摘要
The mapping relationship of homography matrix between the image plane and the target plane was calculated by the rectangular corner points, the linear equation of the center line of the structured-light in the target plane was obtained. Based on the vanishing point theory, the coordinates of arbitrary points on structured-light in target line in camera coordinate system was obtained. The light plane equation was fitted by calibration points extracted from multiple images. Experiments show that the method can achieve a fast and an accurate calibration of structured-light plane parameters with the positioning accuracy at 0.437 mm, and suitable for the requirements on industrial field. Compared with the methods based on invariance of cross ratio, the proposed method is more universal which has a higher efficiency to extract calibration points and the target design is more simple. © 2015, Chinese Optical Society. All right reserved.
引用
收藏
页数:6
相关论文
共 11 条
[1]  
Dewar R., Self-generated targets for spatial calibration of structured light optical sectioning sensors with respect to an external coordinate system, Robots and Vision'88 Conference Proceedings, pp. 5-13, (1988)
[2]  
Duan F.-J., Liu F.-M., Ye S.-H., A new accurate method for the calibration of line structured light sensor, Chinese Journal of Scientific Instrument, 21, 1, pp. 108-110, (2000)
[3]  
Lin N., Ma Z., Hu Y., Et al., New method for calibration of line structure light vision sensor based on robot system, Transducer and Microsystem Technologies, 26, 9, pp. 101-103, (2007)
[4]  
Wei Z.-Z., Zhang G.-J., Xu Y., Calibration approach for structured lighted stripe vision sensor, Chinese Journal of Mechanical Engineering, 41, 2, pp. 210-214, (2005)
[5]  
Zhou F.-Q., Zhang G.-J., Complete calibration of a structured light stripe vision sensor through planar target of unknown orientations, Image and Vision Computing, 23, 1, pp. 59-67, (2005)
[6]  
Chen X.-Y., Ma Z., Wang Y., Et al., A simple method to calibrate parameters of the line structured light, Journal of Optoelectronics. Laser, 24, 3, pp. 563-568, (2013)
[7]  
Chen T.-F., Zhao J.-B., Wu X., New calibration method for line structured light sensor based on planar target, Acta Optica Sinica, 35, 1, (2015)
[8]  
Zhang Z.-Y., A flexible new technique for camera calibration, IEEE Transactions on Pattern Analysis and Machine Intelligence, 22, 11, pp. 1330-1334, (2000)
[9]  
Wu B., Zhu H.-Y., Xiao X.-T., Et al., Extraction of plane target image features based on homography matrix in visual measurement, Journal of Optoelectronics. Laser, 22, 8, pp. 1211-1215, (2011)
[10]  
Chen G.-J., Chen M.-G., Xiao Y.-Q., The new sub-pixel loacation algorithm based on Hough transform, Electronic Design Engineering, 18, 12, pp. 127-130, (2010)