A Cuffless Blood Pressure Estimation Method Using Dimensionality Increasing and Two-Dimensional Convolution

被引:0
作者
Cui, Shouyi [1 ]
Yang, Guowei [1 ]
Guan, Jingxuan [1 ]
He, Yuheng [1 ]
Zhou, Xuefang [1 ]
Bi, Meihua [1 ]
Shen, Hanghai [2 ]
Xu, Yuansheng [3 ]
机构
[1] Hangzhou Dianzi Univ, Sch Commun Engn, Hangzhou 310018, Peoples R China
[2] Yipeng St Community Healthcare Ctr, Hangzhou 311225, Peoples R China
[3] Westlake Univ, Affiliated Hangzhou Peoples Hosp 1, Sch Med, Dept Emergency, Hangzhou 310006, Peoples R China
基金
中国国家自然科学基金;
关键词
Estimation; Electrocardiography; Accuracy; Convolution; Feature extraction; Convolutional neural networks; Training; MIMICs; Monitoring; Hypertension; Blood pressure; electrocardiography (ECG); photoplethysmography (PPG); dimensionality increasing; two-dimensional convolution; model pruning; MEASURING DEVICES; RECURRENCE PLOTS; SOCIETY;
D O I
10.1109/JBHI.2025.3551613
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Blood pressure (BP) monitoring is a basic way to evaluate hypertension and its related diseases. Since non-invasive measurement with cuff is not real-time and invasive measurement with vessel puncture is not practical in daily life, this paper proposes a cuffless BP estimation method using two-dimensional (2D) convolution. Dimensionality increasing algorithms including recurrence plot and Gramian angular field are firstly used to convert electrocardiography (ECG) and photoplethysmography (PPG) signals into 2D images. New fused Gramian angular field (FGAF) and combined Gramian angular field (CGAF) are proposed to reduce the input 2D images data and enhance the signals' relevance. The converted images are used to train 2D convolutional models and estimate BP values. The 2D models effectively improved BP estimation accuracy, and the accuracy of the VGGNet 2D model using Gramian angular difference field (GADF) is improved by 38% compared with the corresponding 1D convolutional model. The proposed FGAF and CGAF can reduce input data by 50% while maintaining estimation accuracy, and the minimum mean absolute errors of the estimated BP values could reach 2.71 and 1.74 mmHg for systolic and diastolic blood pressures, respectively. To reduce model size, the VGGNet BP estimation model is pruned by reducing 60% of channel numbers while maintain the model performance. The pruned VGGNet model using the FGADF is then fine-tuned and validated by MIMIC-III dataset to show its generalization ability. Furthermore, a simple monitor system is built to show the feasibility of signal collection and BP estimation.
引用
收藏
页码:4769 / 4783
页数:15
相关论文
共 38 条
[1]   A hybrid neural network for continuous and non-invasive estimation of blood pressure from raw electrocardiogram and photoplethysmogram waveforms [J].
Baker, Stephanie ;
Xiang, Wei ;
Atkinson, Ian .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 207
[2]   Characteristic Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation [J].
Baktash, Seddigheh ;
Forouzanfar, Mohamad ;
Batkin, Izmail ;
Bolic, Miodrag ;
Groza, Voicu Z. ;
Ahmad, Saif ;
Dajani, Hilmi R. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (05) :1263-1270
[3]   Deep learning and time series-to-image encoding for financial forecasting [J].
Barra, Silvio ;
Carta, Salvatore Mario ;
Corriga, Andrea ;
Podda, Alessandro Sebastian ;
Recupero, Diego Reforgiato .
IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2020, 7 (03) :683-692
[4]   Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters [J].
Carlson, Charles ;
Turpin, VanessaRose ;
Suliman, Ahmad ;
Ade, Carl ;
Warren, Steve ;
Thompson, David E. .
SENSORS, 2021, 21 (01) :1-13
[5]   Non-intrusive Load Monitoring Using Gramian Angular Field Color Encoding in Edge Computing [J].
Chen, Junfeng ;
Wang, Xue .
CHINESE JOURNAL OF ELECTRONICS, 2022, 31 (04) :595-603
[6]   NeST: A Neural Network Synthesis Tool Based on a Grow-and-Prune Paradigm [J].
Dai, Xiaoliang ;
Yin, Hongxu ;
Jha, Niraj K. .
IEEE TRANSACTIONS ON COMPUTERS, 2019, 68 (10) :1487-1497
[7]   RECURRENCE PLOTS OF DYNAMIC-SYSTEMS [J].
ECKMANN, JP ;
KAMPHORST, SO ;
RUELLE, D .
EUROPHYSICS LETTERS, 1987, 4 (09) :973-977
[8]   Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method [J].
Gesche, Heiko ;
Grosskurth, Detlef ;
Kuechler, Gert ;
Patzak, Andreas .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) :309-315
[9]   Understanding Bland Altman analysis [J].
Giavarina, Davide .
BIOCHEMIA MEDICA, 2015, 25 (02) :141-151
[10]   PULSE-WAVE VELOCITY AS A MEASURE OF BLOOD-PRESSURE CHANGE [J].
GRIBBIN, B ;
STEPTOE, A ;
SLEIGHT, P .
PSYCHOPHYSIOLOGY, 1976, 13 (01) :86-90