Impact of Potential Moderating Factors on Absolute Test-Retest Reliability of Grip Strength Measurements in Healthy Populations: A Systematic Review with Meta-Analysis

被引:0
作者
Abe, Takashi [1 ,2 ]
Song, Jun Seob [3 ]
Dankel, Scott J. [4 ]
Viana, Ricardo B. [5 ]
Abe, Akemi [2 ]
Loenneke, Jeremy P. [6 ]
机构
[1] Juntendo Univ, Inst Hlth & Sports Sci & Med, Grad Sch Hlth & Sports Sci, Chiba, Japan
[2] Inst Trainol, Div Childrens Hlth & Exercise Res, Fukuoka, Japan
[3] Texas A&M Univ San Antonio, Dept Counseling Hlth & Kinesiol, San Antonio, TX USA
[4] Rowan Univ, Dept Hlth & Exercise Sci, Glassboro, NJ USA
[5] Univ Fed Ceara, Inst Phys Educ & Sports, Human Anat Lab, Fortaleza, Ceara, Brazil
[6] Univ Mississippi, Kevser Ermin Appl Physiol Lab, Dept Hlth Exercise Sci & Recreat Management, Oxford, MS USA
关键词
Dynamometer; handgrip; reproducibility; peak mus-cular strength; HANDGRIP STRENGTH; FITNESS TESTS; DETECTABLE CHANGE; PHYSICAL-FITNESS; REFERENCE VALUES; CHILDREN; VALIDITY; FEASIBILITY; DYNAMOMETRY; INSTRUMENTS;
D O I
10.52082/jssm.2025.543
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Grip strength, a biomarker, can be measured at any age; however, its values vary daily for each individual, which impacts the assessment. Absolute test-retest reliability (i.e., minimal difference, MD) is commonly defined as the variation in absolute values of measurements taken by a single person or instrument on the same item under identical conditions. Nevertheless, the potential moderators of absolute repeatability in grip strength measurements have not yet been fully elucidated. We conducted a systematic review with meta-analysis to examine the influence of potential moderating factors on the absolute test-retest repeatability of grip strength measurements in healthy populations. PubMed, Scopus, and SPORTDiscus databases were searched up to January 2025 following the PRISMA guidelines, and 48 studies were included in this review. Age, test-retest interval, and device were used as potential moderating factors; however, sex and sports experience were excluded due to the limited number of published articles. We found considerable variation among studies reporting MD and percentage of MD to measured value (%MD) across each age group. The mean MD (%MD) values were 1.9 kg (25.4%) in young children (<7 years old), 2.5 kg (13.8%) in children (7-10 years old), 4.2 kg (17.1%) in adolescents (10-18 years old), 4.0 kg (11.6%) in young adults (18-35 years old), and 4.7 kg (16.7%) in older adults (>60 years old). Neither age [effect size [ES]: 0.015 (95% confidence interval [CI]:-0.004, 0.035; p = 0.113) for MD and ES:-0.025 (95% CI:-0.089, 0.039; p = 0.439) for %MD], test-retest interval [ES: 0.006 (95% CI:-0.002, 0.013; p = 0.143) for MD and ES: 0.022 (95% CI:-0.001, 0.046; p = 0.065) for %MD] nor handgrip device (p = 0.752 for MD and p = 0.334 for %MD) served as significant moderators of MD and %MD reliability. Due to the limited number of studies, sex and sports experience were excluded from the analysis; as a result, their impacts remain unknown.
引用
收藏
页数:12
相关论文
共 73 条
[61]   Test-retest reliability of grip strength measurement in full elbow extension to evaluate maximum grip strength [J].
Savva, C. ;
Karagiannis, C. ;
Rushton, A. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (02) :183-186
[62]   Long-Term Determinants of Muscle Strength Decline: Prospective Evidence from the 22-Year Mini-Finland Follow-Up Survey [J].
Stenholm, Sari ;
Tiainen, Kristina ;
Rantanen, Taina ;
Sainio, Paivi ;
Heliovaara, Markku ;
Impivaara, Olli ;
Koskinen, Seppo .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2012, 60 (01) :77-85
[63]   Absolute reliability of measurements of muscle strength and physical performance measures in older people with high functional capacities [J].
Suzuki, Yoshikazu ;
Kamide, Naoto ;
Kitai, Yui ;
Ando, Masataka ;
Sato, Haruhiko ;
Yoshitaka, Shiba ;
Sakamoto, Miki .
EUROPEAN GERIATRIC MEDICINE, 2019, 10 (05) :733-740
[64]   Grip strength in children: Test-retest reliability using Grippit [J].
Svensson, E. ;
Waling, K. ;
Haeger-Ross, C. .
ACTA PAEDIATRICA, 2008, 97 (09) :1226-1231
[65]  
Tan B, 2001, J SPORT MED PHYS FIT, V41, P68
[66]   Measuring handgrip strength in school children: inter-instrument reliability between Takei and Jamar [J].
Trajkovic, Nebojsa ;
Rancic, Doroteja ;
Ilic, Tamara ;
Herodek, Romina ;
Korobeynikov, Georgiy ;
Pekas, Damir .
SCIENTIFIC REPORTS, 2024, 14 (01)
[67]   REFERENCE VALUES FOR 6-MINUTE WALK TEST AND HAND- GRIP STRENGTH IN HEALTHY HONG KONG CHINESE ADULTS [J].
Tsang, Raymond C. C. .
HONG KONG PHYSIOTHERAPY JOURNAL, 2005, 23 (01) :6-12
[68]   Validity, reliability and test-retest study of Grip strength measurement in two positions with two dynamometers: Jamar® Plus and K-Force® Grip [J].
Uysal, Cildan ;
Tonak, H. A. ;
Kitis, A. .
HAND SURGERY & REHABILITATION, 2022, 41 (03) :305-310
[69]   Test-Retest Reliability and Sensitivity of Common Strength and Power Tests over a Period of 9 Weeks [J].
Venegas-Carro, Maria ;
Kramer, Andreas ;
Moreno-Villanueva, Maria ;
Gruber, Markus .
SPORTS, 2022, 10 (11)
[70]  
Villafane Jorge H, 2016, Hand (N Y), V11, P54, DOI [10.1177/1558944715614852, 10.1177/1558944715614852]