An alternative real-time fluorescence reverse transcription loop-mediated isothermal amplification assay for the rapid detection of SARS-CoV-2

被引:0
作者
Rudeeaneksin, Janisara [1 ]
Klayut, Wiphat [1 ]
Phetsuksiri, Benjawan [1 ,2 ]
Uppapong, Ballang [3 ]
Wongchai, Thanee [4 ]
Chuenchom, Nuttagarn [4 ]
机构
[1] NIH, Minist Publ Hlth, Dept Med Sci, Nonthaburi 11000, Thailand
[2] Minist Publ Hlth, Dept Med Sci, Med Sci Tech Off, Nonthaburi, Thailand
[3] Minist Publ Hlth, Dept Med Sci, Adm Off, Nonthaburi, Thailand
[4] Mae Sot Gen Hosp, Minist Publ Hlth, Tak, Thailand
来源
REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO | 2025年 / 67卷
关键词
COVID-19; SARS-CoV-2; RT-LAMP; RT-PCR; Fluorescence;
D O I
10.1590/S1678-9946202567037
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
COVID-19, caused by SARS-CoV-2 virus infection, remains a public health concern in many countries. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a rapid and cost-effective alternative test for COVID-19 diagnosis. In this study, we developed and evaluated a real-time RT-LAMP (rRT-LAMP) assay coupled with a melting curve analysis to detect SARS-CoV-2. The reaction was carried out in a real-time thermal cycler at 63 degrees C for 45 min to amplify the region of SARS-CoV-2 orf8; real-time monitoring of amplification was performed by fluorescence detection. The performance was assessed by comparing it to a real-time reverse transcription-polymerase reaction (rRT-PCR) as a reference. The rRT-LAMP could detect as few as 15 copies of SARS-CoV-2 RNA per reaction. Positive results appeared within 30 min, while the melting-temperature analysis could verify the amplification specificity. No positive results from non-SARS-CoV-2 templates and no mis-amplification were observed. The comparative analysis using 262 RNA extracted from nasopharyngeal swab samples revealed the overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) of the rRT-LAMP at 88.55% (95% CI: 77.52-100%), 84.13% (95% CI: 71.56-98.27%), 100% (95% CI: 78.38-100%), 100% (95% CI: 85.06-100%), and 70.87% (95% CI: 55.55-89.11%), respectively. The greatest sensitivity was as high as 98-100% for specimens with threshold rRT-PCR cycle (Ct) values of less than 30 cycles. Overall, this rRT-LAMP showed good performance for the rapid detection of SARS-CoV-2. It is proposed as a potential method for real-time amplification detection, offering increased laboratory capacity for SARS-CoV-2 testing in a cost-effective and timely manner.
引用
收藏
页数:11
相关论文
共 30 条
[1]   Review of current in vitro COVID-19 diagnostics methods [J].
Al-Omari, Mariam M. ;
Qaqish, Arwa ;
Omeish, Haya Abdallah Fandi ;
Najadat, Angam Ayyoub Ali ;
Mahasneh, Fatimah ;
Al-Tamimi, Mohammad ;
Abbas, Manal Mohammad ;
Al-Qaoud, Khaled .
JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2022, 16 (09) :1376-1384
[2]   Colorimetric and fluorometric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for diagnosis of SARS-CoV-2 [J].
Alhamid, Galyah ;
Tombuloglu, Huseyin ;
Motabagani, Dalal ;
Motabagani, Dana ;
Rabaan, Ali A. ;
Unver, Kubra ;
Dorado, Gabriel ;
Al-Suhaimi, Ebtesam ;
Unver, Turgay .
FUNCTIONAL & INTEGRATIVE GENOMICS, 2022, 22 (06) :1391-1401
[3]   A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples [J].
Amaral, Catarina ;
Antunes, Wilson ;
Moe, Elin ;
Duarte, Americo G. ;
Lima, Luis M. P. ;
Santos, Cristiana ;
Gomes, Ines L. ;
Afonso, Goncalo S. ;
Vieira, Ricardo ;
Teles, Helena Sofia S. ;
Reis, Marisa S. ;
Ramalho da Silva, Manuel A. ;
Henriques, Ana Margarida ;
Fevereiro, Miguel ;
Ventura, M. Rita ;
Serrano, Monica ;
Pimentel, Catarina .
