摘要
For scanning transmission proton microscopy tomography,to compare cell images of the proton stopping power and relative electron density,two cell phantoms are designed and simulated by code FLUKA.The cell images are reconstructed by the filtered back projection algorithm,and compared with their tomography imaging.The images of stopping power and relative electron density slightly vary with proton energies,but the internal images are of clear with high resolution.The organic glass image of relative electron density reveals the resolution power of proton tomography.Also,the simulation results reflect effects of the boundary enhancement,the weak artifacts,and the internal structure border extension by multiple scattering.So using proton tomography to analyze internal structure of a cell is a superior.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 9 条
  • [1] Scanning transmission proton microscopy tomography of reconstruction cells from simulated data
    Zhang Conghua
    Li Min
    Hou Qing
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (02) : 89 - 94
  • [2] A reconstruction approach for proton computed tomography by modeling the integral depth dose of the scanning proton pencil beam
    Chen, Xinyuan
    Medrano, Maria
    Sun, Baozhou
    Hao, Yao
    Reynoso, Francisco J.
    Darafsheh, Arash
    Yang, Deshan
    Zhang, Tiezhi
    Zhao, Tianyu
    MEDICAL PHYSICS, 2022, 49 (04) : 2602 - 2620
  • [3] Image quality of the proton imaging from computer-simulated data
    Zhang Conghua
    Hou Qing
    Gou Chengjun
    Wu Zhangwen
    NUCLEAR SCIENCE AND TECHNIQUES, 2010, 21 (01) : 20 - 23
  • [4] Image quality of the proton imaging from computer-simulated data
    ZHANG Conghua HOU Qing GOU Chengjun WU Zhangwen Key Laboratory of Radiation Physics and Technology
    NuclearScienceandTechniques, 2010, 21 (01) : 20 - 23
  • [5] Reconstruction of 12 MV bremsstrahlung spectra from measured transmission data
    LEI Jia-Rong
    Key Laboratory for Radiation Physics and Technology of Education Ministry of China
    NuclearScienceandTechniques, 2003, (02) : 138 - 143
  • [6] Two-dimensional noise reconstruction in proton computed tomography using distance-driven filtered back-projection of simulated projections
    Raedler, Martin
    Landry, Guillaume
    Rit, Simon
    Schulte, Reinhard W.
    Parodi, Katia
    Dedes, George
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21):
  • [7] Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography
    Bassam Hassan
    Paulo Couto Souza
    Reinhilde Jacobs
    Soraya de Azambuja Berti
    Paul van der Stelt
    Clinical Oral Investigations, 2010, 14 : 303 - 310
  • [8] Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography
    Hassan, Bassam
    Souza, Paulo Couto
    Jacobs, Reinhilde
    Berti, Soraya de Azambuja
    van der Stelt, Paul
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (03) : 303 - 310
  • [9] Comparing stochastic proton interactions simulated using TOPAS-nBio to experimental data from fluorescent nuclear track detectors
    Underwood, T. S. A.
    Sung, W.
    McFadden, C. H.
    McMahon, S. J.
    Hall, D. C.
    McNamara, A. L.
    Paganetti, H.
    Sawakuchi, G. O.
    Schuemann, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08): : 3237 - 3249