Monte Carlo simulation of single beam dose profile

被引:0
作者
LIU Xiaowei
WEN Guanghao
LI Mianfeng(Zhongshan University
机构
关键词
Monte carlo simulation; Gamma knife; Dose profile;
D O I
暂无
中图分类号
TL818 [辐射剂量计];
学科分类号
082704 ;
摘要
The single beam dose profiles of Leksell Gamma Unit are simulatedand the results are compared with the experimental results of ELEKTA. The effect ofdiameter of cylinder source on the dose profile is also studied and the yielded resultsshow that there are not much difference of the dose profiles between a point sourceand cylinder source when diameter is less than 1mm.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 50 条
  • [41] Monte Carlo simulation of single-cell irradiation by an electron microbeam
    J. H. Miller
    M. Sowa Resat
    N. F. Metting
    K. Wei
    D. J. Lynch
    W. E. Wilson
    Radiation and Environmental Biophysics, 2000, 39 : 173 - 177
  • [42] Monte Carlo simulation for magnetic behavior of single-domain particle
    Kondo, S
    Hasaka, M
    Morimura, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1996, 65 (01) : 43 - 45
  • [43] Monte Carlo simulation on heterogeneous phantom and physical dose calculation on heterogeneous organ
    Chemingui, F. Z.
    Benrachi, F.
    Bali, M. S.
    JOURNAL OF NEW TECHNOLOGY AND MATERIALS, 2019, 9 (02) : 51 - 56
  • [44] Monte Carlo simulation of a cone-beam CT system for lightweight casts
    Thuy Duong Tran
    Ngoc Ha Bui
    Kim Tuan Tran
    Ngoc Toan Tran
    Radiation Detection Technology and Methods, 2021, 5 : 504 - 512
  • [45] Introduction to Monte Carlo Simulation
    Harrison, Robert L.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2009, 1204 : 17 - 21
  • [46] Monte Carlo simulation of the dose to nuclear medicine staff wearing protective garments
    L. S. Fog
    P. Collins
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 307 - 316
  • [47] Dynamic Monte Carlo Simulation of Compositional and Topography Changes Induced by Ion Beam Irradiation
    Inai, Kensuke
    Ohya, Kaoru
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2006, 4 : 32 - 38
  • [48] Monte carlo simulation of a radiation shielding carrier for proton-beam-irradiated sample
    Ra, Se-Jin
    Jung, Myung-Hwan
    Kim, Kye-Ryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1407 - 1413
  • [49] Modeling the process of electron-beam-induced deposition by dynamic Monte Carlo simulation
    Liu, ZQ
    Mitsuishi, K
    Furuya, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (7B): : 5659 - 5663
  • [50] Estimation of Effective Dose in Monte Carlo Simulation Method for CT Coronary Angiography Patients
    Sarma, Arnabjyoti Deva
    Singha, Mrinal Kanti
    Sharma, Jibon
    Kashyap, Manash Pratim
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2023, 13 (02): : L194 - L201