摘要
Biosensors are widely used in immunoassay. The biosensor chip carries a receptor which is used in immunoassay and the chip properties have an important influence on the detecting sensitivity of the biosensor. This paper describes a polystyrene\|based biosensor chip developed and used as part of a surface plasmon resonance (SPR) biosensor. The SPR biosensor has a much higher detecting sensitivity than enzyme\|linked immunoserbent assay (ELISA).
引用
收藏
页码:1495 / 1498
页数:4
相关论文
共 50 条
  • [21] Comparative analysis for reflectivity of graphene based SPR biosensor
    Goutam Mohanty
    Bijay Kumar Sahoo
    Jamil Akhtar
    Optical and Quantum Electronics, 2015, 47 : 1911 - 1918
  • [22] SPR sensor chip based on polymer waveguide
    Tobita, T
    Tabei, H
    Imamura, A
    Iwasaki, Y
    Niwa, O
    DESIGN AND FABRICATION OF PLANAR OPTICAL WAVEGUIDE DEVICES AND MATERIALS, 2002, 4805 : 114 - 124
  • [23] SPR Based Biosensor for the Detection of Abnormal Growth of Tissues
    Chaitra, S.
    Veena, C.
    Rao, K. Srinivas
    Sharan, Preeta
    2017 INTERNATIONAL CONFERENCE ON NEXTGEN ELECTRONIC TECHNOLOGIES: SILICON TO SOFTWARE (ICNETS2), 2017, : 149 - 153
  • [24] SPR-based single nucleotide mismatch biosensor
    Milkani, Eftim
    Khaing, Aung M.
    Morais, Sergi
    Lambert, Christopher R.
    McGimpsey, W. Grant
    ANALYTICAL METHODS, 2011, 3 (01) : 122 - 132
  • [25] Comparative analysis for reflectivity of graphene based SPR biosensor
    Mohanty, Goutam
    Sahoo, Bijay Kumar
    Akhtar, Jamil
    OPTICAL AND QUANTUM ELECTRONICS, 2015, 47 (07) : 1911 - 1918
  • [26] Detection of the mycovirus OMSV in the edible mushroom, Pleurotus ostreatus, using an SPR biosensor chip
    Kim, Sang-Woo
    Kim, Min-Gon
    Kim, Jinju
    Lee, Hyun-Sook
    Ro, Hyeon-Su
    JOURNAL OF VIROLOGICAL METHODS, 2008, 148 (1-2) : 120 - 124
  • [27] A highly sensitive SPR biosensor based on a graphene oxide sheet modified with gold bipyramids, and its application to an immunoassay for rabbit IgG
    Qiong Wu
    Daqian Song
    Di Zhang
    Hua Zhang
    Yaying Ding
    Yong Yu
    Ying Sun
    Microchimica Acta, 2015, 182 : 1739 - 1746
  • [28] A highly sensitive SPR biosensor based on a graphene oxide sheet modified with gold bipyramids, and its application to an immunoassay for rabbit IgG
    Wu, Qiong
    Song, Daqian
    Zhang, Di
    Zhang, Hua
    Ding, Yaying
    Yu, Yong
    Sun, Ying
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1739 - 1746
  • [29] An Immunoassay Chip Based on Electrowetting on Dielectrics
    Zhu Liang
    Ye Xiong-Ying
    Feng Yan-Ying
    Feng Jin-Yang
    Wu Yan-Bin
    Zhou Zhao-Ying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 471 - 476
  • [30] USE OF MODIFIED POLYSTYRENE MICROWELLS TO ENHANCE IMMUNOASSAY SENSITIVITY
    MCLEAN, L
    AMERICAN BIOTECHNOLOGY LABORATORY, 1992, 10 (05): : 58 - 58