Temperature measurement based on adaptive dual-comb absorption spectral detection

被引:0
作者
杨康文 [1 ]
李海 [1 ]
贡航 [1 ]
沈旭玲 [2 ]
郝强 [1 ]
闫明 [2 ]
黄坤 [1 ]
曾和平 [1 ,2 ]
机构
[1] Shanghai Key Laboratory of Modern Optical System, Engineering Research Center of Optical Instrument and System,Ministry of Education, School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology
[2] State Key Laboratory of Precision Spectroscopy, East China Normal University
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
ultrafast lasers; laser spectroscopy; absorption; temperature;
D O I
暂无
中图分类号
O433.1 [光谱测量];
学科分类号
0703 ; 070302 ;
摘要
We demonstrate absorption spectroscopy of water vapor for the determination of gas temperature. An adaptive dual-comb detection system is utilized to obtain precise spectroscopic data in a broadband range from 7143 to7240 cm;with a spectral resolution of 0.049 cm;. The measured spectra are in accordance with the simulated results from the HITRAN(high-resolution transmission molecular absorption) database. Several measurements are investigated in the temperature range of 500–1000 K, revealing relative deviations of less than 5% compared to the thermocouple. This broadband and accurate adaptive dual-comb spectral detection method could be a powerful tool for non-invasive combustion diagnosis.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 13 条
  • [1] Adaptive cavity-enhanced dual-comb spectroscopy[J]. WEIPENG ZHANG,XINYI CHEN,XUEJIAN WU,YAN LI,HAOYUN WEI.Photonics Research. 2019(08)
  • [2] 基于自适应双光梳系统的高分辨率快速热传感器(英文)
    Yizheng GUO
    Ming YAN
    Qiang HAO
    Kangwen YANG
    Xuling SHEN
    Heping ZENG
    [J]. Frontiers of Information Technology & Electronic Engineering, 2019, 20 (05) : 674 - 685
  • [3] 可调谐LD吸收光谱燃烧诊断技术研究进展
    杨斌
    何国强
    刘佩进
    齐宗满
    [J]. 激光技术, 2011, (04) : 503 - 510
  • [4] Speed-dependent Voigt lineshape parameter database from dual frequency comb measurements up to 1305 K. Part I: Pure H 2 O absorption, 6801–7188 cm ?1[J] . Paul J. Schroeder,Matthew J. Cich,Jinyu Yang,Fabrizio R. Giorgetta,William C. Swann,Ian Coddington,Nathan R. Newbury,Brian J. Drouin,Gregory B. Rieker.Journal of Quantitative Spectroscopy and Radiativ . 2018
  • [5] High temperature comparison of the HITRAN2012 and HITEMP2010 water vapor absorption databases to frequency comb measurements[J] . P.J. Schroeder,D.J. Pfotenhauer,J. Yang,F.R. Giorgetta,W.C. Swann,I. Coddington,N.R. Newbury,G.B. Rieker.Journal of Quantitative Spectroscopy and Radiativ . 2017
  • [6] Dual-comb spectroscopy of water vapor with a free-running semiconductor disk laser
    Link, S. M.
    Maas, D. J. H. C.
    Waldburger, D.
    Keller, U.
    [J]. SCIENCE, 2017, 356 (6343) : 1164 - 1168
  • [7] Dual frequency comb laser absorption spectroscopy in a 16 MW gas turbine exhaust
    Schroeder, P. J.
    Wright, R. J.
    Coburn, S.
    Sodergren, B.
    Cossel, K. C.
    Droste, S.
    Truong, G. W.
    Baumann, E.
    Giorgetta, F. R.
    Coddington, I.
    Newbury, N. R.
    Rieker, G. B.
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2017, 36 (03) : 4565 - 4573
  • [8] Microresonator soliton dual-comb spectroscopy
    Suh, Myoung-Gyun
    Yang, Qi-Fan
    Yang, Ki Youl
    Yi, Xu
    Vahala, Kerry J.
    [J]. SCIENCE, 2016, 354 (6312) : 600 - 603
  • [9] Reconstruction of combustion temperature and gas concentration distributions using line-of-sight tunable diode laser absorption spectroscopy
    Zhang, Zhirong
    Sun, Pengshuai
    Pang, Tao
    Xia, Hua
    Cui, Xiaojuan
    Li, Zhe
    Han, Luo
    Wu, Bian
    Wang, Yu
    Sigrist, Markus W.
    Dong, Fengzhong
    [J]. OPTICAL ENGINEERING, 2016, 55 (07)
  • [10] Algebraic tomographic reconstruction of two-dimensional gas temperature based on tunable diode laser absorption spectroscopy[J] . Junling Song,Yanji Hong,Guangyu Wang,Hu Pan.Applied Physics B . 2013 (4)