Peritoneal Dialysis in Patients Supported by Left Ventricular Assist Device

被引:0
作者
Darbaidze, Zurab [1 ]
Schmack, Bastian [1 ]
Dogan, Guenes [1 ]
Merzah, Ali Saad [1 ]
Gabriel, Maria M. [2 ]
Goerler, Adelheid [1 ]
Popov, Aron-Frederik [1 ]
Weymann, Alexander [1 ]
Ruhparwar, Arjang [1 ]
Schmitto, Jan D. [1 ]
Hanke, Jasmin S. [1 ]
机构
[1] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Hannover, Germany
[2] Hannover Med Sch, Dept Neurol, Hannover, Germany
关键词
APD; CAPD; cardiorenal syndrome; continuous ambulatory peritoneal dialysis; heart failure; kidney failure; left ventricular assist device; LVAD; peritoneal dialysis; PATHOPHYSIOLOGY; HEMODIALYSIS; OUTCOMES;
D O I
10.1111/aor.14970
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
IntroductionTerminal heart failure is often associated with end-stage kidney disease. Due to advantages concerning patient independence, peritoneal dialysis (PD) is an alternative to conventional hemodialysis treatment. As left ventricular assist device implantations continuously increase, data on combined PD and LVAD is rare. We present the first and largest cohort study on this exclusive patient cohort.MethodsA retrospective study was conducted on patients who underwent LVAD implantation at a high-volume heart failure center from 2000 to 2024. Adverse events were analyzed according to the INTERMACS classification.ResultsA total of nine patients were identified as undergoing PD on LVAD therapy. Mean age at the time of LVAD implantation was 67 years. Main cause of kidney disease was cardio-renal syndrome (67%). In all patients, PD therapy was established before LVAD implantation. Mean time on PD before LVAD implantation was 72 months. None of the patients were weaned from dialysis nor were converted to conventional dialysis. Four patients experienced driveline infection. Three patients suffered an infection of their PD catheter. A combination of PD and DL infection was detected in two cases. None of these infections were associated with the same pathogens. Mean survival after LVAD + PD was 56.5 months.ConclusionPeritoneal dialysis has advantages over hemodialysis including fewer bloodstream infections, fewer hemodynamic shifts, and the comfort of the ambulant setting. This study illustrates that PD in LVAD patients is feasible and long-term support up to several years is achievable without major complications.
引用
收藏
页码:1062 / 1066
页数:5
相关论文
共 17 条
[1]   Peritoneal Dialysis Following Left Ventricular Assist Device Placement and Kidney Recovery: A Case Report [J].
Ajuria, Michael ;
Franz, Douglas D. ;
Morris, John T., III ;
Abra, Graham ;
Hussein, Wael F. .
KIDNEY MEDICINE, 2021, 3 (03) :438-441
[2]   Outcomes Associated With Left Ventricular Assist Devices Among Recipients With and Without End-stage Renal Disease [J].
Bansal, Nisha ;
Hailpern, Susan M. ;
Katz, Ronit ;
Hall, Yoshio N. ;
Tamura, Manjula K. ;
Kreuter, William ;
O'Hare, Ann M. .
JAMA INTERNAL MEDICINE, 2018, 178 (02) :204-209
[3]   Cardio renal acute kidney injury: Epidemiology, presentation, causes, pathophysiology and treatment [J].
Di Lullo, Luca ;
Bellasi, Antonio ;
Russo, Domenico ;
Cozzolino, Mario ;
Ronco, Claudio .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 227 :143-150
[4]   Peritoneal dialysis and LVAD bridge to successful heart-kidney transplant [J].
Forcey, Dana S. ;
Manefield, Kye ;
Wilson, Scott .
PERITONEAL DIALYSIS INTERNATIONAL, 2023, 43 (03) :268-271
[5]   Outcomes Among Patients With Left Ventricular Assist Devices Receiving Maintenance Outpatient Hemodialysis: A Case Series [J].
Franz, Douglas D. ;
Hussein, Wael F. ;
Abra, Graham ;
Diskin, Charles D. ;
Duggal, Vishal ;
Teuteberg, Jeffrey J. ;
Chang, Tara, I ;
Schiller, Brigitte .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 77 (02) :226-234
[6]   Peritoneal Dialysis After Left Ventricular Assist Device Placement [J].
Guglielmi, Anthony A. ;
Guglielmi, Kelly E. ;
Bhat, Geetha ;
Siemeck, Roxanne ;
Tatooles, Antone J. .
ASAIO JOURNAL, 2014, 60 (01) :127-128
[7]   Left ventricular assist device patient maintained on home hemodialysis: A novel class of patients to the home dialysis population [J].
Hanna, Ramy M. ;
Cruz, Daniel ;
Selamet, Umut ;
Hasnain, Huma ;
Kwon, Murray ;
Baas, Arnold ;
Wilson, James .
HEMODIALYSIS INTERNATIONAL, 2018, 22 (03) :E36-E38
[8]   Peritoneal dialysis improves quality-of-the in a left ventricular assist device destination therapy patient-a case report [J].
Koppel, Claire J. ;
Jonker, Jacqueline T. ;
Michels, Wieneke M. ;
Beeres, Saskia L. M. A. .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2021, 5 (10)
[9]   Outcomes With Left Ventricular Assist Device in End-Stage Renal Disease: A Systematic Review [J].
Lakhdar, Sofia ;
Nassar, Mahmoud ;
Buttar, Chandan ;
Perez, Laura M. Guzman ;
Akbar, Shahzad ;
Zafar, Anoosh ;
Munira, Most .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
[10]   Peritoneal dialysis catheter placement technique and complications [J].
Peppelenbosch, Arnoud ;
van Kuijk, Willy H. M. ;
Bouvy, Nicole D. ;
van der Sande, Frank M. ;
Tordoir, Jan H. M. .
CLINICAL KIDNEY JOURNAL, 2008, 1 :IV23-IV28