Effect of simulated dynamic intraocular pressure on retinal thickness measured by optical coherence tomography after cataract surgery

被引:0
|
作者
Ding Chen [1 ]
Jun Zhu [1 ]
Jin Li [1 ]
Xi-Xia Ding [1 ]
Fan Lu [1 ]
Yun-E Zhao [1 ]
机构
[1] Eye Hospital, Wenzhou Medical College
关键词
intraocular pressure; retina; optical coherence tomography; phacoemulsification;
D O I
暂无
中图分类号
R779.66 [白内障摘除术];
学科分类号
100212 ;
摘要
AIM: To investigate the effect of simulated dynamic intraocular pressure (SDIOP) during uncomplicated phaco- emulsification on postoperative macular and peripapillary retinal nerve fiber layer (RNFL) thickness. METHODS: Macular and RNFL thicknesses in one eye of patients (n =30) undergoing uncomplicated phacoemulsification were measured by optical coherence tomography preoperatively and 1 week postoperatively. The best- corrected visual acuity, SDIOP, irrigation time(IT), effective phacoemulsification time, entire surgical duration, blood pressure, and heart rate were recorded. RESULTS: The mean SDIOP and IT was (74.9±27.4)cmH2O and (178.4±21.6) seconds respectively. We divided our patients into two groups based upon IT with greater than 90cmH2O (P>90IT). In Group A (n = 14), the P>90IT was greater than the mean P>90IT, and in Group B (n=16), the P>90IT was less than the mean P>90IT. For all patients there was a significant increase in macular thickness one week after cataract surgery (P =0.001). While the RNFL thickness tended to increase, the change was not significant. The postoperative macular thickness of Group A,(277.8±13.7)μm, was significantly thicker than that of Group B, (267.9±15.0)μm (P =0.004). The postoperative peripapillary RNFL thickness of Group A, (96.8±10.8)μm, was not significantly different from Group B. For Group A, the change in macular thickness was positively correlated with P>90IT (R 2=0.524,P =0.02). There was no statistical difference in postoperative visual acuity between Groups A and B. CONCLUSION: After uncomplicated phacoemulsification, increased macular thickness is associated with the IT under high SDIOP. The effect of high SDIOP is limited to the sub-clinical level.
引用
收藏
页码:687 / 693
页数:7
相关论文
共 50 条
  • [1] Effect of simulated dynamic intraocular pressure on retinal thickness measured by optical coherence tomography after cataract surgery
    Chen, Ding
    Zhu, Jun
    Li, Jin
    Ding, Xi-Xia
    Lu, Fan
    Zhao, Yun-E
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (06) : 687 - 693
  • [2] Macular Thickness Measured by Optical Coherence Tomography in a Healthy Population Before and After Uncomplicated Cataract Phacoemulsification Surgery
    Cagini, Carlo
    Fiore, Tito
    Iaccheri, Barbara
    Piccinelli, Francesco
    Ricci, Maria Antonietta
    Fruttini, Daniela
    CURRENT EYE RESEARCH, 2009, 34 (12) : 1036 - 1041
  • [3] Macular thickness after uneventful cataract surgery determined by optical coherence tomography
    von Jagow, Burkhard
    Ohrloff, Christian
    Kohnen, Thomas
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) : 1765 - 1771
  • [4] Macular thickness after uneventful cataract surgery determined by optical coherence tomography
    Burkhard von Jagow
    Christian Ohrloff
    Thomas Kohnen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1765 - 1771
  • [5] The effect of age on the response of retinal capillary filling to changes in intraocular pressure measured by optical coherence tomography angiography
    Jiang, Xiaoyun
    Johnson, Elaine
    Cepurna, William
    Lozano, Diana
    Men, Shaojie
    Wang, Ruikang K.
    Morrison, John
    MICROVASCULAR RESEARCH, 2018, 115 : 12 - 19
  • [6] The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography
    El-Ashry, Mohamed
    Appaswamy, Shivashankar
    Deokule, Sunil
    Pagliarini, Sergio
    CURRENT EYE RESEARCH, 2006, 31 (05) : 409 - 413
  • [7] Foveal thickness after cataract surgery - Measurement by optical coherence tomography
    Neumaier-Ammerer, B.
    Schmid, K. E.
    Binder, S.
    SPEKTRUM DER AUGENHEILKUNDE, 2008, 22 (05) : 301 - 304
  • [8] Foveal thickness after cataract surgery – Measurement by optical coherence tomography
    B. Neumaier-Ammerer
    K. E. Schmid
    S. Binder
    Spektrum der Augenheilkunde, 2008, 22 : 301 - 304
  • [9] Evaluation of macular thickness after uncomplicated cataract surgery using optical coherence tomography
    Giansanti, Fabrizio
    Bitossi, Alice
    Giacomelli, Giovanni
    Virgili, Gianni
    Pieretti, Giulia
    Giuntoli, Matteo
    Abbruzzese, Giacomo
    Menchini, Ugo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 751 - 756
  • [10] Prospective Study of Foveal Thickness Alterations after Cataract Surgery Assessed by Optical Coherence Tomography
    Tsilimbaris, Miltiadis
    Diakonis, Vasilios F.
    Kymionis, George D.
    Eleftheriadou, Maria I.
    Fragkiskou, Sofia
    Moschandreas, Joanna
    Frueh, Beatrice E.
    Epstein, Daniel
    Pallikaris, Aristophanis I.
    OPHTHALMOLOGICA, 2012, 228 (01) : 53 - 58