Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer

被引:0
作者
BAI Tao
LU Yu
YAN Gang
YU Jianlin
机构
[1] DepartmentofRefrigerationandCryogenicEngineering,SchoolofEnergyandPowerEngineering,Xi'anJiaotongUniversity
关键词
D O I
暂无
中图分类号
TB65 [制冷机械和设备];
学科分类号
0807 ; 080705 ;
摘要
In this paper, an ejector enhanced two-stage auto-cascade refrigeration cycle(EARC) using ternary mixture R600 a/R32/R1150 is proposed for application of-80°C freezing. In EARC cycle, an ejector was employed to recover the expansion work in the throttling processes and lifted the suction pressure of the compressor. The performances of the ejector enhanced two-stage auto-cascade refrigeration cycle and conventional auto-cascade refrigeration cycle(CARC) were compared using thermodynamic analysis methods. The influences of the important operation parameters including mass fraction ratio of the mixture, fluid quality at the second separator inlet, condensation temperature, evaporation temperature, and expansion ratio of expansion valve on the performances of EARC cycle were discussed in detail. The results indicate that ternary mixture R600 a/R32/R1150 has the optimal mass fraction ratio of 0.45/0.2/0.35 with respect to the maximum COP. The EARC cycle yields higher performance than the CARC cycle in terms of COP, exergy efficiency and volumetric refrigeration capacity. And 4.9%–36.5% improvement in COP and 6.9%–34.3% higher exergy efficiency could be obtained in EARC cycle comparing with CARC cycle. The finding of this study suggests that the EARC cycle has a promising application potential for low temperature freezing.
引用
收藏
页码:2015 / 2026
页数:12
相关论文
共 24 条
[1]  
带气液分离器自动复叠系统中节流阀开度引起的混合工质浓度偏移(英文)[J]. 许雄文,刘金平,曹乐.Chinese Journal of Chemical Engineering. 2015(01)
[2]  
Performance of a new two-stage transcritical CO2 refrigeration cycle with two ejectors[J] . F. Eskandari Manjili,M. Cheraghi.Applied Thermal Engineering . 2019
[3]  
Performance improvement of ejector expansion refrigeration cycles employing a booster compressor using different refrigerants: Thermodynamic analysis and optimization[J] . H. Rostamnejad,V. Zare.International Journal of Refrigeration . 2019
[4]  
Experimental investigation on the concentration distribution behaviors of mixture in an ejector enhanced auto-cascade refrigeration system[J] . Tao Bai,Gang Yan,Jianlin Yu.International Journal of Refrigeration . 2019
[5]  
Investigation of the ejector application in the cryogenic Joule-Thomson refrigeration system[J] . Jisung Lee,Seungwhan Baek,Sangkwon Jeong.Energy . 2018
[6]  
Experimental research on the pull-down performance of an ejector enhanced auto-cascade refrigeration system for low-temperature freezer[J] . Tao Bai,Gang Yan,Jianlin Yu.Energy . 2018
[7]  
Experimental investigation of an ejector-enhanced auto-cascade refrigeration system[J] . Tao Bai,Gang Yan,Jianlin Yu.Applied Thermal Engineering . 2018
[8]  
Effects of ejector geometries on performance of ejector-expansion R410A air conditioner considering cooling seasonal performance factor[J] . Yongseok Jeon,Jongho Jung,Dongwoo Kim,Sunjae Kim,Yongchan Kim.Applied Energy . 2017
[9]  
Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode[J] . Bura Sreenivas,H. Gurudath Nayak,G. Venkatarathnam.Cryogenics . 2017
[10]   Experimental investigation of the performance of a single-stage auto-cascade refrigerator [J].
Rui, Shengjun ;
Zhang, Hua ;
Zhang, Bohan ;
Wen, Dongsheng .
HEAT AND MASS TRANSFER, 2016, 52 (01) :11-20