Thermal and thermo-hydraulic performance investigation of double-pass packed bed solar air heaters under external recycle

被引:0
作者
Dhiman P. [1 ]
Singh S. [1 ]
机构
[1] Mechanical Engineering Department, National Institute of Technology, Hamirpur, HP
关键词
heater; packed bed; porosity; recycle; thermal efficiency;
D O I
10.1080/14786451.2015.1017496
中图分类号
学科分类号
摘要
In the present investigation, two types (Type A and Type B) of the double-pass packed bed solar air heater under external recycle are investigated theoretically. In Type A, the porous media is considered in the upper channel, whereas in Type B, the porous media is considered in the lower channel. Iron scraps are used as a packed bed material (porous media) to strengthen the convective heat transfer coefficient for air flowing through the packed bed. The mathematical model for these two air heaters operating under forced convection mode is presented. The results revealed that the thermal and thermo-hydraulic efficiencies of Type A are higher as compared to Type B. In order to validate the models, the theoretical results obtained from the conventional model of Type B are compared with the theoretical results obtained from the previous investigation and showed that good agreement is achieved. © 2015 Taylor & Francis.
引用
收藏
页码:242 / 258
页数:16
相关论文
共 19 条
[1]  
Boyce W.E., Diprima R.C., Elementary Differential Equations and Boundary Value Problems, (1969)
[2]  
Dhiman P., Thakur N.S., Chauhan S.R., Thermal and Thermo-hydraulic Performance of Counter and Parallel Flow Packed Bed Solar Air Heaters, Renewable Energy, 46, 1, pp. 259-268, (2012)
[3]  
Dhiman P., Thakur N.S., Kumar A., Singh S., An Analytical Model to Predict the Thermal Performance of a Novel Parallel Flow Packed Bed Solar Air Heater, Applied Energy, 88, 6, pp. 2157-2167, (2011)
[4]  
Garg H.P., Advances in Solar Energy Technology, (1987)
[5]  
Ho C.D., Chang H., Chi W.R., Sheng L.C., Performance Improvement of a Double-Pass Solar Air Heater with Fins and Baffles under Recycling Operation, Applied Energy, 100, pp. 155-163, (2012)
[6]  
Ho C.D., Lin C.S., Chuang Y.C., Chao C.C., Performance of Wire Mesh Packed Double-Pass Solar Air Heaters with External Recycle, Renewable Energy, 57, pp. 479-489, (2013)
[7]  
Ho C.D., Yeh H.M., Cheng T.W., Chen T.C., Wang R.C., The Influences of Recycle on Performance of Baffled Double-Pass Flat-Plate Solar Air Heaters with Internal Fins Attached, Applied Energy, 86, pp. 1470-1478, (2009)
[8]  
Ho C.D., Yeh C.W., Hsieh S.M., Improvement in Device Performance of Multi-pass Flat-Plate Solar Air Heaters with External Recycle, Renewable Energy, 30, pp. 1601-1621, (2005)
[9]  
Ho C.D., Yeh H.M., Tsung C.C., Collector Efficiency of Upward-Type Double Pass Solar Air Heaters with Fins Attached, International Communications in Heat and Mass Transfer, 38, pp. 49-56, (2011)
[10]  
Ho C.D., Yeh H.M., Wang R.C., Heat-Transfer Enhancement in Double-Pass Flat-Plate Solar Air Heaters with Recycle, Energy, 30, pp. 2796-2817, (2005)