Influence of Healing Abutment Height on Secondary Implant Stability Using Resonance Frequency Analysis: A Prospective Clinical Study

被引:0
作者
Martin-Martin, Alicia [1 ,2 ]
Perez-Pevida, Esteban [1 ,2 ,3 ]
Fernandez-Hernandez, Saray [2 ,3 ]
Lubillo-Valdeon, Jaime [2 ]
Brizuela-Velasco, Aritza [3 ]
机构
[1] Univ Salamanca, Fac Med, Dept Surg, C Alfonso X El Sabio S-N, Salamanca 37007, Spain
[2] Miguel Cervantes European Univ, Fac Oral Sci, C del Padre Julio Chevalier 2, Valladolid 47012, Spain
[3] Miguel Cervantes European Univ, Fac Hlth Sci, DENS iA Res Grp, C del Padre Julio Chevalier 2, Valladolid 47012, Spain
关键词
implant stability; resonance frequency analysis; healing abutments; one surgical phase; insertion torque; marginal bone level; DENTAL IMPLANTS; RADIOGRAPHIC EVALUATION; TITANIUM IMPLANTS; BONE; IMMEDIATE; PLACEMENT; CRESTAL;
D O I
10.3390/jcm14145140
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: The aim of the present study is to evaluate the influence of the healing abutment height on secondary implant stability measured by resonance frequency analysis. In this prospective observational clinical study of 30 implants, the secondary stability of the implant was measured via resonance frequency analysis of the abutment during the osseointegration process. Methods: Two groups were compared: a <4 group (n = 15), with a space between the healing abutment and the antagonist of <4 mm, and a >= 4 group (n = 15), with a space of >= 4 mm. Results: Statistically significant differences (p < 0.05) in the implant stability values obtained at surgery (T0) and at the eighth week of osseointegration (T8) were observed between the two groups, with higher values for the <4 group. Pearson's correlation analysis revealed a trend towards a significant relationship with the mean force (-0.6546) and a linear inverse relationship, so that by decreasing the distance between the abutment and the contact with the antagonist, the secondary implant stability values increased. A comparison of the mesial and distal peri-implant marginal bone levels at T0 and T8 did not reveal statistically significant differences (p > 0.05). A greater healing abutment height, placing it closer to the antagonist, increases and accelerates secondary stability, as measured by resonance frequency analysis. Conclusions: The results of the study support the recommendation of using high healing abutments, placing the abutment close to the opposing occlusal plane, according to biomechanical criteria.
引用
收藏
页数:16
相关论文
共 37 条
[1]   Effects of different loading protocols on the secondary stability and peri-implant bone density of the single implants in the posterior maxilla [J].
Akoglan, Mucahide ;
Tatli, Ufuk ;
Kurtoglu, Cem ;
Salimov, Fariz ;
Kurkcu, Mehmet .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) :624-631
[2]   A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial [J].
Albertini, Matteo ;
Herrero-Climent, Federico ;
Maria Diaz-Castro, Carmen ;
Nart, Jose ;
Fernandez-Palacin, Ana ;
Vicente Rios-Santos, Jose ;
Herrero-Climent, Mariano .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) :1-19
[3]  
Albrektsson T, 1993, Int J Prosthodont, V6, P95
[4]   Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations [J].
Alexandre Gehrke, Sergio ;
Aramburu, Jaime Junior ;
Perez-Diaz, Leticia ;
do Prado, Tales Dias ;
Dedavid, Berenice Anina ;
Mazon, Patricia ;
De Aza, Piedad N. .
PLOS ONE, 2020, 15 (05)
[5]  
Balleri Piero, 2002, Clin Implant Dent Relat Res, V4, P128, DOI 10.1111/j.1708-8208.2002.tb00162.x
[6]   Influence of the Elastic Modulus on the Osseointegration of Dental Implants [J].
Brizuela, Aritza ;
Herrero-Climent, Mariano ;
Rios-Carrasco, Elisa ;
Vicente Rios-Santos, Jose ;
Perez, Roman A. ;
Maria Manero, Jose ;
Gil Mur, Javier .
MATERIALS, 2019, 12 (06)
[7]   The functional loading of implants increases their stability: A retrospective clinical study [J].
Brizuela-Velasco, Aritza ;
Chavarri-Prado, David .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (01) :122-129
[8]   Relationship Between Insertion Torque and Resonance Frequency Measurements, Performed by Resonance Frequency Analysis, in Micromobility of Dental Implants: An In Vitro Study [J].
Brizuela-Velasco, Aritza ;
Alvarez-Arenal, Angel ;
Javier Gil-Mur, Francisco ;
Herrero-Climent, Mariano ;
Chavarri-Prado, David ;
Chento-Valiente, Yelko ;
Dieguez-Pereira, Markel .
IMPLANT DENTISTRY, 2015, 24 (05) :607-611
[9]   The Bone Buttress Theory: The Effect of the Mechanical Loading of Bone on the Osseointegration of Dental Implants [J].
Chavarri-Prado, David ;
Brizuela-Velasco, Aritza ;
Alvarez-Arenal, Angel ;
Dieguez-Pereira, Markel ;
Perez-Pevida, Esteban ;
Viteri-Agustin, Iratxe ;
Estrada-Martinez, Alejandro .
BIOLOGY-BASEL, 2021, 10 (01) :1-15
[10]   Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs [J].
Corso, M ;
Sirota, C ;
Fiorellini, J ;
Rasool, F ;
Szmukler-Moncler, S ;
Weber, HP .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (04) :428-435