SCIENTIFIC REPORTS, 2021, 11 (01)
[4]   Advances in RT-LAMP for COVID-19 testing and diagnosis [J].
Choi, Gihoon ;
Moehling, Taylor J. ;
Meagher, Robert J. .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2023, :9-28
[5]   Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern) [J].
Corman, Victor M. ;
Landt, Olfert ;
Kaiser, Marco ;
Molenkamp, Richard ;
Meijer, Adam ;
Chu, Daniel K. W. ;
Bleicker, Tobias ;
Bruenink, Sebastian ;
Schneider, Julia ;
Schmidt, Marie Luisa ;
Mulders, Daphne G. J. C. ;
Haagmans, Bart L. ;
van der Veer, Bas ;
van den Brink, Sharon ;
Wijsman, Lisa ;
Goderski, Gabriel ;
Romette, Jean-Louis ;
Ellis, Joanna ;
Zambon, Maria ;
Peiris, Malik ;
Goossens, Herman ;
Reusken, Chantal ;
Koopmans, Marion P. G. ;
Drosten, Christian .
EUROSURVEILLANCE, 2020, 25 (03) :23-30
[6]   Limit of detection in different matrices of 19 commercially available rapid antigen tests for the detection of SARS-CoV-2 [J].
Cubas-Atienzar, Ana, I ;
Kontogianni, Konstantina ;
Edwards, Thomas ;
Wooding, Dominic ;
Buist, Kate ;
Thompson, Caitlin R. ;
Williams, Christopher T. ;
Patterson, Edward, I ;
Hughes, Grant L. ;
Baldwin, Lisa ;
Escadafal, Camille ;
Sacks, Jilian A. ;
Adams, Emily R. .
SCIENTIFIC REPORTS, 2021, 11 (01)
[7]   Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection [J].
Dinnes, Jacqueline ;
Sharma, Pawana ;
Berhane, Sarah ;
van Wyk, Susanna S. ;
Nyaaba, Nicholas ;
Domen, Julie ;
Taylor, Melissa ;
Cunningham, Jane ;
Davenport, Clare ;
Dittrich, Sabine ;
Emperador, Devy ;
Hooft, Lotty ;
Leeflang, Mariska M. G. ;
McInnes, Matthew D. F. ;
Spijker, Rene ;
Verbakel, Jan Y. ;
Takwoingi, Yemisi ;
Taylor-Phillips, Sian ;
Van den Bruel, Ann ;
Deeks, Jonathan J. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (07)
[8]   Recent advances in point of care testing for COVID-19 detection [J].
Fernandes, Renata Salgado ;
Silva, Juliana de Oliveira ;
Gomes, Karina Braga ;
Azevedo, Ricardo Bentes ;
Townsend, Danyelle M. ;
Sabino, Adriano de Paula ;
Branco de Barros, Andre Luis .
BIOMEDICINE & PHARMACOTHERAPY, 2022, 153
[9]   RT-LAMP for rapid diagnosis of coronavirus SARS-CoV-2 [J].
Huang, Wei E. ;
Lim, Boon ;
Hsu, Chia-Chen ;
Xiong, Dan ;
Wu, Wei ;
Yu, Yejiong ;
Jia, Huidong ;
Wang, Yun ;
Zeng, Yida ;
Ji, Mengmeng ;
Chang, Hong ;
Zhang, Xiuming ;
Wang, Hui ;
Cui, Zhanfeng .
MICROBIAL BIOTECHNOLOGY, 2020, 13 (04) :950-961
[10]   Diagnostic utility and validation of a newly developed real time loop mediated isothermal amplification method for the detection of SARS CoV-2 infection [J].
Iqbal, Bushran N. ;
Arunasalam, Shiyamalee ;
Divarathna, Maduja V. M. ;
Jabeer, Aaom ;
Sirisena, Pdnn ;
Senaratne, Thamarasi ;
Muthugala, Rohitha ;
Noordeen, Faseeha .
JOURNAL OF CLINICAL VIROLOGY PLUS, 2022, 2 (03)