Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy

被引:0
|
作者
Rong-Cheng Han [1 ,2 ]
Yong-Jiang Li [3 ]
Yue-Hu Pu [3 ,4 ]
机构
[1] Shanghai Institute of Applied Physics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
关键词
Collection efficiency; Monitor ionization chamber; Pencil beam scanning; Proton therapy;
D O I
暂无
中图分类号
R730.5 [肿瘤治疗学];
学科分类号
100214 ;
摘要
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems. Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems. In this study, Boag’s theory was applied to a proton pencil beam scanning system. The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area. This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency. It was determined that collection efficiency is positively correlated with applied voltage, beam size, and beam energy,but negatively correlated with beam current intensity.Additionally, it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [31] Robust treatment planning in whole pelvis pencil beam scanning proton therapy for prostate cancer
    Butala, Anish A.
    Ingram, W. Scott
    O'Reilly, Shannon E.
    Hartl, Brett
    Kassaee, Ali
    Deville, Curtiland
    Vapiwala, Neha
    MEDICAL DOSIMETRY, 2020, 45 (04) : 334 - 338
  • [32] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05)
  • [33] MRI Guided Proton Therapy: pencil beam scanning in an MRI fringe field
    Oborn, B. M.
    Dowdell, S.
    Metcalfe, P. E.
    Crozier, S.
    Guatelli, S.
    Rosenfeld, A. B.
    Mohan, R.
    Keall, P. J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S78 - S79
  • [34] Consistency in quality correction factors for ionization chamber dosimetry in scanned proton beam therapy
    Sorriaux, Jefferson
    Testa, Mauro
    Paganetti, Harald
    Bertrand, Damien
    Lee, John Aldo
    Palmans, Hugo
    Vynckier, Stefaan
    Sterpin, Edmond
    MEDICAL PHYSICS, 2017, 44 (09) : 4919 - 4927
  • [35] Simulation and experimental benchmarking of a proton pencil beam scanning nozzle model for development of MR-integrated proton therapy
    Oborn, Bradley M.
    Semioshkina, Ekaterina
    van der Kraaij, Erik
    Hoffmann, Aswin L.
    MEDICAL PHYSICS, 2024, 51 (09) : 6196 - 6205
  • [36] Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanning
    Zeng, C.
    Plastaras, J. P.
    Tochner, Z. A.
    White, B. M.
    Hill-Kayser, C. E.
    Hahn, S. M.
    Both, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07) : 3013 - 3029
  • [37] Assessment of pencil beam scanning proton therapy beam delivery accuracy through machine learning and log file analysis
    Ranjith, C. P.
    Krishnan, Mayakannan
    Raveendran, Vysakh
    Chaudhari, Lalit
    Laskar, Siddhartha
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 127
  • [38] Commissioning dose computation model for proton source in pencil beam scanning therapy by convolution neural networks
    Liu, Yaoying
    Shang, Xuying
    Zhao, Wei
    Li, Nan
    Qu, Baolin
    Zou, Yue
    Le, Xiaoyun
    Zhang, Gaolong
    Xu, Shouping
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15)
  • [39] Secondary neutron dose contribution from pencil beam scanning, scattered and spatially fractionated proton therapy
    Leite, A. M. M.
    Ronga, M. G.
    Giorgi, M.
    Ristic, Y.
    Perrot, Y.
    Trompier, F.
    Prezado, Y.
    Crehange, G.
    De Marzi, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22)
  • [40] Pencil Beam Scanning Proton Therapy for Paediatric Neuroblastoma with Motion Mitigation Strategy for Moving Target Volumes
    Lim, P. S.
    Pica, A.
    Hrbacek, J.
    Bachtiary, B.
    Walser, M.
    Lomax, A. J.
    Weber, D. C.
    CLINICAL ONCOLOGY, 2020, 32 (07) : 467 - 476