Experimental study on thermal resistance of fouling in heat exchangers of sewage source heat pumps

被引:0
作者
吴学慧 [1 ]
魏巧兰 [1 ]
孙德兴 [1 ]
机构
[1] School of Municipal and Environmental Engineering,Harbin Institute of Technology
基金
中国国家自然科学基金;
关键词
swage heat exchangers; fouling; model; experiments;
D O I
暂无
中图分类号
TU831 [空气调节];
学科分类号
080705 ;
摘要
To investigate the formation of fouling in sewage heat exchangers,a model of thermal resistance with time is developed based on the experiments in a practical engineering site. And this model is asymptotic exponential function. According to the characteristic of sewage heat exchangers,the effective thermal resistance and effective coefficient of heat transmission during the formation of fouling are defined. A model for pressure loss of fouling of asymptotic distribution is presented based on the model of thermal resistance of fouling. And the maximum absolute margin of error of the fouling thermal resistance is smaller than the typical allowable error range. The maximum relative error of the heat transfer coefficient is 12% . These can meet the requirements of engineering. The results of experiments provide a basis for further study and application of swage heat exchangers.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
[41]   Compact heat exchangers liquid-side fouling [J].
Grillot, JM .
APPLIED THERMAL ENGINEERING, 1997, 17 (8-10) :717-726
[42]   A review of recent advancements in the crystallization fouling of heat exchangers [J].
Shaikh, Kaleemullah ;
Newaz, Kazi Md Salim ;
Zubir, Mohd Nashrul Mohd ;
Wong, Kok Hoe ;
Khan, Wajahat Ahmed ;
Abdullah, Shekh ;
Alam, Md Shadab ;
Sugumaran, Luvindran .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (22) :12369-12392
[43]   Thermal interaction between tunnel ground heat exchangers and borehole heat exchangers [J].
Bidarmaghz, Asal ;
Narsilio, Guillermo A. ;
Buhmann, Patrik ;
Moormann, Christian ;
Westrich, Bernhard .
GEOMECHANICS FOR ENERGY AND THE ENVIRONMENT, 2017, 10 :29-41
[44]   Design of borehole heat exchangers for ground-source heat pumps: A literature review, methodology comparison and analysis on the penalty temperature [J].
Capozza, Antonio ;
De Carli, Michele ;
Zarrella, Angelo .
ENERGY AND BUILDINGS, 2012, 55 :369-379
[45]   An experimental and numerical study of a de-fouling evaporator used in a wastewater source heat pump [J].
Shen, Chao ;
Yang, Liangcheng ;
Wang, Xinlei ;
Jiang, Yiqiang ;
Yao, Yang .
APPLIED THERMAL ENGINEERING, 2014, 70 (01) :501-509
[46]   FOULING ON PLATE-TYPE HEAT-EXCHANGERS USED FOR HEAT STERILIZATION OF FOODS [J].
SHIDARA, H ;
KIKUCHI, M ;
WATANABE, R .
KAGAKU KOGAKU RONBUNSHU, 1994, 20 (01) :1-7
[47]   Dynamic thermal performance of horizontal ground source heat pumps The impact of coupled heat and moisture transfer [J].
Gan, Guohui .
ENERGY, 2018, 152 :877-887
[48]   Detection of changes in fouling behavior by simultaneous monitoring of thermal and hydraulic performance of refinery heat exchangers [J].
Diaz-Bejarano, Emilio ;
Coletti, Francesco ;
Macchietto, Sandro .
12TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING (PSE) AND 25TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING (ESCAPE), PT B, 2015, 37 :1649-1654
[49]   Monitoring fouling in heat exchangers under temperature control based on excess thermal and hydraulic loads [J].
Patil, Parag ;
Srinivasan, Babji ;
Srinivasan, Rajagopalan .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 181 :41-54
[50]   Artificial neural networks for predicting the performance of heat pumps with horizontal ground heat exchangers [J].
Zhou, Yu ;
Narsilio, Guillermo ;
Makasis, Nikolas ;
Soga, Kenichi ;
Chen, Peng ;
Aye, Lu .
FRONTIERS IN ENERGY RESEARCH, 2024, 12