Diagnostic accuracy of digital breast tomosynthesis and digital mammography in women with dense or non-dense breast tissue: A systematic review and meta-analysis

被引:0
作者
Lin, Hao [1 ]
Zhang, Yimeng [2 ]
Wu, Lixia [3 ]
Li, Ceng [4 ]
机构
[1] Yangtze River Shipping Wuhan Brain Hosp, Gen Hosp, Dept Radiol, Wuhan, Peoples R China
[2] Zhejiang Chinese Med Univ, Dept Gen Surg, Affiliated Hosp 3, Hangzhou, Peoples R China
[3] Zhejiang Chinese Med Univ, Dept Pulm & Crit Care Med, Affiliated Hosp 3, Hangzhou, Peoples R China
[4] Xuzhou Canc Hosp, Dept Radiol, Xuzhou, Jiangsu, Peoples R China
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2025年 / 34卷 / 03期
关键词
breast cancer; digital mammography; digital breast tomosynthesis; cancer detection rate; overall recall rate; FUNNEL PLOTS; CANCER; RISK;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Despite its excellent screening effectiveness and sensitivity for breast cancer (BC), digital breast tomosynthesis (DBT) is controversial due to its high radiation exposure and long reading time. This study examines the diagnostic accuracy of DBT and digital mammography (DM) for BC screening and diagnosis in women with dense or non-dense breast tissue. Materials and methods. PRISMA-compliant searches were performed on Medline, Embase, PubMed, Web of Science, and the Cochrane databases forarticles comparing DBT and DM for BC screening until March 2023. Meta-analysis was performed using RevMan sofware, and the Cochrane Risk of Bias Assessment Tool was employed to assess study quality. Results. This meta-analysis included 11 trials with a total of 2,124,018 individuals. Screening with DBT resulted in a greater cancer detection rate, as demonstrated by a risk ratio (RR) of 1.27 (95% confidence interval (95% CI): 1.14-1.41). Digital breast tomosynthesis also had a reduced recall rate, with a RR of 0.88 (95% CI: 0.78-0.99), highersensitivity and specificity values (pooled sensitivity of 0.91 (95% CI: 0.59-0.99)) and pooled specificity of 0.90 (95% CI: 0.42-1.0)) than DM (pooled sensitivity of 0.86 (95% CI: 0.52-1.0) and pooled specificity of 0.81 (95% CI: 0.12-1.0)). All acquired data exhibited reliability, lack of bias and statistical significance (p < 0.05). Conclusions. Digital breast tomosynthesis is a more effective screening and diagnostic assessment tool for women with dense or non-dense breasts than DM in terms of incremental cancer detection, sensitivity and recall rate.
引用
收藏
页码:315 / 326
页数:12
相关论文
共 52 条
[1]   A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial [J].
Aase, Hildegunn S. ;
Holen, Asne S. ;
Pedersen, Kristin ;
Houssami, Nehmat ;
Haldorsen, Ingfrid S. ;
Sebuodegard, Sofie ;
Hanestad, Berit ;
Hofvind, Solveig .
EUROPEAN RADIOLOGY, 2019, 29 (03) :1175-1186
[2]   Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis [J].
Alabousi, Mostafa ;
Wadera, Akshay ;
Al-Ghita, Mohammed Kashif ;
Al-Ghetaa, Rayeh Kashef ;
Salameh, Jean-Paul ;
Pozdnyakov, Alex ;
Zha, Nanxi ;
Samoilov, Lucy ;
Sharifabadi, Anahita Dehmoobad ;
Sadeghirad, Behnam ;
Freitas, Vivianne ;
McInnes, Matthew D. F. ;
Alabousi, Abdullah .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06) :680-690
[3]   Breast Cancer Screening with Digital Breast Tomosynthesis: Are Initial Benefits Sustained? [J].
Bahl, Manisha ;
Mercaldo, Sarah ;
Dang, Pragya A. ;
Mccarthy, Anne Marie ;
Lowry, Kathryn P. ;
Lehman, Constance D. .
RADIOLOGY, 2020, 295 (03) :529-539
[4]   OPERATING CHARACTERISTICS OF A BANK CORRELATION TEST FOR PUBLICATION BIAS [J].
BEGG, CB ;
MAZUMDAR, M .
BIOMETRICS, 1994, 50 (04) :1088-1101
[5]   Digital breast tomosynthesis (DBT): recommendations from the Italian College of Breast Radiologists (ICBR) by the Italian Society of Medical Radiology (SIRM) and the Italian Group for Mammography Screening (GISMa) [J].
Bernardi, Daniela ;
Belli, Paolo ;
Benelli, Eva ;
Brancato, Beniamino ;
Bucchi, Lauro ;
Calabrese, Massimo ;
Carbonaro, Luca A. ;
Caumo, Francesca ;
Cavallo-Marincola, Beatrice ;
Clauser, Paola ;
Fedato, Chiara ;
Frigerio, Alfonso ;
Galli, Vania ;
Giordano, Livia ;
Rossi, Paolo Giorgi ;
Golinelli, Paola ;
Morrone, Doralba ;
Mariscotti, Giovanna ;
Martincich, Laura ;
Montemezzi, Stefania ;
Naldoni, Carlo ;
Paduos, Adriana ;
Panizza, Pietro ;
Pediconi, Federica ;
Querci, Fiammetta ;
Rizzo, Antonio ;
Saguatti, Gianni ;
Tagliafico, Alberto ;
Trimboli, Rubina M. ;
Zappa, Marco ;
Zuiani, Chiara ;
Sardanelli, Francesco .
RADIOLOGIA MEDICA, 2017, 122 (10) :723-730
[6]   Mammographic density and the risk and detection of breast cancer [J].
Boyd, Norman F. ;
Guo, Helen ;
Martin, Lisa J. ;
Sun, Limei ;
Stone, Jennifer ;
Fishell, Eve ;
Jong, Roberta A. ;
Hislop, Greg ;
Chiarelli, Anna ;
Minkin, Salomon ;
Yaffe, Martin J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (03) :227-236
[7]   Assessment of disease extent on contrast-enhanced MRI in breast cancer detected at digital breast tomosynthesis versus digital mammography alone [J].
Chudgar, A. V. ;
Conant, E. F. ;
Weinstein, P. ;
Keller, M. ;
Synnestvedt, M. ;
Yamartino, P. ;
McDonald, E. S. .
CLINICAL RADIOLOGY, 2017, 72 (07) :573-579
[8]   Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium [J].
Conant, Emily F. ;
Beaber, Elisabeth F. ;
Sprague, Brian L. ;
Herschorn, Sally D. ;
Weaver, Donald L. ;
Onega, Tracy ;
Tosteson, Anna N. A. ;
McCarthy, Anne Marie ;
Poplack, Steven P. ;
Haas, Jennifer S. ;
Armstrong, Katrina ;
Schnall, Mitchell D. ;
Barlow, William E. .
BREAST CANCER RESEARCH AND TREATMENT, 2016, 156 (01) :109-116
[9]   Improving Youden plots by including analytical performance specifications [J].
Coucke, Wim ;
Soumali, Mohamed Rida ;
Badrick, Tony .
CLINICA CHIMICA ACTA, 2022, 531 :212-216
[10]   Screening for Dense Breasts: Digital Breast Tomosynthesis [J].
Destounis, Stamatia V. ;
Morgan, Renee ;
Arieno, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) :261-264