Influence of bone material behavior assumption on finite element-predicted tibia-implant micromotions in total ankle replacement

被引:0
作者
Johnson, Joshua E. [1 ]
Anderson, Donald D. [1 ,2 ]
机构
[1] Univ Iowa, Dept Orthoped & Rehabil, North Liberty, IA 52317 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
Finite element analysis; Linear elastic bone material; Elastic-plastic bone material; Total ankle replacement; Micromotions; STRENGTH; INGROWTH; LOAD;
D O I
10.1016/j.jbiomech.2025.112832
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Initial tibial implant stability is important for successful long-term outcome after uncemented total ankle replacement (TAR). Tibia-implant interfacial micromotion is consequently a key variable used to evaluate implant performance using finite element analysis (FEA). Our goal was to investigate how bone material behavior assumptions influence FEA-predicted tibia-implant interfacial micromotions. Five tibia geometries and their corresponding density distributions were acquired from CT scans of TAR patients. The corresponding models were then virtually implanted with two tibial implant designs. FEA was used to simulate loadings from the stance phase of gait with line-to-line implantation. FEA predictions of peak micromotions and von Mises stress differences were compared across each patient-implant configuration, when incorporating elastic-plastic versus only linear elastic bone material behavior (5 tibias x 2 implant designs x 2 tibia material behaviors). We found that peak micromotions trended larger (up to 69 % greater) when elastic-plastic bone material behavior was incorporated, and that larger differences in peak micromotions were seen with larger differences in peak interfacial von Mises stresses between simulations incorporating elastic-plastic versus linear elastic bone material behavior (r = -0.73, p < 0.001). The larger peak micromotions when elastic-plastic bone material behavior was incorporated were strongly associated with how much interfacial bone plasticly deformed (r = 0.92, p < 0.001). These results imply that tibia-implant interfacial micromotions are underestimated when bone is assumed to behave only as a linear elastic material. Thus, the results from such FEA simulations should be interpreted with caution, as they are likely conservative in their estimates of micromotion.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[2]   Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models [J].
Berahmani, Sanaz ;
Janssen, Dennis ;
Verdonschot, Nico .
JOURNAL OF BIOMECHANICS, 2017, 61 :137-143
[3]   Osteoarthritis of the ankle: The role of arthroplasty [J].
Chou, Loretta B. ;
Coughlin, Michael T. ;
Hansen, Sigvard, Jr. ;
Haskell, Andrew ;
Lundeen, Gregg ;
Saltzman, Charles L. ;
Mann, Roger A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (05) :249-259
[4]   Influence of Tibial Component Design Features and Interference Fit on Implant-Bone Micromotion in Total Ankle Replacement: A Finite Element Study [J].
Clarke, Gabriel ;
Johnson, Joshua E. ;
Netto, Cesar de Cesar ;
Anderson, Donald D. .
FOOT & ANKLE INTERNATIONAL, 2024, 45 (12) :1414-1421
[5]   Risk Factors for Failure of Total Ankle Arthroplasty With a Minimum Five Years of Follow-up [J].
Cody, Elizabeth A. ;
Bejarano-Pineda, Lorena ;
Lachman, James R. ;
Taylor, Michel A. ;
Gausden, Elizabeth B. ;
DeOrio, James K. ;
Easley, Mark E. ;
Nunley, James A. .
FOOT & ANKLE INTERNATIONAL, 2019, 40 (03) :249-258
[6]   Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT [J].
Edwards, W. Brent ;
Schnitzer, Thomas J. ;
Troy, Karen L. .
JOURNAL OF BIOMECHANICS, 2013, 46 (10) :1655-1662
[7]  
Ghosh Ghosh R., 2024, Comput. Biol. Med., V177
[8]   Total ankle replacement leads to high revision rates in post-traumatic end-stage arthrosis [J].
Gramlich, Yves ;
Neun, Oliver ;
Klug, Alexander ;
Buckup, Johannes ;
Stein, Thomas ;
Neumann, Arvid ;
Fischer, Sebastian ;
Abt, Hans-Peter ;
Hoffmann, Reinhard .
INTERNATIONAL ORTHOPAEDICS, 2018, 42 (10) :2375-2381
[9]   10-year survival of total ankle arthroplasties A report on 780 cases from the Swedish Ankle Register [J].
Henricson, Anders ;
Nilsson, Jan-Ake ;
Carlsson, Ake .
ACTA ORTHOPAEDICA, 2011, 82 (06) :655-659
[10]   Enhanced stability of uncemented canine femoral components by bone ingrowth into the porous coatings [J].
Jasty, M ;
Bragdon, CR ;
Zalenski, E ;
OConnor, D ;
Page, A ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1997, 12 (01) :106-113