An innovative lever-based isolator with quasi-zero stiffness properties for applications in mechanical control systems

被引:0
作者
Baduidana, Marcial [1 ,2 ]
Yaleu, Thomas Bell Djuitchou [3 ,4 ]
Nbendjo, Blaise Romeo Nana [3 ,4 ]
Kenfack-Jiotsa, Aurelien [1 ,2 ,5 ]
机构
[1] Univ Yaounde I, Fac Sci, Dept Phys, Lab Mech Mat & Struct, POB 812, Yaounde, Cameroon
[2] Univ Yaounde I, Higher Teacher Training Coll, Dept Phys, Nonlinear & Complex Syst Phys Grp, POB 47, Yaounde, Cameroon
[3] Univ Yaounde I, Fac Sci, Lab Modelling & Simulat Engn Biomimet & Prototypes, POB 812, Yaounde, Cameroon
[4] Univ Bertoua, Fac Sci, Dept Phys, Lab Nonlinear Dynam & Complex,Syst, POB 416, Bertoua, Cameroon
[5] Univ Yaounde I, Higher Teacher Training Coll, Dept Phys, POB 47, Yaounde, Cameroon
关键词
Harmonic excitation; Vibration isolation; Quasi-zero stiffness; Lever mechanism; Force transmissibility; VIBRATION ISOLATOR; NONLINEAR STIFFNESS; TRANSMISSIBILITY; DESIGN; FORCE;
D O I
10.1007/s40430-025-05767-8
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The use of lever-type stiffness mechanism (LSM) in vibration isolation practice is minimal. Accordingly, the quasi-zero lever-type stiffness isolator (QZLSI) is proposed in this paper. The novelty of the proposed LSM is designed by connecting two identical stiffness springs by a pivoting lever to change the negative stiffness properties of the QZLSI. Thus, the quasi-zero lever-type stiffness condition is established, and the results analysis showed that increasing the lever ratio can reduce the stiffness of the QZLSI and expand the negative stiffness range, which increase the bearing capacity of the QZLSI. To illustrate this advantage, the QZLSI is used as vibrations isolation system of typical simply supported beam structure. The dynamic equation is established, and the analytical displacement response of the isolated beam is determined using the harmonic balance method. Then, the force transmissibility response is deduced. The response analysis showed that a smaller lever ratio is beneficial to reduce the peak force transmissibility in the resonant region and extend the isolation frequencies band. Therefore, the isolation performance comparison of the proposed QZLSI with respect to its classical counterpart QZSI when the excitation force amplitude ratio varies between 0.001 and 0.1 demonstrates that the QZLSI can reduce the peak force transmissibility from 66.22 to 17.94% and expand the isolated frequency band from 73.31 to 49.9%. These results are relevant to show the interest of the proposed isolation system in engineering practice.
引用
收藏
页数:16
相关论文
共 47 条
[21]   Multi-layer electromagnetic spring with tunable negative stiffness for semi-active vibration isolation [J].
Pu, Huayan ;
Yuan, Shujin ;
Peng, Yan ;
Meng, Kai ;
Zhao, Jinglei ;
Xie, Rongqing ;
Huang, Yining ;
Sun, Yi ;
Yang, Yang ;
Xie, Shaorong ;
Luo, Jun ;
Chen, Xuedong .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 121 :942-960
[22]  
Rivin E.I., 2003, PASSIVE VIBRATION IS
[23]   Theoretical design parameters for a quasi-zero stiffness magnetic spring for vibration isolation [J].
Robertson, Will S. ;
Kidner, M. R. F. ;
Cazzolato, Ben S. ;
Zander, Anthony C. .
JOURNAL OF SOUND AND VIBRATION, 2009, 326 (1-2) :88-103
[24]  
Seto K., 1985, Trans Jpn Soc Mech Eng Ser C, V51, P1454
[25]   Performance analysis of a nonlinear inerter-based vibration isolator with inerter embedded in a linkage mechanism [J].
Shi, Baiyang ;
Dai, Wei ;
Yang, Jian .
NONLINEAR DYNAMICS, 2022, 109 (02) :419-442
[26]   A novel lever-type inerter-based vibration absorber [J].
Su, Ning ;
Bian, Jing ;
Chen, Zhaoqing ;
Xia, Yi .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2023, 254
[27]   Analysis and design of a nonlinear stiffness and damping system with a scissor-like structure [J].
Sun, Xiuting ;
Jing, Xingjian .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2016, 66-67 :723-742
[28]   Vibration isolation via a scissor-like structured platform [J].
Sun, Xiuting ;
Jing, Xingjian ;
Xu, Jian ;
Cheng, Li .
JOURNAL OF SOUND AND VIBRATION, 2014, 333 (09) :2404-2420
[29]   Beneficial stiffness design of a high-static-low-dynamic-stiffness vibration isolator based on static and dynamic analysis [J].
Wang, Xiaojie ;
Liu, Hui ;
Chen, Yinqi ;
Gao, Pu .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 142 :235-244
[30]   The impact of PD-L1 N-linked glycosylation on cancer therapy and clinical diagnosis [J].
Wang, Ying-Nai ;
Lee, Heng-Huan ;
Hsu, Jennifer L. ;
Yu, Dihua ;
Hung, Mien-Chie .
JOURNAL OF BIOMEDICAL SCIENCE, 2020, 27 (01)