Diagnosing transformer oil-paper insulation by hybrid equivalent circuit

被引:0
作者
Lin Z.-Y. [1 ]
Cai J.-D. [1 ]
机构
[1] College of Electrical Engineering and Automation, Fuzhou University, Fuzhou
来源
Dianji yu Kongzhi Xuebao/Electric Machines and Control | 2016年 / 20卷 / 03期
关键词
A hybrid equivalent circuit; Oil-paper insulation; Return voltage; Transformer;
D O I
10.15938/j.emc.2016.03.001
中图分类号
学科分类号
摘要
Aiming at the complexity of dielectric relaxation response of transformer oil-paper insulation, a hybrid equivalent circuit new model was established to characterize the relaxation process of oil-paper insulation system according to the characteristics of oil-paper insulation. According to theory analysis of hybrid equivalent circuit, formula of the hybrid equivalent circuit parameters and the recovery voltage were deduced. Test data of a transformer recovery voltage was adopted to verify the method, and then the test data of a transformer before and after being maintained was used to diagnose transformer oil-paper insulation system based on hybrid equivalent circuit. The results show that: the return voltage curve which is gained by the hybrid equivalent circuit method inosculates very well with those gained by the field measurements, and the hybrid equivalent circuit can diagnose aging of transformer oil-paper insulation dielectric accurately. © 2016, Editorial Department of Electric Machines and Control. All right reserved.
引用
收藏
页码:1 / 5
页数:4
相关论文
共 15 条
[1]  
Liu L., Liao R., Sun H., Et al., Investigation on properties and characteristics of oil-paper insulation in transformer during thermal degradation process, Transactions of China Electrotechnical Society, 24, 8, pp. 27-33, (2009)
[2]  
Cheng Y., Diao C., Liu S., Et al., Developing laws and severity diagnosis of partial discharge defects on oil-paper insulation, High Voltage Engineering, 39, 5, pp. 1061-1068, (2013)
[3]  
Chen Q., Wang Y., Gao W., Et al., The frequency range selection for measurement of partial discharge in transformer oil with UHF method and interference suppression, Electric Machines and Control, 10, 2, pp. 147-150, (2006)
[4]  
Gao Z., Wu G., Zhou L., Et al., Influence of moisture content on parameters of return voltage measurement in oil-paper insulation system of transformer, High Voltage Apparatus, 47, 4, pp. 37-41, (2011)
[5]  
Wang K., Cai J., Research on air gap influence on return voltage parameters for oil-paper insulation system, Journal of Electric Power Science and Technology, 28, 4, pp. 37-42, (2013)
[6]  
Jiang X., Zhang T., Huang Y., Simulation of transformer insulation polarization spectrum, Electric Power Automation Equipment, 31, 2, pp. 31-35, (2011)
[7]  
Liao R., Hao J., Yang L., Et al., Simulation and experimental study on frequency-domain dielectric spectroscopy of oil-paper insulation for transformers, Proceedings of the CSEE, 22, pp. 113-119, (2010)
[8]  
Gan L., Cai J., Zhang K., Study on parameters identification for equivalent circuit of oil-paper insulation system based on RVM, Journal of Electric Power Science and Technology, 28, 3, pp. 71-76, (2013)
[9]  
Li J., Hu Q., Wu L., Et al., Simulation study of polarization and depolarization current measurements technology, Shaanxi Electric Power, 39, 4, pp. 1-5, (2011)
[10]  
Tang P., Yin Y., Wu J., Et al., Study of oil-paper insulated transformers' aging state based on depolarization current measurements, Advanced Technology of Electrical Engineering and Energy, 31, 4, pp. 39-42, (2012)