non-destructive analysis of chlorine in fly ash cement concrete
    Naqvi, A. A.
    Garwan, M. A.
    Nagadi, M. M.
    Maslehuddin, M.
    Al-Amoudi, O. S. B.
    Khateeb-ur-Rehman
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (02) : 446 - 450
  • [3] Performance improvement of keV neutrons-based PGNAA setups
    Naqvi, A. A.
    Abdelmonem, M. S.
    Al-Misned, Ghada
    Al-Ghamdi, Hanan
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1631 - 1636
  • [4] Interferences in Prompt γ Analysis of corrosive contaminants in concrete
    Naqvi, A. A.
    Nagadi, M. M.
    Al-Amoudi, O. S. B.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (03) : 803 - 809
  • [5] A Monte Carlo comparison of PGNAA system performance using 252 Cf neutrons, 2.8-MeV neutrons and 14-MeV neutrons[J] . A.A. Naqvi.Nuclear Inst. and Methods in Physics Research, A . 2003 (3)
  • [6] Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code
    Oliveira, C
    Salgado, J
    [J]. APPLIED RADIATION AND ISOTOPES, 1998, 49 (12) : 1685 - 1689
  • [7] Feasibility of neutron activation methods for measurement of sodium and aluminium in green liquor[J] . R.P. Gardner,P. Guo,Y.Y. Wang,A. Sood,S.H. Lee,C.L. Dobbs.Applied Radiation and Isotopes . 1997 (10)
  • [8] A Monte Carlo study of the influence of the geometry arrangements and structural materials on a PGNAA system performance for cement raw material analysis[J] . Applied Radiation and Isotopes . 1997 (10)