Assessment of dose calculation accuracy of tigrt treatment planning system for physical wedged fields in radiotherapy

被引:0
作者
Farhood B. [1 ]
Toossi M.T.B. [2 ]
Soleymanifard S. [2 ]
机构
[1] Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad
[2] Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad
关键词
Accuracy; Dose; Radiotherapy; Treatment Planning; Wedge;
D O I
10.22038/ijmp.2016.7958
中图分类号
学科分类号
摘要
Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective of the present study was to quantify the dose calculation accuracy of TiGRT TPS for physical wedged fields in radiotherapy. Materials and Methods A Semiflex™ ionization chamber was used for dose measurements in a water phantom; TiGRT TPS was also applied for dose calculations. The central axis (i.e., high dose-small dose gradient), build-up (i.e., high dose-large dose gradient), off-axis (i.e., high dose-small dose gradient), and out-of-field (i.e., low dose-small dose gradient) regions were evaluated in this study. Finally, the confidence limit values were obtained to quantify the dose calculation accuracy of TPS in these regions. Results The confidence limit values for the central axis, build-up, off-axis, and out-of-field regions were 1.01, 8.62, 1.79, and 55.24, respectively. Furthermore, the results showed that TiGRT TPS underestimated the dose of build-up and out-of-field regions for most points. Conclusion According to the results of the present study, it can be concluded that the dose calculation accuracy of TiGRT TPS for physical wedged fields in the central axis, build-up, and off-axis regions is adequate, while it is insufficient for out-of-field regions.
引用
收藏
页码:146 / 153
页数:7
相关论文
共 24 条
[1]  
Ravichandran R., Has the time come for doing away with Cobalt-60 teletherapy for cancer treatments, J Med Phys, 34, 2, pp. 63-65, (2009)
[2]  
Maqbool M., Determination of transfer functions of MCP-200 alloy using 6 MV photon beam for beam intensity modulation, J Mechanics Med Biol, 4, 3, pp. 305-310, (2004)
[3]  
Maqbool M., Ahmad I., Spectroscopy of gadolinium ion and disadvantages of gadolinium impurity in tissue compensators and collimators, used in radiation treatment planning, Journal of Spectroscopy, 21, 4, pp. 205-210, (2007)
[4]  
Kutcher G.J., Burman C., Mohan R., Compensation in three-dimensional non-coplanar treatment planning, Int J Radiat Oncol Biol Phys, 20, 1, pp. 127-133, (1991)
[5]  
Jones A.O., Das I.J., Jones F.L., A Monte Carlo study of IMRT beamlets in inhomogeneous media, Med phys, 30, 3, pp. 296-300, (2003)
[6]  
Zhu X., Gillin M., Jursinic P., Lopez F., Grimm D., Rownd J., Comparison of dosimetric characteristics of Siemens virtual and physical wedges, Med phys, 27, 10, pp. 2267-2277, (2000)
[7]  
Cheng C.-W., Tang W.L., Das I.J., Beam characteristics of upper and lower physical wedge systems of Varian accelerators, Phys Med Biol, 48, 22, pp. 3667-3683, (2003)
[8]  
Popple R.A., Brezovich I.A., Duan J., Shen S., Pareek P.N., Ye S.-J., Determination of field size dependent wedge factors from a few selected measurements, J Appl Clin Med Phys, 6, 1, pp. 51-60, (2005)
[9]  
Niroomand-Rad A., Haleem M., Rodgers J., Obcemea C., Wedge factor dependence on depth and field size for various beam energies using symmetric and half-collimated asymmetric jaw settings, Med Phys, 19, 6, pp. 1445-1450, (1992)
[10]  
Ahmad M., Hussain A., Muhammad W., Rizvi S.Q.A., Studying wedge factors and beam profiles for physical and enhanced dynamic wedges, J Med Phys, 35, 1, pp. 33-41, (2010)