The cavitation in a mechanical heart valve(MHV) is a serious concern. In most of the investigations of the MHV cavitation in vitro, the tap water, the distilled water, or the glycerin are used as the test liquids, instead of the real blood. Therefore, the effects of the liquid properties on the cavitation can not be well revealed. In this paper, the cavitation erosion in the porcine bloods is experimentally investigated as well as in the tap water and the distilled water by means of a vibratory apparatus. The results show that the blood produces a weaker intensity of the cavitation erosion than the tap water or the distilled water. The cavitation erosion decreases with the decrease of the liquid temperature or with the increase of the concentration of the blood, especially with the increase of the liquid viscosity. It is the viscosity that could be a major dominant factor affecting this erosion. The temperature or the concentration of the blood changes the viscosity, and in turns changes the intensity of the cavitation erosion.
引用
收藏
页码:724 / 727
页数:4
相关论文
共 19 条
  • [1] The method of vibration cavitation erosion test. State Standard of the People’’s Republic of China,GB/T 6383- 2009 . 2009
  • [2] Bubble formation on St. Jude Medical mechanical heart valves: an in-vitro study. Milo Simcha,Gutfinger Chaim,Chu Gina Yu-chi,Gharib Morteza. The Journal of heart valve disease . 2003
  • [3] Estimation of mechanical heart valve cavitation in an electro-hydraulic total artificial heart. Lee Hwansung,Taenaka Yoshiyuki,Kitamura Soichro. Artificial Organs . 2006
  • [4] Leaflet fracture in Edwards-Duromedics bileaflet valves. Klepetko W,Moritz A,Mlczoch J,Schurawitzki H,Domanig E,Wolner E. Journal of Thoracic and Cardiovascular Surgery . 1989
  • [5] Evolution of mechanical heart valves
    DeWall, RA
    Qasim, N
    Carr, L
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (05) : 1612 - 1621
  • [6] Leaflet Escape in a New Bileaflet Mechanical Valve: TRI Technologies[J] . Tomaso Bottio,Dino Casarotto,Gaetano Thiene,Luca Caprili,Annalisa Angelini,Gino Gerosa. &nbspCirculation: Journal of the American Heart Association . 2003 (18)
  • [7] Mechanism for Cavitation in the Mechanical Heart Valve With an Artificial Heart: Nuclei and Viscosity Dependence[J] . HwansungLee,YoshiyukiTaenaka,SoichiroKitamura. &nbspArtificial Organs . 2005 (1)
  • [8] A Novel Study of Mechanical Heart Valve Cavitation in a Pressurized Pulsatile Duplicator
    Wu, Changfu
    Retta, Stephen M.
    Robinson, Ronald A.
    Herman, Bruce A.
    Grossman, Laurence W.
    [J]. ASAIO JOURNAL, 2009, 55 (05) : 445 - 451
  • [9] Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing
    Lee, Hwansung
    Homma, Akihiko
    Tatsumi, Eisuke
    Taenaka, Yoshiyuki
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2010, 13 (01) : 17 - 23
  • [10] Cavitation Phenomena in Mechanical Heart Valves: Studied by Using a Physical Impinging Rod System[J] . Chi-Wen Lo,Sheng-Fu Chen,Chi-Pei Li,Po-Chien Lu. &nbspAnnals of Biomedical Engineering . 2010 (10)