An Investigation of Dosimetric Consequences of the Anatomic Changes at First Fraction in VMAT of Prostate Cancer Cases using Deformable Planning CT and KVCBCT Image Registration

被引:0
作者
Jassim, Hussam Hameed [1 ,2 ,3 ]
Nedaei, Hassan A. [1 ,2 ]
Banaee, Nooshin [4 ]
Geraily, Ghazale [1 ,2 ]
Kazemian, Ali [2 ]
机构
[1] Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran
[2] Radiation Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran
[3] Department of Radiotherapy Physics, General Al-Najaf Al-Ashraf Hospital, Najaf
[4] Medical Radiation Research Center, Central Tehran Branch, Islamic Azad University, Tehran
关键词
Cone-Beam Computed Tomography; Deformable Image Registration; Dose Distribution; Optical Flow; Prostatic Neoplasms; Radiotherapy;
D O I
10.31661/jbpe.v0i0.2212-1574
中图分类号
学科分类号
摘要
Background: Kilovoltage Cone Beam Computed Tomography (kVCBCT) is used for patient setup, monitoring the delivered dose, and adapting the treatment to changes in the patient’s condition. Radiation therapy has recently shifted from image guidance to dose guidance, resulting in accurately calculating the daily dose, calculated by re-simulating CT-based treatment planning, to increase the precision of the actual treatment dosage. The use of kVCBCT instead of re-simulated CT can simplify the patient pathway and reduce potential therapeutic errors by eliminating the need for additional simulation. Objective: The present study aimed to assess the dosimetric effects of anatomical changes on prostate tumors using Deformation Image Registration (DIR) and kVCBCT. Material and Methods: In this experimental study, eight patients with primary prostate cancer were treated with Volumetric Modulated Arc Therapy (VMAT), and kVCBCT images were obtained for each patient during the first treatment fraction. Both the planning CT (pCT) and kVCBCT images were imported into DIR software. The pCT was then deformed to the kVCBCT image and imported into a Treatment Planning System (TPS). A new contour was created on the deformed Computed Tomography (dCT) using Atlas-based Auto-segmentation (ABAS). Daily dCT plans were individu-ally created based on the same planning principles using the new contours and also denoted dCTp1 through dCTp8. The outcomes of dose calculations were compared using Dose Volume Histograms (DVH), including mean Planning Target Volume (PTV) doses at the prescribed dose and dose volume limitations for the bladder and rectal wall. Results: The mean doses to the PTV in the eight dCT-based plans were the same as those in the pCT-based plans. However, the mean doses to organs at risk in the dCT plans were different from those in the pCT plans. The mean doses to the bladder were on average 4% lower than those in the pCT plans, while the mean doses to the rectum were on average 8% higher than those in the pCT plans. Conclusion: The use of VMAT based on kilovoltage kVCBCT and Deformtion Image Registration (DIR) can lead to re-decreasing the dose to the bladder while increasing that to the rectum, with the same PTV dose coverage. © Journal of Biomedical Physics and Engineering.
引用
收藏
页码:221 / 230
页数:9
相关论文
共 17 条
[1]  
Marin Anaya V, Fairfoul J., Assessing the feasibil-ity of adaptive planning for prostate radiotherapy using Smartadapt deformable image registration, Med Eng Phys, 64, pp. 65-73, (2019)
[2]  
Rigaud B, Simon A, Castelli J, Lafond C, Acosta O, Haigron P, Et al., Deformable image registration for radiation therapy: principle, methods, applications and evaluation, Acta Oncol, 58, 9, pp. 1225-1237, (2019)
[3]  
Yan D, Vicini F, Wong J, Martinez A., Adaptive radiation therapy, Phys Med Biol, 42, 1, pp. 123-132, (1997)
[4]  
Oh S, Kim S., Deformable image registration in radiation therapy, Radiat Oncol J, 35, 2, pp. 101-111, (2017)
[5]  
Yang D, Chaudhari SR, Goddu SM, Pratt D, Khullar D, Deasy JO, El Naqa I., Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation, Med Phys, 36, 2, pp. 329-338, (2009)
[6]  
Qin A, Sun Y, Liang J, Yan D., Evaluation of online/ offline image guidance/adaptation approaches for prostate cancer radiation therapy, Int J Radiat Oncol Biol Phys, 91, 5, pp. 1026-1033, (2015)
[7]  
Giacometti V, Hounsell AR, McGarry CK., A review of dose calculation approaches with cone beam CT in photon and proton therapy, Phys Med, 76, pp. 243-276, (2020)
[8]  
Jassim H, Nedaei HA, Geraily G, Banaee N, Kazem-ian A., The geometric and dosimetric accuracy of kilovoltage cone beam computed tomography images for adaptive treatment: a systematic review, BJR Open, 5, 1, (2023)
[9]  
Yang D, Brame S, El Naqa I, Aditya A, Wu Y, Goddu SM, Et al., Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research, Med Phys, 38, 1, pp. 67-77, (2011)
[10]  
Brock KK, Mutic S, McNutt TR, Li H, Kessler ML., Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132, Medical Physics, 44, 7, pp. e43-e76, (2017)