Monte Carlo simulation of single beam dose profile

被引:0
|
作者
LIU Xiaowei
WEN Guanghao
LI Mianfeng(Zhongshan University
机构
关键词
Monte carlo simulation; Gamma knife; Dose profile;
D O I
暂无
中图分类号
TL818 [辐射剂量计];
学科分类号
082704 ;
摘要
The single beam dose profiles of Leksell Gamma Unit are simulatedand the results are compared with the experimental results of ELEKTA. The effect ofdiameter of cylinder source on the dose profile is also studied and the yielded resultsshow that there are not much difference of the dose profiles between a point sourceand cylinder source when diameter is less than 1mm.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 50 条
  • [1] Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
    Mohammadi, Gh R. Fallah
    Hesamnezhad, L.
    Mahdavi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 813 - 818
  • [2] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209
  • [3] The Monte Carlo simulation of the absorbed dose in quartz
    Chen, Shaowen
    Liu, Xiaowei
    Zhang, Chunxiang
    Tang, Qiang
    RADIATION MEASUREMENTS, 2009, 44 (5-6) : 626 - 628
  • [4] Monte Carlo Simulation of Single Event Effects
    Weller, Robert A.
    Mendenhall, Marcus H.
    Reed, Robert A.
    Schrimpf, Ronald D.
    Warren, Kevin M.
    Sierawski, Brian D.
    Massengill, Lloyd W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 1726 - 1746
  • [5] Beam hardening correction based on Monte Carlo simulation
    Zeng, G
    Yu, ZQ
    Yan, YL
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (02): : 178 - 182
  • [6] Monte Carlo simulation of projection electron beam lithography
    Sun, X.
    Xiao, P.
    Ding, Z. J.
    NANOSCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2007, 121-123 : 1097 - 1101
  • [7] Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy
    Fix, MK
    Keller, H
    Rüegsegger, P
    Born, EJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2739 - 2747
  • [8] Investigation of ion beam sputtering process by Monte Carlo simulation
    Mizutani, M
    Sasaki, K
    Hata, T
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART II-ELECTRONICS, 1998, 81 (12): : 41 - 47
  • [9] Monte Carlo simulation of the SRAM single event upset
    Hua, Li
    ACTA PHYSICA SINICA, 2006, 55 (07) : 3540 - 3545
  • [10] Monte Carlo simulation of PET images for injection dose optimization
    Boldys, Jiri
    Dvorak, Jiri
    Belohlavek, Otakar
    Skopalova, Magdalena
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: VIPIMAGE 2011, 2012, : 279 - 284