On-line Batch Process Monitoring and Diagnosing Based on Fisher Discriminant Analysis

被引:1
|
作者
赵旭
邵惠鹤
机构
[1] Shanghai 200030
[2] China
[3] Dept.of Automation Shanghai Jiaotong Univ.
关键词
batch process; on-line process monitoring; fault diagnosis; Fisher discriminant analysis (FDA); multiway principal component analysis (MPCA);
D O I
暂无
中图分类号
TP277 [监视、报警、故障诊断系统];
学科分类号
0804 ; 080401 ; 080402 ;
摘要
A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensitive to fault detection and stronger implement for monitoring. In order to improve the monitoring performance, the variables trajectories of batch process are separated into several blocks. The key to the proposed approach for on-line monitoring is to calculate the distance of block data that project to low-dimension Fisher space between new batch and reference batch. Comparing the distance with the predefine threshold, it can be considered whether the batch process is normal or abnormal. Fault diagnosis is performed based on the weights in fault direction calculated by FDA. The proposed method was applied to the simulation model of fed-batch penicillin fermentation and the results were compared with those obtained using MPCA. The simulation results clearly show that the on-line monitoring method based on FDA is more efficient than the MPCA.
引用
收藏
页码:307 / 312 +316
页数:7
相关论文
共 50 条
  • [1] Nonlinear biological batch process monitoring and fault identification based on kernel fisher discriminant analysis
    Xi, Zhang
    Weiwu, Yan
    Xu, Zhao
    Huihe, Shao
    PROCESS BIOCHEMISTRY, 2007, 42 (08) : 1200 - 1210
  • [2] On-line batch processes monitoring based on similarity of the process data
    Di, Liqing
    Xiong, Zhihua
    Yang, Xianhui
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2008, 48 (07): : 1217 - 1220
  • [3] On-line batch processes monitoring based on dissimilarity analysis
    Di, Liqing
    Xiong, Zhihua
    Yang, Xianhui
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE INFORMATION COMPUTING AND AUTOMATION, VOLS 1-3, 2008, : 519 - 522
  • [4] Localized Fisher Discriminant Analysis Based Complex Chemical Process Monitoring
    Yu, Jie
    AICHE JOURNAL, 2011, 57 (07) : 1817 - 1828
  • [5] On-line batch process monitoring using batch dynamic kernel principal component analysis
    Jia, Mingxing
    Chu, Fei
    Wang, Fuli
    Wang, Wei
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2010, 101 (02) : 110 - 122
  • [6] Adaptive consensus principal component analysis for on-line batch process monitoring
    Lee, DS
    Vanrolleghem, PA
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2004, 92 (1-3) : 119 - 135
  • [7] Adaptive Consensus Principal Component Analysis for On-Line Batch Process Monitoring
    Dae Sung Lee
    Peter A. Vanrolleghem
    Environmental Monitoring and Assessment, 2004, 92 : 119 - 135
  • [8] On-line batch process monitoring using MHMT-based MPCA
    Chen, JH
    Chen, HH
    CHEMICAL ENGINEERING SCIENCE, 2006, 61 (10) : 3223 - 3239
  • [9] On-line batch process monitoring using modified dynamic batch PCA
    Zhang, Yang
    Edgar, Thomas F.
    2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 1244 - 1249
  • [10] Batch process monitoring using on-line MIR spectroscopy
    van Sprang, ENM
    Ramaker, HJ
    Boelens, HFM
    Westerhuis, JA
    Whiteman, D
    Baines, D
    Weaver, I
    ANALYST, 2003, 128 (01) : 98 - 102