Dissolved Air Flotation in Combination with Ultrafiltration Membrane Modules in Surface Water Treatment

被引:0
|
作者
Yulong Shi [1 ,2 ]
Jun Ma [1 ,2 ]
Daoji Wu [3 ]
Qin Pan [4 ]
机构
[1] National Engineering Research Center of Urban Water Resources,Harbin Institute of Technology
[2] Huainan Capital Water Co.,Ltd.
[3] State Key Lab of Urban Water Resource and Environment,Harbin Institute of Technology
[4] School of Municipal and Environmental Engineering,Shandong Jianzhu University
基金
国家高技术研究发展计划(863计划);
关键词
dissolved air flotation; ultrafiltration; particle activated carbon; zeolite; membrane biofouling;
D O I
暂无
中图分类号
TU991.2 [净水工程(给水处理)];
学科分类号
0815 ;
摘要
The primary purpose of this research is to evaluate the feasibility of dissolved air flotation(DAF) as pretreatment process for membrane modules in river water treatment.The performances of DAF in combination with an up-flow membrane biofilter(MBF) and a hollow-fiber ultrafiltration membrane(UFM) were investigated respectively.Removal efficiency of ultraviolet absorbance at 254 nm(UV254),ammonia nitrogen(NH3-N),particle counts and microbial index were measured for both systems.Results showed that DAF was a robust pretreatment process for floc particles separation despite of raw water quality fluctuations.For DAFUFM system,the monitoring data indicated bacteria breeding,nitrite accumulation in membrane vessel and the ammonia concentration of permeate water even exceeded regulatory limits.By contrast,DAF-MBF system was established via the introduction of multilayer filter media between DAF and curtain type ultrafiltration membrane.In MBF,the matured biological activated carbon(BAC) and zeolite particles guaranteed the efficient removal of both organic matters and ammonia.Moreover,the high dissolved oxygen levels in DAF effluent significantly improved bio-adsorption and degradation of pollutants in MBF.The retention of microorganisms by the membrane not only ensured a high concentration of biomass,but also eliminated the risk of microbes leaking out from MBF.In addition,compared with UFM,the curtain membrane exhibited obviously slower fouling development.These results suggested that the DAF-MBF system was more suitable for purifying raw waters seriously polluted by dissolved contaminants.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [1] Dissolved Air Flotation in Combination with Ultrafiltration Membrane Modules in Surface Water Treatment
    Yulong Shi
    Jun Ma
    Daoji Wu
    Qin Pan
    Journal of Harbin Institute of Technology, 2017, 24 (03) : 23 - 30
  • [2] DISSOLVED AIR FLOTATION IN WATER TREATMENT
    MORSE, JJ
    WATER AND WATER ENGINEERING, 1973, 77 (927): : 161 - 164
  • [3] PRODUCTION WATER TREATMENT BY DISSOLVED AIR FLOTATION
    De Turris, Antonio
    Carolina Yabroudi, Suher
    Valbuena, Brenyith
    Gutierrez, Charles
    Cardenas, Carmen
    Herrera, Lenin
    Rojas, Carlos
    INTERCIENCIA, 2011, 36 (03) : 211 - 218
  • [5] Dissolved air flotation model for drinking water treatment
    Shawwa, AR
    Smith, DW
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (02) : 373 - 382
  • [6] APPLICATION OF DISSOLVED AIR FLOTATION IN WATER TREATMENT.
    Bal, A.S.
    Kulkarni, D.N.
    Pathak, B.N.
    1983, (34):
  • [8] POTABLE WATER TREATMENT BY DISSOLVED AIR FLOTATION AND FILTRATION.
    Krofta, Milos
    Wang, Lawrence K.
    1600, (74):
  • [9] Algae laden water treatment by dissolved air flotation (DAF)
    Vlaski, A
    vanBreemen, AN
    Alaerts, GJ
    DISSOLVED AIR FLOTATION, 1997, : 215 - 237
  • [10] POTABLE WATER-TREATMENT BY DISSOLVED AIR FLOTATION AND FILTRATION
    KROFTA, M
    WANG, LK
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1982, 74 (06): : 305 - 310