3D Shape Reconstruction of Lumbar Vertebra From Two X-ray Images and a CT Model

被引:0
作者
Longwei Fang [1 ,2 ]
Zuowei Wang [3 ,4 ]
Zhiqiang Chen [1 ,2 ]
Fengzeng Jian [3 ]
Shuo Li [5 ]
Huiguang He [6 ,1 ,2 ,7 ]
机构
[1] the Research Center for Brain-Inspired Intelligence & National Laboratory of Pattern Recognition, Institute of Automation, Chinese Academy of Sciences
[2] the University of Chinese Academy of Sciences
[3] the Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Division of Spine, China International Neurological Institute
[4] Department of Neurosurgery, Beijing Hospital, National Center of Gerontology
[5] the Department of Medical Biophysics, Schulich School of Medical and Dentistry, and also with the Department of Medical Imaging, Schulich School of Medical and Dentistry, University of Western Ontario
[6] IEEE
[7] the Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences
关键词
2D/2D registration; 2D/3D registration; 3D reconstruction; vertebra model; X-ray image;
D O I
暂无
中图分类号
TP391.41 []; R816.8 [外科、骨科];
学科分类号
080203 ; 1001 ; 100105 ; 100207 ; 100602 ;
摘要
Structure reconstruction of 3 D anatomy from biplanar X-ray images is a challenging topic. Traditionally, the elastic-model-based method was used to reconstruct 3 D shapes by deforming the control points on the elastic mesh. However, the reconstructed shape is not smooth because the limited control points are only distributed on the edge of the elastic mesh.Alternatively, statistical-model-based methods, which include shape-model-based and intensity-model-based methods, are introduced due to their smooth reconstruction. However, both suffer from limitations. With the shape-model-based method, only the boundary profile is considered, leading to the loss of valid intensity information. For the intensity-based-method, the computation speed is slow because it needs to calculate the intensity distribution in each iteration. To address these issues, we propose a new reconstruction method using X-ray images and a specimen's CT data. Specifically, the CT data provides both the shape mesh and the intensity model of the vertebra. Intensity model is used to generate the deformation field from X-ray images, while the shape model is used to generate the patient specific model by applying the calculated deformation field.Experiments on the public synthetic dataset and clinical dataset show that the average reconstruction errors are 1.1 mm and1.2 mm, separately. The average reconstruction time is 3 minutes.
引用
收藏
页码:1124 / 1133
页数:10
相关论文
共 22 条
[1]  
Robust Rigid Registration Algorithm Based on Pointwise Correspondence and Correntropy[J] . Shaoyi Du,Guanglin Xu,Sirui Zhang,Xuetao Zhang,Yue Gao,Badong Chen.Pattern Recognition Letters . 2018
[2]  
New iterative closest point algorithm for isotropic scaling registration of point sets with noise[J] . Shaoyi Du,Juan Liu,Bo Bi,Jihua Zhu,Jianru Xue.Journal of Visual Communication and Image Represe . 2016
[3]   Building dynamic population graph for accurate correspondence detection [J].
Du, Shaoyi ;
Guo, Yanrong ;
Sanroma, Gerard ;
Ni, Dong ;
Wu, Guorong ;
Shen, Dinggang .
MEDICAL IMAGE ANALYSIS, 2015, 26 (01) :256-267
[4]  
Towards Multiple 3D Bone Surface Identification and Reconstruction Using Few 2D X-Ray Images for Intraoperative Applications[J] . Simant Prakoonwit.International Journal of Art, Culture and Design Technologies (IJACDT) . 2014 (1)
[5]  
3D reconstruction of the lumbar vertebrae from anteroposterior and lateral dual-energy X-ray absorptiometry[J] . Tristan Whitmarsh,Ludovic Humbert,Luis M. Del Río Barquero,Silvana Di Gregorio,Alejandro F. Frangi.Medical Image Analysis . 2013
[6]  
Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques[J] . Yasser Allam,J. Silbermann,F. Riese,R. Greiner-Perth.European Spine Journal . 2013 (3)
[7]  
A Prospective Multicenter Registry on the Accuracy of Pedicle Screw Placement in the Thoracic, Lumbar, and Sacral Levels With the Use of the O-arm Imaging System and StealthStation Navigation[J] . Erik Van de Kelft,F. Costa,D. Van der Planken,F. Schils.Spine . 2012 (25)
[8]  
2D–3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models[J] . N. Baka,B.L. Kaptein,M. de Bruijne,T. van Walsum,J.E. Giphart,W.J. Niessen,B.P.F. Lelieveldt.Medical Image Analysis . 2011 (6)
[9]   Fast 3D reconstruction of the spine from biplanar radiographs using a deformable articulated model [J].
Moura, Daniel C. ;
Boisvert, Jonathan ;
Barbosa, Jorge G. ;
Labelle, Hubert ;
Tavares, Joao Manuel R. S. .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (08) :924-933
[10]   Construction of 3D human distal femoral surface models using a 3D statistical deformable model [J].
Zhu, Zhonglin ;
Li, Guoan .
JOURNAL OF BIOMECHANICS, 2011, 44 (13) :2362-2368