Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system

被引:0
|
作者
Li-Juan Wang1
2 Institute of Analytical Sciences
机构
关键词
chemiluminescence; KMnO4; loxoprofen; naproxen;
D O I
暂无
中图分类号
R927.2 [药物含量测定];
学科分类号
摘要
A novel flow injection chemiluminescence(CL)method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4 and Na2SO3 in acid media.The CL intensity of KMnO4-Na2SO3 was greatly enhanced in the presence of loxoprofen and naproxen.The mechanism of the CL reaction was studied by the kinetic process and UV-vis absorption and the conditions were optimized.Under optimized conditions,the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0×10-8-1.0×10-5g/mL and 2.0×10-7-4.0×10-6g/mL with the detection limit of 2.0×10-8g/mL and 3.0×10-8g/mL(S/N=3),respectively.The relative standard deviations were 2.39% and 1.37% for 5.0×10-7g/mL naproxen and 5.0×10-7g/mL loxoprofen(n=10),respectively.The proposed method was satisfactorily applied to the determination of loxoprofen and naproxen in pharmaceutical preparations.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [1] Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
    Wang, Li-Juan
    Thng, Yu-Hai
    Liu, Yang-Hao
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2011, 1 (01) : 51 - 56
  • [2] Rapid Flow-Injection Method for the Determination of Colistin by Sensitized Chemiluminescence Using the Acidic Permanganate-Sulfite System
    Bello Lopez, Miguel Angel
    Callejon Mochon, Manuel
    Fernandez-Torres, Rut
    Villar Navarro, Mercedes
    Ocana Gonzalez, Juan Antonio
    ANALYTICAL LETTERS, 2009, 42 (10) : 1471 - 1478
  • [3] Flow injection determination of papaverine based on its sensitizing effect on the chemiluminescence reaction of permanganate-sulfite
    Ya-Feng Zhuang
    Si-Chun Zhang
    Jun-Sheng Yu
    Huang-Xian Ju
    Analytical and Bioanalytical Chemistry, 2003, 375 : 281 - 286
  • [4] Flow injection determination of papaverine based on its sensitizing effect on the chemiluminescence reaction of permanganate-sulfite
    Zhuang, YF
    Zhang, SC
    Yu, JS
    Ju, HX
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) : 281 - 286
  • [5] Chemiluminescence determination of atenolol in biological fluids by a europium-sensitized permanganate-sulfite system
    Dongdong Li
    Jianxiu Du
    Jiuru Lu
    Microchimica Acta, 2008, 161 : 169 - 173
  • [6] Chemiluminescence determination of atenolol in biological fluids by a europium-sensitized permanganate-sulfite system
    Li, Dongdong
    Du, Jianxiu
    Lu, Jiuru
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 169 - 173
  • [7] Determination of iodide using flow injection with acidic potassium permanganate chemiluminescence detection
    Yaqoob, Mohammad
    Atiq-ur-Rehman
    Waseem, Amir
    Nabi, Abdul
    LUMINESCENCE, 2006, 21 (04) : 221 - 225
  • [8] Determination of thiourea by terbium (III)/prulifloxacin sensitized potassium permanganate-sulfite chemiluminescence with quenching method
    Hu, Qi
    Chen, Si
    Chen, Fang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 264
  • [9] Flow-Injection Determination of Retinol and Tocopherol in Pharmaceuticals with Acidic Potassium Permanganate Chemiluminescence
    Waseem, Amir
    Rishi, Lubna
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2009, 25 (03) : 407 - 412
  • [10] Flow-injection Determination of Vanadium in seawater samples with acidic Potassium Permanganate Chemiluminescence
    Department of Chemistry, University of Balochistan, Quetta, Pakistan
    Anal. Sci., 3 (355-360):