Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope

被引:1
|
作者
Siok Siong Ching [1 ]
Yih Kai Tan [1 ]
机构
[1] Department of Surgery, Changi General Hospital, Singapore 529889, Singapore
关键词
Bowel sounds; Intestinal obstruction; Spectral analysis; Electronic stethoscope;
D O I
暂无
中图分类号
R574 [肠疾病];
学科分类号
1002 ; 100201 ;
摘要
AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3MTH Littmann Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, soundto-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patientshad acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen between acute large bowel obstruction and large bowel pseudoobstruction. For patients with small bowel obstruction, the sound-to-sound interval was significantly longer in those who subsequently underwent surgery compared with those treated non-operatively (median 1.29 s vs 0.63 s, P < 0.001). There was no correlation between bowel calibre and bowel sound characteristics in both acute small bowel obstruction and acute large bowel obstruction. CONCLUSION: Auscultation of bowel sounds is nonspecific for diagnosing bowel obstruction. Differences in sound characteristics between large bowel and small bowel obstruction may help determine the likely site of obstruction.
引用
收藏
页码:4585 / 4592
页数:8
相关论文
共 50 条
  • [1] Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope
    Ching, Siok Siong
    Tan, Yih Kai
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (33) : 4585 - 4592
  • [2] CLINICAL-APPLICATION OF SPECTRAL-ANALYSIS OF BOWEL SOUNDS IN INTESTINAL-OBSTRUCTION
    YOSHINO, H
    ABE, Y
    YOSHINO, T
    OHSATO, K
    DISEASES OF THE COLON & RECTUM, 1990, 33 (09) : 753 - 757
  • [3] Opinions on Computer Audition for Bowel Sounds Analysis in Intestinal Obstruction: Opportunities and Challenges From a Clinical Point of View
    Yang, Zhu
    Huang, Luming
    Jiang, Jingsun
    Hu, Bing
    Tang, Chengwei
    Li, Jing
    FRONTIERS IN MEDICINE, 2021, 8
  • [4] Study of Electronic Stethoscope as Prospective Analysis Tool for Cardiac Sounds
    Khan, Sibghatullah I.
    Ahmed, Vasif
    SMART TRENDS IN INFORMATION TECHNOLOGY AND COMPUTER COMMUNICATIONS, SMARTCOM 2016, 2016, 628 : 706 - 713
  • [5] REGISTRATION OF INTESTINAL MOTILITY BY THE ANALYSIS OF BOWEL SOUNDS
    BLUMEL, G
    BIRK, M
    HEINKELMANN, W
    SOMMOGGY, SV
    THEISINGER, W
    WIESMEIER, R
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1979, 349 : 619 - 619
  • [6] A dataset of lung sounds recorded from the chest wall using an electronic stethoscope
    Fraiwan, Mohammad
    Fraiwan, Luay
    Khassawneh, Basheer
    Ibnian, Ali
    DATA IN BRIEF, 2021, 35
  • [7] Development of an Electronic Stethoscope and a Classification Algorithm for Cardiopulmonary Sounds
    Wu, Yu-Chi
    Han, Chin-Chuan
    Chang, Chao-Shu
    Chang, Fu-Lin
    Chen, Shi-Feng
    Shieh, Tsu-Yi
    Chen, Hsian-Min
    Lin, Jin-Yuan
    SENSORS, 2022, 22 (11)
  • [8] ARMA-based spectral bandwidth for evaluation of bowel motility by the analysis of bowel sounds
    Emoto, Takahiro
    Shono, Koichi
    Abeyratne, Udantha R.
    Okahisa, Toshiya
    Yano, Hiromi
    Akutagawa, Masatake
    Konaka, Shinsuke
    Kinouchi, Yohsuke
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (08) : 925 - 936
  • [9] ACQUISITION AND CHARACTERIZATION OF BOWEL SOUNDS USING LabVIEW SOFTWARE
    Chanu, Oinam Robita
    Raj, V. Karthik
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2018, 30 (02):
  • [10] Intestinal chondrolipoma: uncommon cause of bowel obstruction
    Jung, Hye-Ra
    Park, Woo-Hyun
    Choi, Soon-Ok
    Kwon, Kun-Young
    Lee, Sang-Sook
    JOURNAL OF PEDIATRIC SURGERY, 2007, 42 (10) : U19 - U21