Removal characteristics of microplastics by Fe-based coagulants during drinking water treatment

被引:27
|
作者
Baiwen Ma [1 ]
Wenjing Xue [1 ,2 ]
Yanyan Ding [1 ,3 ]
Chengzhi Hu [1 ,3 ]
Huijuan Liu [4 ,5 ]
Jiuhui Qu [1 ,3 ]
机构
[1] Key Laboratory of Drinking Water Science and Technology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences
[2] College of Environment and Safety Engineering,Qingdao University of Science and Technology
[3] School of Environment,State Key Joint Laboratory of Environment Simulation and Pollution Control,Tsinghua University
[4] Research Center for Water Quality and Ecology,Tsinghua University
[5] University of Chinese Academy of Sciences
基金
国家重点研发计划;
关键词
Microplastics; Removal; FeCl3·6H2O; Coagulation; Ultrafiltration;
D O I
暂无
中图分类号
TU991.2 [净水工程(给水处理)];
学科分类号
0815 ;
摘要
Microplastics have caused great concern worldwide recently due to their ubiquitous presence within the marine environment. Up to now, most attention has been paid to their sources,distributions, measurement methods, and especially their eco-toxicological effects. With microplastics being increasingly detected in freshwater, it is urgently necessary to evaluate their behaviors during coagulation and ultrafiltration(UF) processes. Herein, the removal behavior of polyethylene(PE), which is easily suspended in water and is the main component of microplastics, was investigated with commonly used Fe-based salts. Results showed that although higher removal efficiency was induced for smaller PE particles, low PE removal efficiency(below 15%) was observed using the traditional coagulation process, and was little influenced by water characteristics. In comparison to solution pH, PAM addition played a more important role in increasing the removal efficiency, especially anionic PAM at high dosage(with efficiency up to 90.9%). The main reason was ascribed to the dense floc formation and high adsorption ability because of the positively charged Fe-based flocs under neutral conditions. For ultrafiltration, although PE particles could be completely rejected,slight membrane fouling was caused owing to their large particle size. The membrane flux decreased after coagulation; however, the membrane fouling was less severe than that induced by flocs alone due to the heterogeneous nature of the cake layer caused by PE, even at high dosages of Fe-based salts. Based on the behavior exhibited during coagulation and ultrafiltration, we believe these findings will have potential application in drinking water treatment.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [1] Removal characteristics of microplastics by Fe-based coagulants during drinking water treatment
    Ma, Baiwen
    Xue, Wenjing
    Ding, Yanyan
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2019, 78 : 267 - 275
  • [2] The coagulation behavior and removal efficiency of microplastics in drinking water treatment
    Tang, Shuyuan
    Gao, Ling
    Tian, Aisi
    Zhao, Tianrui
    Zou, Donglei
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 53
  • [3] Enhancing the removal efficiency of microplastics in drinking water treatment
    Tang, Shuyuan
    Gao, Ling
    Zhao, Tianrui
    Tian, Aisi
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 57
  • [4] Characteristics of microplastic removal via coagulation and ultrafiltration during drinking water treatment
    Ma, Baiwen
    Xue, Wenjing
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    Li, Liangliang
    CHEMICAL ENGINEERING JOURNAL, 2019, 359 : 159 - 167
  • [5] Mass Concentration and Removal Characteristics of Microplastics and Nanoplastics in a Drinking Water Treatment Plant
    Xu, Yanghui
    Ou, Qin
    Wang, Xintu
    van der Hoek, Jan Peter
    Liu, Gang
    ACS ES&T WATER, 2024, 4 (08): : 3348 - 3358
  • [6] Optimization of polypropylene microplastics removal using conventional coagulants in drinking water treatment plants via response surface methodology
    Adib, Danial
    Mafigholami, Roya
    Tabeshkia, Hossein
    Walker, Tony R.
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2022, 20 (01) : 565 - 577
  • [7] Optimization of polypropylene microplastics removal using conventional coagulants in drinking water treatment plants via response surface methodology
    Danial Adib
    Roya Mafigholami
    Hossein Tabeshkia
    Tony R. Walker
    Journal of Environmental Health Science and Engineering, 2022, 20 : 565 - 577
  • [8] Occurrence and removal of microplastics in an advanced drinking water treatment plant (ADWTP)
    Wang, Zhifeng
    Lin, Tao
    Chen, Wei
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 700
  • [9] Effect of Fe and Al based coagulants and disinfectants on polyethylene microplastics removal in coagulation process through response surface methodology
    Tabatabaei, Fatemeh
    Mafigholami, Roya
    Moghimi, Hamid
    Khoramipoor, Sanaz
    WATER SCIENCE AND TECHNOLOGY, 2023, 87 (01) : 99 - 114
  • [10] Graphene Oxide/Fe-Based Composite Pre-Polymerized Coagulants: Synthesis, Characterization, and Potential Application in Water Treatment
    Tolkou, Athanasia K.
    Zouboulis, Anastasios, I
    C-JOURNAL OF CARBON RESEARCH, 2020, 6 (03):