High-resolution retinal imaging system with dual deformable mirrors

被引:0
作者
Xiao, Fei [1 ,2 ,3 ]
Dai, Yun [1 ,3 ]
Zhao, Junlei [1 ,2 ,3 ]
Zhao, Haoxin [1 ,3 ]
Zhou, Hong [1 ,3 ]
Fan, Xinlong [1 ,3 ]
Zhang, Xiaojun [1 ,3 ]
Hu, Yiyun [1 ,3 ]
Zhang, Yudong [1 ,3 ]
机构
[1] Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, Sichuan
[2] University of Chinese Academy of Sciences, Beijing
[3] Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu, 610209, Sichuan
来源
Guangxue Xuebao/Acta Optica Sinica | 2015年 / 35卷 / 05期
关键词
Adaptive optics; Deformable mirrors; Eye aberration; Retinal imaging;
D O I
10.3788/AOS201535.0501004
中图分类号
学科分类号
摘要
How to effectively correct ocular aberrations which vary fast from person to person and improve the application scope of adaptive optics retinal imaging system is the biggest problem in clinical application. It is difficult for a single corrector to compensate both low order and high order ocular aberrations simultaneously. Due to the correction requirements of high order aberrations, a 169-element discrete piezoelectric deformable mirror with 3 millimeters spacing is successfully developed. Combined with a large stroke bimorph mirror, a retinal imaging system with two deformable mirrors is developed. The system can compensate low order aberrations up to ±4.5 diopters of defocus and ±3 diopters of cylindrical. High order Zernike aberrations up to the 8th order can also be corrected by this system. Both imaging quality and application scope are significantly improved. Taking the size of low order aberrations as inclusion criteria, a little sample is tested by the human retinal imaging experiment, and near diffraction-limited retinal images are achieved. The system has a clear application scope, which is convenient for future clinical application. ©, 2015, Chinese Optical Society. All right reserved.
引用
收藏
页数:8
相关论文
共 14 条
[1]  
Liang J., Williams D.R., Miller D.T., Supernormal vision and high-resolution retinal imaging through adaptive optics, J Opt Soc Am A, 14, 11, pp. 2884-2892, (1997)
[2]  
Williams D.R., Imaging single cells in the living retina, Vision Research, 51, 13, pp. 1379-1396, (2011)
[3]  
Thibos L.N., Hong X., Bradley A., Et al., Statistical variation of aberration structure and image quality in a normal population of healthy eyes, J Opt Soc Am A, 19, 12, pp. 2329-2348, (2002)
[4]  
Ling N., Zhang Y., Rao X., Et al., A small adaptive optical imaging system for cells of living human retina, Acta Optica Sinica, 24, 9, pp. 1153-1158, (2004)
[5]  
Niu S., Shen J., Liang C., Et al., High-resolution retinal imaging with micro adaptive optics system, Applied Optics, 50, 22, pp. 4365-4375, (2011)
[6]  
Zhou H., Guan C., Dai Y., Bimorph deformable mirrors for adaptive optics of human retinal imaging system, Acta Optica Sinica, 33, 2, (2013)
[7]  
Kong N., Li D., Xia M., Et al., Liquid crystal adaptive optics system for human retinal imaging operated on openloop and double-pulse mode, Acta Optica Sinica, 32, 1, (2012)
[8]  
Dalimier E., Dainty C., Barbur J.L., Effects of higher-order aberrations on contrast acuity as a function of light level, Journal of Modern Optics, 55, 4-5, pp. 791-803, (2008)
[9]  
Chen D.C., Jones S.M., Silva D.A., Et al., High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors, J Opt Soc Am A, 24, 5, pp. 1305-1312, (2007)
[10]  
Cense B., Gao W., Brown J.M., Et al., Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics, Optics Express, 17, 24, pp. 21634-21651, (2009)