An aviation oxygen supply system based on a mechanical ventilation model

被引:0
作者
Yan SHI [1 ]
Yixuan WANG [1 ]
Maolin CAI [1 ]
Bolun ZHANG [1 ]
Jian ZHU [2 ]
机构
[1] School of Automation Science and Electrical Engineering,Beihang University
[2] Beijing ChaoYang Hospital
关键词
Aviation; Dynamic characteristics; Mathematical modeling; Mechanical ventilation; Oxygen supply system;
D O I
暂无
中图分类号
V245.31 [];
学科分类号
082504 ;
摘要
At high altitudes, an Aviation Oxygen Supply System(AOSS) protects pilots from low pressure and hypoxia by continuously providing oxygen corresponding to the pilots' dynamic respiratory properties.An AOSS mainly consists of oxygen supercharging machines which are used in a high-altitude flight cabin to supply pressurized oxygen to pilots.Therefore, it is of great significance to study the airflow dynamic characteristics of an AOSS for safe, continuous, and efficient oxygen supply.In this paper, an AOSS is firstly simplified and considered as a mechanical ventilation system.Then, its corresponding mathematical model is constructed.Next, to verify the mathematical model, a prototype AOSS with a lung simulator is proposed for an experimental study.Afterwards, to build a foundation for the optimization of the AOSS, the airflow dynamic characteristics of an aircraft are analyzed, and the effects of key parameters on the respiration system are researched.Through experimental and simulation studies, it can be concluded that the mathematical model is effective.Subsequently, for stability during the respiration process, we consider setting the equivalent throttling areas of the inspiration and expiration pipelines smaller within certain limits; additionally, an excessively high oxygen supply pressure will disturb smooth airflow, and in a low-pressure environment, the pressure can be 84 cm H2O lower than the standard atmospheric pressure.This research can be referred to in the design of an oxygen supply system and the study on optimization of airflow dynamic characteristics.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 10 条
[1]  
Study on air flow dynamic characteristic of mechanical ventilation of a lung simulator[J]. NIU JingLong,SHI Yan,CAO ZhiXin,CAI MaoLin,CHEN Wei,ZHU Jian,XU WeiQing.Science China(Technological Sciences). 2017(02)
[2]   飞行员双人高空供氧方案实验评价 [J].
刘晓鹏 ;
肖华军 ;
臧斌 ;
顾昭 ;
王桂友 ;
施维茹 ;
于立华 .
科学技术与工程, 2014, 14 (21) :52-56+62
[3]  
The denitrogenation by breathing oxygen-rich gas to prevent altitude decompression sickness[J]. Hua-jun XIAO,Xiao-peng LIU,Bin ZANG,Gui-you WANG,Zhao GU.中国应用生理学杂志. 2012(06)
[4]   航空供氧系统高空性能参数数值仿真 [J].
余中军 ;
赵竞全 .
北京航空航天大学学报, 2010, (08) :918-921
[5]   基于Simulink的航空供氧系统加压供氧性能仿真 [J].
余中军 ;
赵竞全 .
微计算机应用, 2010, 31 (02) :1-6
[6]   基于呼吸机的人工呼吸系统力学建模与仿真 [J].
易韦韦 ;
张玘 ;
王跃科 ;
覃海燕 .
系统仿真学报, 2009, (15) :4892-4895
[7]  
A control system for mechanical ventilation of passive and active subjects[J] . Fleur T. Tehrani.Computer Methods and Programs in Biomedicine . 2013
[8]  
Particle-Imaging Techniques for Experimental Fluid Mechanics[J] . R J Adrian.Annual Review of Fluid Mechanics . 1991
[9]  
A New Oxygen Mask: Comparison with Other Clinical Methods of Giving Oxygen[J] . W A Crosbie,J P Warren,L A Smith.Journal of International Medical Research . 1974 (3)
[10]  
Simulation of respiratory mechanics .2 Jodat R W,Horgan J D,Lange R L. Biophysical journal . 1966