Fault Diagnosis in PMSM with Partitioned Stator Windings-Part I: Experimental Validation with Static Eccentricity

被引:1
作者
Armando Mazzoletti, Manuel [1 ]
Ruben Bossio, Guillermo [2 ]
Bossio, Jose M. [2 ]
Leidhold, Roberto [3 ]
机构
[1] UNaM, Fac Ingn, Lab Inv & Desarrollo Energla Elect LIDEE, Obera, Misiones, Argentina
[2] Consejo Nacl Invest Cient & Tecn, IITEMA UNRC, Grp Elect Aplicada GEA, Cordoba, Argentina
[3] Otto von Guericke Univ, Inst Elekt Energiesyst IESY, Magdeburgo, Germany
来源
2020 IEEE CONGRESO BIENAL DE ARGENTINA, ARGENCON | 2020年
关键词
Fault detection; PMSM; Static eccentricity; MAGNET SYNCHRONOUS MOTORS;
D O I
10.1109/ARGENCON49523.2020.9505552
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A signal-based strategy for static eccentricity (SE) detection in permanent magnet synchronous machines (PMSM) is proposed in this work. The effects of SE are analyzed from a model developed using a finite element method (FEM). SE detection is realized by evaluating the residual voltages (RV) obtained from the midpoint voltages measured in the middle of the windings of each phase. Unlike the methods based on motor current or voltage signature analysis (MCSA/MVSA), RVs allow to detect only the effects of an SE against other external problems that are usually found in industrial applications. Experimental laboratory results are presented which were obtained using bearings with eccentric bushings to generate different degrees of SE in the PMSM. The proposed strategy is validated by comparing the results obtained by FEM with the experimental tests for PMSM in different operating conditions, guaranteeing the correct diagnosis of SE.
引用
收藏
页数:7
相关论文
共 22 条
[1]   Interturn short-circuit fault diagnosis in PMSM with partitioned stator windings [J].
Armando Mazzoletti, Manuel ;
Bossio, Guillermo R. ;
Hernan De Angelo, Cristian .
IET ELECTRIC POWER APPLICATIONS, 2020, 14 (12) :2301-2311
[2]  
Bossio J., 2014, BIENN C ARG ARGENCON, P680
[3]   Rotor fault diagnosis in permanent magnet synchronous machine using the midpoint voltage of windings [J].
Bossio, Jose ;
Ruschetti, Cristian ;
Bossio, Guillermo ;
Verucchi, Carlos ;
De Angelo, Cristian .
IET ELECTRIC POWER APPLICATIONS, 2020, 14 (02) :256-261
[4]  
Duan Yao, 2012, IEEE POWER ENERGY SO
[5]   Magnetic field and vibration monitoring in permanent magnet synchronous motors under eccentricity fault [J].
Ebrahimi, B. M. ;
Faiz, J. .
IET ELECTRIC POWER APPLICATIONS, 2012, 6 (01) :35-45
[6]   Advanced Eccentricity Fault Recognition in Permanent Magnet Synchronous Motors Using Stator Current Signature Analysis [J].
Ebrahimi, Bashir Mahdi ;
Roshtkhari, Mehrsan Javan ;
Faiz, Jawad ;
Khatami, Seyed Vahid .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (04) :2041-2052
[7]   Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors [J].
Ebrahimi, Bashir Mahdi ;
Faiz, Jawad ;
Roshtkhari, Mehrsan Javan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4727-4739
[8]   Discernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors [J].
Goktas, Taner ;
Zafarani, Mohsen ;
Akin, Bilal .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (02) :585-594
[9]   On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDA [J].
Haddad, Reemon Z. ;
Strangas, Elias G. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (03) :924-934
[10]   Rotor UMP characteristics and vibration properties in synchronous generator due to 3D static air-gap eccentricity faults [J].
He, Yu-Ling ;
Sun, Yue-Xin ;
Xu, Ming-Xing ;
Wang, Xiao-Long ;
Wu, Yu-Cai ;
Vakil, Gaurang ;
Gerada, David ;
Gerada, Chris .
IET ELECTRIC POWER APPLICATIONS, 2020, 14 (06) :961-971