Evaluation of the Splitting Tensile Strength of Ultra-High Performance Concrete

被引:3
作者
An Hoang Le [1 ]
机构
[1] Nguyen Tat Thanh Univ, NTT Hitech Inst, Ho Chi Minh City, Vietnam
来源
FIBRE REINFORCED CONCRETE: IMPROVEMENTS AND INNOVATIONS, BEFIB 2020 | 2021年 / 30卷
关键词
Ultra-high performance concrete; Splitting tensile strength; Fibers; Compressive strength; Splitting tests; MECHANICAL-PROPERTIES; STEEL FIBERS;
D O I
10.1007/978-3-030-58482-5_101
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The splitting tensile strength of ultra-high performance concrete (UHPC) is much larger than that of normal concrete. It was found that the studies on UHPC has mainly focused on the direct tensile strength or flexural strength, while there has been insufficient work to evaluate the splitting strength characteristics of UHPC. Therefore, this study is aimed at presenting experimental and statistical evaluation of the splitting tensile strength of UHPC. The splitting tests were conducted on cylindrical specimens of 100 x 200 mm size. UHPC was designed to achieve a nominal compressive strength of 200 MPa at the age of 28 days. Macro steel fibers were used to reinforce the UHPC by volumetric percentages of 0, 1, and 2%. The effect of fiber volume on the splitting tensile strength was investigated by the test results. The values of the splitting tensile strength of UHPC with and without fibers in some previous studies were collected together with this study and subsequently verified with the predictions of the splitting tensile strength obtained from the existing models. The appropriateness of these existing models was clarified. Finally, based on the regression analysis on the collected test results, a simplified equation was proposed to estimate the splitting tensile strength of UHPC having compressive strength varying between 120 and 200 MPa.
引用
收藏
页码:1149 / 1160
页数:12
相关论文
共 31 条
[1]  
An L., 2017, Constr. Build. Mater., V153, P790
[2]   Experimental study on structural performance of UHPC and UHPFRC columns confined with steel tube [J].
An Le Hoang ;
Fehling, Ekkehard ;
Lai, Binglin ;
Duc-Kien Thai ;
Nguyen Van Chau .
ENGINEERING STRUCTURES, 2019, 187 :457-477
[3]   Evaluation of axial strength in circular STCC columns using UHPC and UHPFRC [J].
An Le Hoang ;
Fehling, Ekkehard ;
Duc-Kien Thai ;
Chau Van Nguyen .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 153 :533-549
[4]  
[Anonymous], Concrete, reinforced and prestressed concrete structures
[5]  
[Anonymous], 2009, DIN EN 12390-3:2009-7
[6]  
[Anonymous], 2009, DIN EN 12390-6
[7]  
[Anonymous], 2014, ACI 318-14
[8]  
[Anonymous], 1990, ASTM, C.: 496-90
[9]  
[Anonymous], 2010, DIN EN 12350-8:2010-12
[10]  
[Anonymous], 2013, Model Code for Concrete Structures 2010