Minimum-Phase Property of the Hemodynamic Response Function, and Implications for Granger Causality in fMRI

被引:0
作者
Novelli, Leonardo [1 ]
Barnett, Lionel [2 ]
Seth, Anil K. [2 ,3 ]
Razi, Adeel [1 ,4 ,5 ]
机构
[1] Monash Univ, Sch Psychol Sci & Monash Biomed Imaging, Melbourne, Vic, Australia
[2] Univ Sussex, Sackler Ctr Consciousness Sci, Dept Informat, Brighton, England
[3] CIFAR, Program Brain Mind & Consciousness, Toronto, ON, Canada
[4] CIFAR, Azrieli Global Scholars Program, Toronto, ON, Canada
[5] UCL, Wellcome Ctr Human Neuroimaging, London, England
基金
欧洲研究理事会; 英国医学研究理事会; 澳大利亚研究理事会;
关键词
CEREBRAL BLOOD-VOLUME; NEURAL SYSTEMS; BALLOON MODEL; BRAIN; BOLD; FLOW; DECONVOLUTION; ACTIVATION; MECHANISM; DYNAMICS;
D O I
10.1002/hbm.70285
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Granger causality (GC) is widely used in neuroimaging to estimate directed statistical dependence between brain regions using time series of brain activity. A known problem is that fMRI measures brain activity indirectly via the blood-oxygen-level-dependent (BOLD) signal, which can distort GC estimates by introducing different time-to-peak responses across brain regions. However, how these distortions affect the validity of inferred connections is not fully understood. Previous studies have shown that false positives are not introduced if the haemodynamic response function (HRF) is minimum-phase; but whether the HRF is actually minimum-phase has remained contentious. Here, we address this issue by studying the transfer functions of three realistic biophysical models. We find that the minimum-phase condition is met for a wide range of physiologically plausible parameter values. Therefore, statistical testing of GC can be viable even if the HRF varies across brain regions, with the following two limitations. First, the minimum-phase condition is violated for parameter combinations that generate an initial dip in the HRF. Second, slow sampling of the BOLD signal (seconds) compared to the timescales of neural signal propagation (milliseconds) may still introduce spurious GC inferences. Beyond GC analysis, the closed-form expressions for the transfer functions of these popular HRF models are valuable for modeling fMRI time series since they balance mathematical tractability with biological plausibility.
引用
收藏
页数:11
相关论文
共 59 条
[1]   Spatiotemporal hemodynamic response functions derived from physiology [J].
Aquino, K. M. ;
Robinson, P. A. ;
Drysdale, P. M. .
JOURNAL OF THEORETICAL BIOLOGY, 2014, 347 :118-136
[2]  
Ashburner J., 2020, SPM12 Manual. 2464 of 4
[3]   Glial and neuronal control of brain blood flow [J].
Attwell, David ;
Buchan, Alastair M. ;
Charpak, Serge ;
Lauritzen, Martin ;
MacVicar, Brian A. ;
Newman, Eric A. .
NATURE, 2010, 468 (7321) :232-243
[4]   Detectability of Granger causality for subsampled continuous-time neurophysiological processes [J].
Barnett, Lionel ;
Seth, Anil K. .
JOURNAL OF NEUROSCIENCE METHODS, 2017, 275 :93-121
[5]   Granger Causality and Transfer Entropy Are Equivalent for Gaussian Variables [J].
Barnett, Lionel ;
Barrett, Adam B. ;
Seth, Anil K. .
PHYSICAL REVIEW LETTERS, 2009, 103 (23)
[6]  
Bossomaier T., 2016, INTRO TRANSFER ENTRO, P65, DOI [DOI 10.1007/978-3-319-43222-9, 10. 1007/978-3-319- 43222-9]
[7]   Linear systems analysis of functional magnetic resonance imaging in human V1 [J].
Boynton, GM ;
Engel, SA ;
Glover, GH ;
Heeger, DJ .
JOURNAL OF NEUROSCIENCE, 1996, 16 (13) :4207-4221
[8]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864
[9]   The physics of functional magnetic resonance imaging (fMRI) [J].
Buxton, Richard B. .
REPORTS ON PROGRESS IN PHYSICS, 2013, 76 (09)
[10]   Dynamic models of BOLD contrast [J].
Buxton, Richard B. .
NEUROIMAGE, 2012, 62 (02) :953-961