A high-resolution small animal SPECT system developed at Tsinghua

被引:0
作者
DAI Tiantian MATianyu~* LIU Hui CUI Junjian WEI Qingyang LIU Yaqiang WANG Shi Key Laboratory of Particle & Radiation Imaging
Department of Engineering Physics
机构
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
SPECT; Multi-pinhole collimator; High resolution; System matrix; Image reconstruction;
D O I
10.13538/j.1001-8042/nst.22.344-348
中图分类号
Q95-3 [动物学的研究与实验];
学科分类号
071002 ;
摘要
An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It was developed from a single-head clinical SPECT scanner,with a seven-pinhole collimator and a four-degree-offreedom motion control stage.Several key techniques were developed,including high-resolution image reconstruction algorithm,high accuracy geometrical calibration method,and optimized system matrix derivation scheme.The system matrix was derived from Monte-Carlo simulation and de-noised by fitting each point spread function to a two dimensional Gaussian function.Experiments of point source and ultra micro hot rod phantom were conducted.With a spatial resolution of 0.5-0.6 mm,this system provides a practical way for low-cost high-resolution animal imaging on a clinic SPECT system.
引用
收藏
页码:344 / 348
页数:5
相关论文
共 21 条
  • [1] M18-224:High accuracy geometrical calibration for half-mm animal SPECT imaging. Liu H,Ma T,Dai T,et al. IEEE NSS MIC RTSD . 2010
  • [2] Meikle S R,Kench P,Kassiou M,et al. Physics in Medicine and Biology . 2005
  • [3] Instrumentation for molecular imaging in preclinical research: micro-PET and micro-SPECT. Chatziioannou,AF. Proc Am Thorac Soc . 2005
  • [4] Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners. FP Difilippo. Physics in Medicine and Biology . 2008
  • [5] Dai Q,Qi Y. At Energ Sci Technol . 2009
  • [6] Initial studies of PET–SPECT dual-tracer imaging. Y Shao,R Yao,T Ma,P Manchiraju. IEEE Nucl Sci Symp Conf Rec . 2007
  • [7] Jan S,Santin G,Strul D,et al. Physics in Medicine and Biology . 2004
  • [8] High-resolution SPECT using multipinhole collimation. NU Schramm,G Ebel,U Engeland,T Schurrat,M Béhé,TM Behr. IEEE Transactions on Nuclear Science . 2003
  • [9] Gamma-ray imaging using a CdZnTe pixel array and a high-resolution, parallel-hole collimator. GA Kastis,HB Barber,HH Barrett,SJ Balzer,D Lu,DG Marks. IEEE Transactions on Nuclear Science . 2000
  • [10] Yao R,Ma T,Shao Y. IEEE Transactions on Nuclear Science . 2009