Visual Quality and Symptomatology Following Implantation of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens

被引:0
作者
Cano-Ortiz, Antonio [1 ,2 ]
Sanchez-Ventosa, Alvaro [1 ]
Gonzalez-Cruces, Timoteo [1 ]
Villalba-Gonzalez, Marta [1 ]
Aguilar-Salazar, Francisco Javier [1 ]
Prados-Carmona, Juan J. [3 ]
Carpena-Torres, Carlos [4 ]
Carracedo, Gonzalo [4 ]
Villarrubia, Alberto [1 ]
机构
[1] Hosp Arruzafa, Dept Anterior Segment Cornea & Refract Surg, Cordoba 14012, Spain
[2] Univ Loyola Andalucia, Dept Hlth & Biomed Sci, Seville 41703, Spain
[3] Reina Sofia Univ Hosp, Dept Ophthalmol, Cordoba 14004, Spain
[4] Univ Complutense Madrid, Dept Optometry & Vis, Ocupharm Res Grp, Madrid 28040, Spain
关键词
extended range; EDOF; defocus curve; visual acuity; contrast sensitivity; CONTRAST SENSITIVITY; VISION; ACUITY; RANGE;
D O I
10.3390/jcm14134460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: This study aimed to evaluate the visual quality and symptomatology of a non-diffractive extended depth-of-focus (EDoF) intraocular lens (IOL), the Elon 877PEY (Medicontur, Zs & aacute;mb & eacute;k, Hungary), three months after implantation. Methods: A cross-sectional case series study was conducted, with measurements taken three months post-implantation of the Elon IOL. A total of 56 implanted eyes from 28 patients (mean age: 64.5 +/- 9.5 years) were included in the statistical analysis. The variables analyzed to assess the effectiveness of the Elon IOL included high-contrast visual acuity, contrast sensitivity, the defocus curve, and visual symptoms. Results: Three months after implantation, the mean residual sphere was 0.00 +/- 0.33 D, while the mean residual cylinder was -0.25 +/- 0.41 D. Without correction, patients achieved monocular decimal visual acuity values of 0.94 +/- 0.26 for distance, 0.79 +/- 0.17 for intermediate, and 0.58 +/- 0.15 for near vision. The mean uncorrected contrast sensitivity was 1.61 +/- 0.15 log. The defocus curve showed visual acuity exceeding 0.80 decimal (0.10 logMAR) over a 2.00 D range and above 0.63 decimal (0.20 logMAR) over a 2.50 D range. The most frequently reported symptoms, with mild severity and bothersomeness, were glare, starbursts, halos, and focusing difficulties. Conclusions: Patients implanted with the Elon IOL achieved satisfactory visual quality at all distances, comparable to outcomes reported for other EDoF IOLs in the scientific literature.
引用
收藏
页数:9
相关论文
共 24 条
[1]   A Comparative Evaluation of Visual, Refractive, and Patient-Reported Outcomes of Three Extended Depth of Focus (EDOF) Intraocular Lenses [J].
Ang, Robert Edward ;
Picache, Gian Carlo S. ;
Rivera, Mark Christian R. ;
Lopez, Lord Ryan L. ;
Cruz, Emerson M. .
CLINICAL OPHTHALMOLOGY, 2020, 14 :2339-2351
[2]   Optical Assessment and Expected Visual Quality of Four Extended Range of Vision Intraocular Lenses [J].
Azor, Juan Antonio ;
Vega, Fidel ;
Armengol, Jesus ;
Millan, Maria S. .
JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (11) :688-+
[3]   A Comparative Evaluation of a New Generation of Diffractive Trifocal and Extended Depth of Focus Intraocular Lenses [J].
Cochener, Beatrice ;
Boutillier, Guillaume ;
Lamard, Mathieu ;
Auberger-Zagnoli, Claire .
JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (08) :507-+
[4]   Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular Lens [J].
Corbett, Dean ;
Black, Daniel ;
Roberts, Timothy V. ;
Cronin, Brendan ;
Gunn, David ;
Bala, Chandra ;
Versace, Patrick ;
Tsai, Linda ;
Papadatou, Eleni ;
Alarcon, Aixa ;
Vilupuru, Srividhya .
EYE, 2024, 38 (SUPPL 1) :9-14
[5]   Functional Classification of Intraocular Lenses Based on Defocus Curves: A Scoping Review and Cluster Analysis [J].
Fernandez, Joaquin ;
Ribeiro, Filomena ;
Rocha-de-Lossada, Carlos ;
Rodriguez-Vallejo, Manuel .
JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (02) :e108-e116
[6]   Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design [J].
Fernandez-Nunez, Sara ;
Perez-Sanz, Lidia ;
Gomez-Pedrero, Jose Antonio ;
Garcia-Montero, Maria ;
Albarran-Diego, Cesar ;
Garzon, Nuria .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (12) :3905-3913
[7]   Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Extended Depth-of-Focus Intraocular Lens [J].
Gil, Javier Ferrando ;
Irazola, Adela Churruca ;
Reparaz, Iraia ;
Lauzirika, Gorka ;
Martinez-Soroa, Itziar ;
Mendicute, Javier .
CLINICAL OPHTHALMOLOGY, 2024, 18 :3801-3813
[8]   Visual acuity and defocus curves with six multifocal intraocular lenses [J].
Gil, Miguel A. ;
Varon, Consuelo ;
Cardona, Genis ;
Buil, Jose A. .
INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (02) :393-401
[9]   Comparing Visual Acuity, Low Contrast Acuity and Contrast Sensitivity After Trifocal Toric and Extended Depth of Focus Toric Intraocular Lens Implantation [J].
Gundersen, Kjell G. ;
Potvin, Rick .
CLINICAL OPHTHALMOLOGY, 2020, 14 :1071-1078
[10]  
HIRVELA H, 1995, ACTA OPHTHALMOL SCAN, V73, P111