Algorithm for using dual energy computed tomography to determine chemical composition: A feasibility study

被引:0
作者
Choi, Dong Hyeok [1 ,2 ,3 ]
Ahn, So Hyun [4 ,5 ]
Park, Kwangwoo [6 ]
Han, Min Cheol [3 ]
Kim, Jin Sung [1 ,2 ,3 ]
机构
[1] Yonsei Univ, Coll Med, Dept Med, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Med Phys & Biomed Engn Lab MPBEL, Seoul, South Korea
[3] Yonsei Canc Ctr, Heavy Ion Therapy Res, Dept Radiat Oncol, Seoul, South Korea
[4] Ewha Womans Univ, Ewha Med Res Inst, Sch Med, Seoul, South Korea
[5] Ewha Womans Univ, Coll Med, Dept Biomed Engn, Seoul, South Korea
[6] Yonsei Univ, Coll Med, Yongin Severance Hosp, Dept Radiat Oncol, Yongin, South Korea
基金
新加坡国家研究基金会;
关键词
EFFECTIVE ATOMIC-NUMBER; CT; TISSUE; SINGLE;
D O I
10.1371/journal.pone.0322805
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Using dual-energy computed tomography (CT), this study aims to develop an algorithm to identify the chemical constituents of an unknown material (compound or mixture) and improve the accuracy of material discrimination. The algorithm requires mass attenuation coefficients (MAC) that were obtained using a dual energy CT as an input, identifies the elemental composition, and then calculates its weight fraction. To evaluate the functionality of the developed algorithm, it was used to determine the chemical constituents for human tissues. Furthermore, the results were compared with those provided by the National Institute of Standards and Technology (NIST). We used dual energies 80/140 kVp for spectral CT scans, as inputs to the algorithm, in addition to a set of 50/80 and 80/100 keV for mono-energetic X-rays. The algorithm correctly determined the chemical constituent elements of unknown materials. Results were obtained for the fractional weights of each component for mono-energetic X-rays and spectral X-ray use. For mono-energetic X-rays, the differences were < 0.01% for compounds and 6.02% for mixture, respectively. For the spectral X-rays, the differences in 2.98% for compounds and 6.03% for mixtures, respectively. We developed an algorithm to determine the type and weight fraction of an element using the MAC of dual-energy CT. The algorithm can exclude the inherent uncertainty of SPR calculations and improve the accuracy of dose calculations in radiation therapy planning.
引用
收藏
页数:17
相关论文
共 25 条
[1]   Simultaneous characterization of electron density and effective atomic number for radiotherapy planning using stoichiometric calibration method and dual energy algorithms [J].
Birgani, Mohammad J. Tahmasebi ;
Mahdavi, Maziyar ;
Zabihzadeh, Mansour ;
Lotfi, Mehrzad ;
Mosleh-Shirazi, Mohammad A. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (03) :601-619
[2]   A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation [J].
Han, Dong ;
Siebers, Jeffrey V. ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2016, 43 (01) :600-612
[3]   Tissue decomposition from dual energy CT data for MC based dose calculation in particle therapy [J].
Huenemohr, Nora ;
Paganetti, Harald ;
Greilich, Steffen ;
Jaekel, Oliver ;
Seco, Joao .
MEDICAL PHYSICS, 2014, 41 (06)
[4]   Deriving the Effective Atomic Number with a Dual-Energy Image Set Acquired by the Big Bore CT Simulator [J].
Jung, Seongmoon ;
Kim, Bitbyeol ;
Kim, Jung-in ;
Park, Jong Min ;
Choi, Chang Heon .
JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2020, 45 (04) :171-177
[5]   NOTES ON USE OF PROPAGATION OF ERROR FORMULAS [J].
KU, HH .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1966, C 70 (04) :263-+
[6]   A general method to derive tissue parameters for Monte Carlo dose calculation with multi-energy CT [J].
Lalonde, Arthur ;
Bouchard, Hugo .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22) :8044-8069
[7]   Convolutional neural network based proton stopping-power-ratio estimation with dual-energy CT: a feasibility study [J].
Lee, H. Hc ;
Park, Y. K. ;
Duan, X. ;
Jia, X. ;
Jiang, S. ;
Yang, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21)
[8]   Carbon Ion Therapy: A Modern Review of an Emerging Technology [J].
Malouff, Timothy D. ;
Mahajan, Anita ;
Krishnan, Sunil ;
Beltran, Chris ;
Seneviratne, Danushka S. ;
Trifiletti, Daniel Michael .
FRONTIERS IN ONCOLOGY, 2020, 10
[9]   The potential of dual-energy computed tomography for quantitative decomposition of soft tissues to water, protein and lipid in brachytherapy [J].
Malusek, A. ;
Karlsson, M. ;
Magnusson, M. ;
Carlsson, G. Alm .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) :771-785
[10]  
McLean ID, 2012, IAEA Human Health Series, V19