Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy

被引:0
|
作者
Rong-Cheng Han [1 ,2 ]
Yong-Jiang Li [3 ]
Yue-Hu Pu [3 ,4 ]
机构
[1] Shanghai Institute of Applied Physics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
关键词
Collection efficiency; Monitor ionization chamber; Pencil beam scanning; Proton therapy;
D O I
暂无
中图分类号
R730.5 [肿瘤治疗学];
学科分类号
100214 ;
摘要
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems. Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems. In this study, Boag’s theory was applied to a proton pencil beam scanning system. The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area. This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency. It was determined that collection efficiency is positively correlated with applied voltage, beam size, and beam energy,but negatively correlated with beam current intensity.Additionally, it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [41] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [42] Parametric characterization of penumbra reduction for aperture-collimated pencil beam scanning (PBS) proton therapy
    Maes, Dominic
    Regmi, Rajesh
    Taddei, Phillip
    Bloch, Charles
    Bowen, Steven
    Nevitt, Alexander
    Leuro, Erick
    Wong, Tony
    Rosenfeld, Anatoly
    Saini, Jatinder
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [43] A study of lateral fall-off (penumbra) optimisation for pencil beam scanning (PBS) proton therapy
    Winterhalter, C.
    Lomax, A.
    Oxley, D.
    Weber, D. C.
    Safai, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [44] Experimental characterisation of a proton kernel model for pencil beam scanning techniques
    De Marzi, L.
    Da Fonseca, A.
    Moignier, C.
    Patriarca, A.
    Goudjil, F.
    Mazal, A.
    Buvat, I
    Herault, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 195 - 203
  • [45] Proton FLASH: passive scattering or pencil beam scanning?
    Zhang, Guoliang
    Wang, Junliang
    Wang, Yuenan
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
  • [46] Improving the precision and performance of proton pencil beam scanning
    Safai, Sairos
    Bula, Christian
    Meer, David
    Pedroni, Eros
    TRANSLATIONAL CANCER RESEARCH, 2012, 1 (03) : 196 - 206
  • [47] Endoscopic Resection Followed by Proton Therapy With Pencil Beam Scanning for Skull Base Tumors
    Leeman, Jonathan E.
    Lee, Nancy Y.
    Zhou, Ying
    Neal, Brian
    Sine, Kevin
    Tabar, Viviane
    Cohen, Marc A.
    LARYNGOSCOPE, 2019, 129 (06) : 1313 - 1317
  • [48] Robustness evaluation of pencil beam scanning proton therapy treatment planning: A systematic review
    Sterpin, E.
    Widesott, L.
    Poels, K.
    Hoogeman, M.
    Korevaar, E. W.
    Lowe, M.
    Molinelli, S.
    Fracchiolla, F.
    RADIOTHERAPY AND ONCOLOGY, 2024, 197
  • [49] Implementation of proton therapy treatments with pencil beam scanning of targets with limited intrafraction motion
    Fracchiolla, Francesco
    Dionisi, Francesco
    Giacomelli, Irene
    Hild, Sebastian
    Esposito, Pier Giorgio
    Lorentini, Stefano
    Engwall, Erik
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 215 - 220
  • [50] Effects of spot size errors in DynamicARC pencil beam scanning proton therapy planning
    Rana, Suresh
    Rosenfeld, Anatoly B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (23)