Concerns arising from the calculation of the apnea-hypopnea index during CPAP-telemonitoring of patients with obstructive sleep apnea

被引:0
作者
Vidal, Celia [1 ,2 ]
Mallet, Jean-Pierre [2 ,3 ,4 ]
Skinner, Sarah [5 ]
Gilson, Raphael [2 ]
Gaubert, Olivier [2 ]
Prigent, Arnaud [6 ]
Gagnadoux, Frederic [7 ]
Bourdin, Arnaud [2 ,3 ,4 ]
Molinari, Nicolas [1 ,2 ]
Jaffuel, Dany [2 ,3 ,4 ]
机构
[1] Montpellier Univ, PreMEd INRIA, CHU Montpellier, IDESP,INSERM, Montpellier, France
[2] Grp Adene, Montpellier, France
[3] Montpellier Univ Hosp, Arnaud de Villeneuve Hosp, Dept Resp Dis, Montpellier, France
[4] Montpellier Univ, CNRS UMR9214, PhyMedExp, INSERM U 1046, Montpellier, France
[5] CHU Montpellier, Montpellier, France
[6] Polyclin St Laurent, Grp Med Pneumol, Rennes, France
[7] Univ Hosp Angers, Dept Resp & Sleep Med, Angers, France
关键词
CPAP; AHI(flow); Telemonitoring; POSITIVE AIRWAY PRESSURE; ADHERENCE;
D O I
10.1186/s12931-025-03324-4
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Continuous Positive Airway Pressure (CPAP) telemonitoring is increasingly important in managing obstructive sleep apnea (OSA). The Apnea-Hypopnea Index reported by CPAP devices (AHI(flow)) is used as a key indicator of treatment effectiveness. However, discrepancies in AHI(flow) calculation rules between manufacturers may affect clinical decision-making. No prior studies have investigated whether manufacturers' choices to exclude certain apnea-hypopnea events from the AHI(flow) calculation may influence the number of patients presenting an AHI(flow) alert. The aim of this proof-of-concept study was not to compare the manufacturers with each other, but to evaluate, for each manufacturer, how the different possible ways of calculating AHI(flow) influence the percentage of alert cases. Methods We conducted a retrospective analysis of 13,764 CPAP-treated OSA patients monitored on October 2, 2023. AHI(flow) calculations were evaluated according to manufacturer-specific rules. When possible, we assessed the impact of excluding central hypopneas, events during major leaks, and/or ramp periods on the percentage of patients crossing the consensual AHI(flow) alert threshold of >= 10 events/h. Results We identified significant disparities in AHI(flow) calculations between manufacturers, which lead to significant differences in the number of patients flagged as being in an alert state. Excluding central hypopneas reduced the number of alert cases by 50%, while excluding apneas/hypopneas during major leaks or ramp periods reduced alerts by 20%. Conclusions Our proof-of-concept study highlights inconsistencies in AHI(flow) calculations among CPAP manufacturers, raising concerns about patient care. Establishing standardized AHI(flow) calculation criteria is essential to ensuring accurate monitoring and optimal patient safety.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Partial failure of CPAP treatment for sleep apnoea: Analysis of the French national sleep database [J].
Bailly, Sebastien ;
Daabek, Najeh ;
Jullian-Desayes, Ingrid ;
Joyeux-Faure, Marie ;
Sapene, Marc ;
Grillet, Yves ;
Borel, Jean-Christian ;
Tamisier, Renaud ;
Pepin, Jean-Louis .
RESPIROLOGY, 2020, 25 (01) :104-111
[2]   Apnoea-hypopnoea indices determined via continuous positive airway pressure (AHI-CPAPflow) versus those determined by polysomnography (AHI-PSGgold): a protocol for a systematic review and meta-analysis [J].
Bertelli, Fanny ;
Suehs, Carey Meredith ;
Mallet, Jean Pierre ;
Rotty, Marie Caroline ;
Pepin, Jean Louis ;
Gagnadoux, Frederic ;
Matzner-Lober, Eric ;
Bourdin, A. ;
Molinari, Nicolas ;
Jaffuel, Dany .
BMJ OPEN, 2021, 11 (05)
[3]   Australasian Sleep Association 2024 guidelines for sleep studies in adults [J].
Ellender, Claire M. ;
Ruehland, Warren R. ;
Duce, Brett ;
Joyce, Rosemarie ;
Worsnop, Christopher ;
Mercer, Jeremy ;
Naughton, Matthew ;
Hukins, Craig A. ;
Wheatley, John ;
Cunnington, David .
SLEEP, 2024, 47 (10)
[4]  
Jaffuel D., 2024, Medecine Du Sommeil, V21, P106
[5]   Accuracy of continuous positive airway pressure devices: the devil is in the details, the best is yet to come [J].
Jaffuel, Dany ;
Mallet, Jean-Pierre ;
Sabil, AbdelKebir .
SLEEP AND BREATHING, 2023, 27 (04) :1651-1654
[6]   Treatment of sleep-disordered breathing with positive airway pressure devices: technology update [J].
Johnson, Karin Gardner ;
Johnson, Douglas Clark .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 :425-437
[7]  
Launois-Rollinat S., 2024, Medecine Du Sommeil, V21, P76
[8]   Continuous positive airway pressure device detects atrial fibrillation induced central sleep apnoea [J].
Light, Matthew ;
Orr, Jeremy E. ;
Malhotra, Atul ;
Owens, Robert L. .
LANCET, 2018, 392 (10142) :160-160
[9]   Trajectories of Emergent Central Sleep Apnea During CPAP Therapy [J].
Liu, Dongquan ;
Armitstead, Jeff ;
Benjafield, Adam ;
Shao, Shiyun ;
Malhotra, Atul ;
Cistulli, Peter A. ;
Pepin, Jean-Louis ;
Woehrle, Holger .
CHEST, 2017, 152 (04) :751-760
[10]   Apnea-hypopnea index supplied by CPAP devices: time for standardization? [J].
Midelet, Alphanie ;
Borel, Jean-Christian ;
Tamisier, Renaud ;
Le Hy, Ronan ;
Schaeffer, Marie-Caroline ;
Daabek, Najeh ;
Pepin, Jean-Louis ;
Bailly, Sebastien .