Online Quality Assurance of Microchannels in Rollto-Roll by Optical Coherence Tomography

被引:0
作者
Lauri, Janne [1 ]
Liedert, Christina [2 ]
Liedert, Ralph [2 ]
Fabritius, Tapio [1 ]
机构
[1] Univ Oulu, Optoelect & Measurement Tech Res Unit, Oulu, Finland
[2] VTT Tech Res Ctr Finland, Oulu, Finland
来源
2020 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2020 | 2020年
基金
芬兰科学院;
关键词
non-destructive testing; surface topography; online measurement; profilometer; SURFACE-TOPOGRAPHY; INSPECTION;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Roll-to-roll (R2R) process is an emerging technology to manufacture printed electronics, microfluidics, biochemical sensors etc. The requirements for high quality and small tolerances at the manufacturing phase are of the essence for such products. To verify the quality and guarantee the high production yield, high speed, non-destructive testing methods are needed. In this paper, optical coherence tomography (OCT) device is used at the R2R-line to measure online hot embossed microchannel structures at speed of 1 m/min, which is typical for the hot embossing process. The channel's width and shape are determined along the web. The applicability of OCT for topography measurements is demonstrated in an actual R2R environment.
引用
收藏
页数:5
相关论文
共 17 条
[1]   Online monitoring of printed electronics by Spectral-Domain Optical Coherence Tomography [J].
Alarousu, Erkki ;
AlSaggaf, Ahmed ;
Jabbour, Ghassan E. .
SCIENTIFIC REPORTS, 2013, 3
[2]   Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography [J].
Cho, Nam Hyun ;
Jung, Unsang ;
Kim, Suhwan ;
Kim, Jeehyun .
SENSORS, 2012, 12 (08) :10395-10406
[3]  
Czajkowski J., 2012, Sub-micron resolution high-speed spectral domain optical coherence tomography in quality inspection for printed electronics, P84300, DOI [10.1117/12.922443, DOI 10.1117/12.922443]
[4]   Modified wavelength scanning interferometry for simultaneous tomography and topography of the cornea with Fourier domain optical coherence tomography [J].
Das, Susobhan ;
Liu, Chih-Hao ;
Singh, Manmohan ;
Twa, Michael D. ;
Larin, Kirill V. .
BIOMEDICAL OPTICS EXPRESS, 2018, 9 (09) :4443-4458
[5]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI [10.1088/0034-4885/66/2/204, 10.2184/lsj.31.635]
[6]   Nondestructive defect inspection for LCDs using optical coherence tomography [J].
Kim, Su-Hwan ;
Kim, Jee-Hyun ;
Kang, Shin-Won .
DISPLAYS, 2011, 32 (05) :325-329
[7]   Measuring flow dynamics in a microfluidic chip using optical coherence tomography with 1 μm axial resolution [J].
Lauri, J. ;
Czajkowski, J. ;
Myllyla, R. ;
Fabritius, T. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 43 :1-5
[8]   Effect of solvent lamination on roll-to-roll hot-embossed PMMA microchannels evaluated by optical coherence tomography [J].
Lauri, Janne ;
Liedert, Christina ;
Kokkonen, Annukka ;
Fabritius, Tapio .
MATERIALS RESEARCH EXPRESS, 2019, 6 (07)
[9]   Surface topography measurement by frequency sweeping digital holography [J].
Ledl, Vit ;
Psota, Pavel ;
Kavan, Frantisek ;
Matousek, Ondrej ;
Mokry, Pavel .
APPLIED OPTICS, 2017, 56 (28) :7808-7814
[10]   FOCUS-WAVELENGTH ENCODED OPTICAL PROFILOMETER [J].
MOLESINI, G ;
PEDRINI, G ;
POGGI, P ;
QUERCIOLI, F .
OPTICS COMMUNICATIONS, 1984, 49 (04) :229-233