Influence of highly cross-linked polyethylene manufacturing characteristics on femoral head penetration in total hip arthroplasty A TEN-TO 22-YEAR FOLLOW-UP STUDY

被引:1
作者
Garcia-Rey, E. [1 ,3 ]
Saldana, L. [2 ,3 ]
机构
[1] Hosp Univ La Paz, IdiPAZ, Orthopaed Dept, Madrid 28046, Spain
[2] Hosp Univ La Paz, Bone Pathophysiol & Biomat Grp, IdiPAZ, Madrid, Spain
[3] Biomed Res Networking Ctr, Bioengn Biomat & Nanomed CIBER BBN, Madrid, Spain
关键词
MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR COMPONENT; MECHANICAL-PROPERTIES; REVISION SURGERY; WEAR RATES; LINER; REPLACEMENT; DISLOCATION; ORIENTATION; MINIMUM;
D O I
10.1302/0301-620X.107B5.BJJ-2024-1083.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Highly cross-linked polyethylene (HXLPE) has reduced wear and revision rates in total hip arthroplasty (THA) in the long term. However, the effect of HXLPE manufacturing characteristics on femoral head penetration has not yet been clearly defined. We report this single-institution study to investigate the clinical and radiological results of various HXLPE liners in THA. Methods Between January 2001 and December 2013, 904 uncemented THAs using HXLPE liners were performed at our institution. Seven different HXLPE liner types were identified: remelted (n = 3), annealed (n = 2), sequentially annealed (n = 1), and vitamin E diffused (n = 1). A total of 746 hips were available for a minimum follow-up of ten years. The linear femoral head penetration rate was measured at six weeks and at one, five, ten, and 15 years, applying the Dorr criteria to digitized radiographs, using the Roman v. 1 70 software package for analysis. Results No patient was revised due to wear or osteolysis. The mean total femoral head penetration ten years after THA ranged from 0.14 mm (SD 0.06) to 0.20 mm (SD 0.17) for all groups (p = 0.649). Femoral head penetration > 0.40 mm at ten years was observed in 27 (3.6%) hips. From one to 15 years after surgery, mean total penetration was 0.21 mm (SD 0.13) in components with an acetabular inclination > 50 degrees and 0.10 mm (SD 0.12) in those placed between 35 degrees and 50 degrees (p < 0.001). The radiological analysis did not detect osteolysis in any hip. Conclusion Although HXLPE characteristics can result in different wear performance in patients undergoing THA at a mean follow-up of 15 years, the clinical and radiological results were excellent in all groups. The position of the acetabular component can influence the femoral head penetration of modern HXLPEs.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 41 条
[1]   Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients A PROSPECTIVE RANDOMISED CONTROLLED TRIAL [J].
Atrey, A. ;
Ward, S. E. ;
Khoshbin, A. ;
Hussain, N. ;
Bogoch, E. ;
Schemitsch, E. H. ;
Waddell, J. P. .
BONE & JOINT JOURNAL, 2017, 99B (12) :1590-1595
[2]   Characteristics of highly cross-linked polyethylene wear debris in vivo [J].
Baxter, Ryan M. ;
MacDonald, Daniel W. ;
Kurtz, Steven M. ;
Steinbeck, Marla J. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) :467-475
[3]   Large articulations do not increase wear rates of thin second- generation highly cross- linked polyethylene liners at ten years [J].
Callary, S. A. ;
Sharma, D. K. ;
D'Apollonio, T. M. ;
Campbell, D. G. .
BONE & JOINT OPEN, 2023, 41 (11) :839-845
[4]   Polyethylene manufacturing characteristics have a major effect on the risk of revision surgery in cementless and hybrid total hip arthroplasties AN ANALYSIS OF THE NATIONAL JOINT REGISTRY OF ENGLAND, WALES, NORTHERN IRELAND AND THE ISLE OF MAN [J].
Davis, E. T. ;
Pagkalos, J. ;
Kopjar, B. .
BONE & JOINT JOURNAL, 2020, 102B (01) :90-101
[5]   Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years [J].
de Steiger, R. ;
Lorimer, M. ;
Graves, S. E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (15) :1281-1288
[6]   Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty A 10-Year Double-Blinded Randomized Controlled Trial [J].
Devane, Peter A. ;
Horne, James Geoffrey ;
Ashmore, Alexander ;
Mutimer, Jonathon ;
Kim, Woosung ;
Stanley, James .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20) :1703-1714
[7]   The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :6-16
[8]  
Divecha HM, 2021, BONE JOINT J, V103B, P1774, DOI [10.1302/0301-620X.103B12.BJJ-2021-0471.R1, 10.1302/0301-620X.103B12.BJJ-2021-0471]
[9]  
DORR LD, 1995, CLIN ORTHOP RELAT R, P191
[10]   Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years [J].
Dorr, LD ;
Wan, ZN ;
Shahrdar, C ;
Sirianni, L ;
Boutary, M ;
Yun, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1816-1821